目的探讨光谱CT定量增强参数对结直肠癌的诊断价值。方法对46例行腹盆部光谱CT三期增强的结直肠癌患者的能谱基数据进行处理,生成无水碘图、动脉增强分数(AEF)图及细胞外容积(ECV)图,分别测量肿瘤及正常肠壁的碘浓度(IC)、AEF及ECV值。...目的探讨光谱CT定量增强参数对结直肠癌的诊断价值。方法对46例行腹盆部光谱CT三期增强的结直肠癌患者的能谱基数据进行处理,生成无水碘图、动脉增强分数(AEF)图及细胞外容积(ECV)图,分别测量肿瘤及正常肠壁的碘浓度(IC)、AEF及ECV值。采用独立样本t检验及Mann-Whitney U检验进行组间比较,并采用ROC曲线评价其诊断效能。结果结直肠癌病变的AEF及IC值大于正常肠壁AEF值及IC值(0.338±0.122 vs 0.225±0.072,1.007±0.402 mg/mL vs 0.599±0.229 mg/mL,P<0.0001),ECV在结直肠癌病变与正常肠壁间的差异无统计学意义(P>0.999)。AEF、IC、ECV及三者联合诊断结直肠癌的ROC曲线下面积分别为0.806、0.797、0.671及0.842,其约登指数分别为0.565、0.565、0.326及0.609。三者联合诊断结直肠癌的截断值为0.660,敏感度为63.04%,特异性为97.83%,其逻辑回归方程为Y=13.75×AEF+16.30×ECV-6.70。结论光谱CT定量增强参数AEF、ECV及IC联合诊断对结直肠癌的诊断具有一定价值。展开更多
Recent accomplishment by the SWIP for the reduced activation ferritic/martensitic steel CLF-1 development has been reviewed. It's found that CLF- 1 steel has better room temperature tensile properties than Eurofer97 ...Recent accomplishment by the SWIP for the reduced activation ferritic/martensitic steel CLF-1 development has been reviewed. It's found that CLF- 1 steel has better room temperature tensile properties than Eurofer97 steel and has a fully martensitic microstructure.展开更多
目的采用MRI直方图纹理分析技术评估颞下颌关节紊乱病(temporomandibular disorder,TMD)患者的翼外肌功能变化。方法纳入2016年5月至2020年4月于解放军总医院海南医院放射科门诊就诊的28例TMD患者,男性15例,女性13例,年龄(26.2±12...目的采用MRI直方图纹理分析技术评估颞下颌关节紊乱病(temporomandibular disorder,TMD)患者的翼外肌功能变化。方法纳入2016年5月至2020年4月于解放军总医院海南医院放射科门诊就诊的28例TMD患者,男性15例,女性13例,年龄(26.2±12.1)岁(15~62岁);同时门诊招募13名颞下颌关节正常志愿者,男性6名,女性7名,年龄(23.5±3.3)岁(20~30)岁。所有受试者均进行双侧颞下颌关节MRI扫描,根据关节盘移位情况分为TMD关节盘位置正常侧(disc without displacement,TMD-DwoD)组(38侧)、TMD关节盘不可复性向前移位侧(disc displacement without reduction,TMD-DDwoR)组(18侧)、正常对照关节盘位置正常侧(normal control-Disc without displacement,NC-DwoD)组(26侧)。采用感兴趣区法测量闭口位时颞下颌关节翼外肌上肌腹与下肌腹面积、平均信号强度、信号强度变异系数、偏度及峰度等直方图纹理参数。结果翼外肌上腹TMD-DwoD组的面积[(67.36±30.23)mm2]显著小于NC-DwoD组[(91.42±45.01)mm2](P<0.05),与TMD-DDwoR组[(72.27±37.53)mm2]间差异无统计学意义(P>0.05);TMD-DwoD组及TMD-DDwoR组的平均信号强度(分别为304.20±29.90和315.06±40.20)均显著大于NC-DwoD组(269.79±25.54)(P<0.05);TMD-DwoD组变异系数(8.89±2.60)显著大于NC-DwoD组及TMD-DDwoR组(分别为6.76±1.82和7.63±1.62)(P<0.05);组间峰度、偏度差异均无统计学意义(P>0.05)。TMD-DwoD组及TMD-DDwoR组的翼外肌下腹平均信号强度(分别为286.69±23.48和275.98±30.55)显著大于NC-DwoD组(243.56±17.04)(P<0.05);TMD-DwoD组及TMD-DDwoR组变异系数(分别为9.96±2.24和10.25±1.96)均显著大于NC-DwoD组(8.49±1.94)(P<0.05);TMD-DwoD组及TMD-DDwoR组的偏度(分别为0.90±0.94和0.73±0.97)显著小于NC-DwoD组(1.40±1.03)(P<0.05);3组组间的翼外肌下腹面积、峰度差异无统计学意义(P>0.05)。结论MRI直方图纹理分析技术可初步作为颞下颌关节紊乱病患者翼外肌功能的评价工具。展开更多
