期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于阻尼增强的梯度结构混凝土的阻尼特性和界面性能 被引量:4
1
作者 王信刚 吴链 卢峰 《建筑材料学报》 EI CAS CSCD 北大核心 2018年第5期780-785,共6页
基于梯度功能设计理念,制备了阻尼增强的梯度结构混凝土(GSCDE),同时采用自由振动法、抗压强度试验、显微硬度计、环境扫描电镜等方法和仪器来分别测试GSCDE的阻尼特性、抗压强度、界面显微硬度、界面微观结构.结果表明:随着阻尼层厚度... 基于梯度功能设计理念,制备了阻尼增强的梯度结构混凝土(GSCDE),同时采用自由振动法、抗压强度试验、显微硬度计、环境扫描电镜等方法和仪器来分别测试GSCDE的阻尼特性、抗压强度、界面显微硬度、界面微观结构.结果表明:随着阻尼层厚度比例的增加,GSCDE阻尼比随之递增,抗压强度则随之递减,立方体试件破坏时外观的损伤程度得到改善;GSCDE阻尼比可达3.96%以上,抗压强度可达55.0 MPa以上;与单层高性能混凝土(HPC)或单层高阻尼混凝土(HDC)相比,GSCDE能兼顾阻尼特性和强度,解决了高阻尼混凝土的组合减振结构一体化问题;在GSCDE阻尼层和结构层之间的界面结合区中,显微硬度从阻尼层到结构层均匀递增,2种混凝土相互渗透形成致密、均匀、稳定的整体;GSCDE中界面结合区的结合情况良好,有利于提高GSCDE的力学性能和阻尼特性. 展开更多
关键词 梯度结构混凝土 阻尼 界面 显微硬度 微观形貌
下载PDF
A Novel High Nitrogen Nickel-free Coronary Stents System: Evaluation in a Porcine Model 被引量:2
2
作者 ZHANG Bin CHEN Ming +4 位作者 ZHENG Bo wang xin gang wang Xi Ting FAN Yuan Yuan HUO Yong 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第4期289-294,共6页
Objective To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Methods Th... Objective To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Methods Three types of stents were randomly implanted in different coronary arteries of the same pig: 316L stainless steel BMS (316L-BMS) (n=12), novel high nitrogen nickel-free stents Grid A (NF-A-BMS) (n=12) and novel high nitrogen nickel-free stents Grid B (NF-B-BMS) (n=12). In total, eighteen animals underwent successful random placement of 36 oversized stents in the coronary arteries. Coronary angiography was performed after 36 d of stents implantation. Nine animals were respectively sacrificed after 14 d and 36 d for histomorphologic analysis. 〈br〉 Results Quantitative coronary angiography (QCA) showed similar luminal loss (LL) in the three groups:(0.21±0.17) mm for 316L-BMS, (0.16±0.12) mm for NF-A-BMS, (0.24±0.15) mm for NF-B-BMS (P=0.05). Histomorphomeric analysis after 15 d and 36 d revealed that there was also no significant difference among the three groups in neointimal area (NA) with similar injury scores respectively. High magnification histomorphologic examination showed similar inflammation scores in the three groups, but NF-A-BMS group had poorer endothelialization scores compared with NF-B-BMS group, 2.00±0.63 vs. 2.83±0.41 (P=0.015) at 15 d, which also could be proved by the scanning electron microscope. However, the difference could not been observed at 36 d. Conclusion The novel NF-BMS showed similar safety as 316L-BMS during the short-term study. NF-B-BMS had better endothelialization than NF-A-BMS and this may owe to the specific strut units. 展开更多
关键词 Austenitic steel Bare metal stent ENDOTHELIALIZATION RESTENOSIS Stent thrombosis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部