文摘目的探讨光谱CT定量增强参数对结直肠癌的诊断价值。方法对46例行腹盆部光谱CT三期增强的结直肠癌患者的能谱基数据进行处理,生成无水碘图、动脉增强分数(AEF)图及细胞外容积(ECV)图,分别测量肿瘤及正常肠壁的碘浓度(IC)、AEF及ECV值。采用独立样本t检验及Mann-Whitney U检验进行组间比较,并采用ROC曲线评价其诊断效能。结果结直肠癌病变的AEF及IC值大于正常肠壁AEF值及IC值(0.338±0.122 vs 0.225±0.072,1.007±0.402 mg/mL vs 0.599±0.229 mg/mL,P<0.0001),ECV在结直肠癌病变与正常肠壁间的差异无统计学意义(P>0.999)。AEF、IC、ECV及三者联合诊断结直肠癌的ROC曲线下面积分别为0.806、0.797、0.671及0.842,其约登指数分别为0.565、0.565、0.326及0.609。三者联合诊断结直肠癌的截断值为0.660,敏感度为63.04%,特异性为97.83%,其逻辑回归方程为Y=13.75×AEF+16.30×ECV-6.70。结论光谱CT定量增强参数AEF、ECV及IC联合诊断对结直肠癌的诊断具有一定价值。
文摘Recent accomplishment by the SWIP for the reduced activation ferritic/martensitic steel CLF-1 development has been reviewed. It's found that CLF- 1 steel has better room temperature tensile properties than Eurofer97 steel and has a fully martensitic microstructure.
文摘目的采用MRI直方图纹理分析技术评估颞下颌关节紊乱病(temporomandibular disorder,TMD)患者的翼外肌功能变化。方法纳入2016年5月至2020年4月于解放军总医院海南医院放射科门诊就诊的28例TMD患者,男性15例,女性13例,年龄(26.2±12.1)岁(15~62岁);同时门诊招募13名颞下颌关节正常志愿者,男性6名,女性7名,年龄(23.5±3.3)岁(20~30)岁。所有受试者均进行双侧颞下颌关节MRI扫描,根据关节盘移位情况分为TMD关节盘位置正常侧(disc without displacement,TMD-DwoD)组(38侧)、TMD关节盘不可复性向前移位侧(disc displacement without reduction,TMD-DDwoR)组(18侧)、正常对照关节盘位置正常侧(normal control-Disc without displacement,NC-DwoD)组(26侧)。采用感兴趣区法测量闭口位时颞下颌关节翼外肌上肌腹与下肌腹面积、平均信号强度、信号强度变异系数、偏度及峰度等直方图纹理参数。结果翼外肌上腹TMD-DwoD组的面积[(67.36±30.23)mm2]显著小于NC-DwoD组[(91.42±45.01)mm2](P<0.05),与TMD-DDwoR组[(72.27±37.53)mm2]间差异无统计学意义(P>0.05);TMD-DwoD组及TMD-DDwoR组的平均信号强度(分别为304.20±29.90和315.06±40.20)均显著大于NC-DwoD组(269.79±25.54)(P<0.05);TMD-DwoD组变异系数(8.89±2.60)显著大于NC-DwoD组及TMD-DDwoR组(分别为6.76±1.82和7.63±1.62)(P<0.05);组间峰度、偏度差异均无统计学意义(P>0.05)。TMD-DwoD组及TMD-DDwoR组的翼外肌下腹平均信号强度(分别为286.69±23.48和275.98±30.55)显著大于NC-DwoD组(243.56±17.04)(P<0.05);TMD-DwoD组及TMD-DDwoR组变异系数(分别为9.96±2.24和10.25±1.96)均显著大于NC-DwoD组(8.49±1.94)(P<0.05);TMD-DwoD组及TMD-DDwoR组的偏度(分别为0.90±0.94和0.73±0.97)显著小于NC-DwoD组(1.40±1.03)(P<0.05);3组组间的翼外肌下腹面积、峰度差异无统计学意义(P>0.05)。结论MRI直方图纹理分析技术可初步作为颞下颌关节紊乱病患者翼外肌功能的评价工具。