In this work, top and back gate characteristics of partially-depleted NMOS transistors with enclosed gate fabricated on SIMOX which is hardened by silicon ions implantation were studied under X-ray total-dose irradiat...In this work, top and back gate characteristics of partially-depleted NMOS transistors with enclosed gate fabricated on SIMOX which is hardened by silicon ions implantation were studied under X-ray total-dose irradiation of three bias conditions. It has been found experimentally that back gate threshold shift and leakage current were greatly reduced during irradiation for hardened transistors, comparing to control ones. It has been confirmed that the improvement of total-dose properties of SOI devices is attributed to the silicon nanocrystals (nanoclusters) in buried oxides introduced by ion implantation.展开更多
Background Now lung volume reduction surgery (LVRS) has become one of the most effective methods for the management of some cases of severe chronic obstructive pulmonary disease (COPD). We evaluated the mid-term e...Background Now lung volume reduction surgery (LVRS) has become one of the most effective methods for the management of some cases of severe chronic obstructive pulmonary disease (COPD). We evaluated the mid-term effects of LVRS on pulmonary function in patients with severe COPD. Methods Ten male patients with severe COPD aged 38-70 years underwent LVRS and their pulmonary function was assessed before, 3 months and 3 years after surgery. The spirometric and gas exchange parameters included residual volume, total lung capacity, inspiratory capacity, forced vital capacity, forced expiratory volume in one second, diffusion capacity for CO, and arterial blood gas. A 6-minute walk distance (6MWD) test was performed.Results As to preoperative assessment, most spirometric parameters and 6MWD were significantly improved after 3 months and slightly 3 years after LVRS. Gas exchange parameters were significantly improved 3 months after surgery, but returned to the preoperative levels after 3 years. Conclusions LVRS may significantly improve pulmonary function in patients with severe COPD indicating for LVRS. Mid-term pulmonary function 3 years after surgery can be decreased to the level at 3 months after surgery. Three years after LVRS, lung volume and pulmonary ventilation function can be significantly improved, but the improvement in gas exchange function was not significant.展开更多
For the design of the underwater laser detection system, the echo power equation of underwater target is derived, and the effects of water’s attenuation coefficient and incident angle on target’s echo power are anal...For the design of the underwater laser detection system, the echo power equation of underwater target is derived, and the effects of water’s attenuation coefficient and incident angle on target’s echo power are analyzed. The bidirectional reflection distribution function(BRDF) of the single-station model is used to study the reflection characteristics of the target. The influence of the correlation coefficients of specular and diffuse reflection components on the reflected light intensity of special axisymmetric targets is studied. The signal-to-noise ratio(SNR) values of three types of target under different surface BRDF are given. The simulation results show that the larger the attenuation coefficient is, the smaller the echo power received, and the incidence angle is closer to 90°, the echo power is equal to 0. A smaller surface slope or a larger diffuse reflected coefficient will cause a smaller reflected intensity.展开更多
Aiming at the problem of underwater polarized laser scattering caused by underwater suspended particles, the equivalent spherical particle Mie scattering theory simulation method is used to study the polarization char...Aiming at the problem of underwater polarized laser scattering caused by underwater suspended particles, the equivalent spherical particle Mie scattering theory simulation method is used to study the polarization characteristics of underwater scattered light. The relationship between underwater suspended particle characteristics and optical characteristics is analyzed, and the effects of particle size, polarization characteristics of incident light, and angle of incidence on the degree of polarization of forward and backward scattering light are studied. The results show that: When the incident light is natural light, the degree of polarization of scattered light is very low at the forward-scattering angle, which increases with the increase of the scattering angle, but changes frequently with the increase of the particle size. When the incident light is linearly polarized, the degree of linear polarization of the scattered light is related to the azimuth Angle. The degree of circular polarization is largely unaffected by particle size.展开更多
文摘In this work, top and back gate characteristics of partially-depleted NMOS transistors with enclosed gate fabricated on SIMOX which is hardened by silicon ions implantation were studied under X-ray total-dose irradiation of three bias conditions. It has been found experimentally that back gate threshold shift and leakage current were greatly reduced during irradiation for hardened transistors, comparing to control ones. It has been confirmed that the improvement of total-dose properties of SOI devices is attributed to the silicon nanocrystals (nanoclusters) in buried oxides introduced by ion implantation.
文摘Background Now lung volume reduction surgery (LVRS) has become one of the most effective methods for the management of some cases of severe chronic obstructive pulmonary disease (COPD). We evaluated the mid-term effects of LVRS on pulmonary function in patients with severe COPD. Methods Ten male patients with severe COPD aged 38-70 years underwent LVRS and their pulmonary function was assessed before, 3 months and 3 years after surgery. The spirometric and gas exchange parameters included residual volume, total lung capacity, inspiratory capacity, forced vital capacity, forced expiratory volume in one second, diffusion capacity for CO, and arterial blood gas. A 6-minute walk distance (6MWD) test was performed.Results As to preoperative assessment, most spirometric parameters and 6MWD were significantly improved after 3 months and slightly 3 years after LVRS. Gas exchange parameters were significantly improved 3 months after surgery, but returned to the preoperative levels after 3 years. Conclusions LVRS may significantly improve pulmonary function in patients with severe COPD indicating for LVRS. Mid-term pulmonary function 3 years after surgery can be decreased to the level at 3 months after surgery. Three years after LVRS, lung volume and pulmonary ventilation function can be significantly improved, but the improvement in gas exchange function was not significant.
基金supported by the National Natural Science Foundation of China(No.51879221)the National Natural Science Youth Foundation of China(No.61404362)+1 种基金the Fundamental Research Funds of Shen Zhen Government(No.JCYJ20170306152455554)the Key Laboratory Foundation(No.D5120190034).
文摘For the design of the underwater laser detection system, the echo power equation of underwater target is derived, and the effects of water’s attenuation coefficient and incident angle on target’s echo power are analyzed. The bidirectional reflection distribution function(BRDF) of the single-station model is used to study the reflection characteristics of the target. The influence of the correlation coefficients of specular and diffuse reflection components on the reflected light intensity of special axisymmetric targets is studied. The signal-to-noise ratio(SNR) values of three types of target under different surface BRDF are given. The simulation results show that the larger the attenuation coefficient is, the smaller the echo power received, and the incidence angle is closer to 90°, the echo power is equal to 0. A smaller surface slope or a larger diffuse reflected coefficient will cause a smaller reflected intensity.
基金supported by the National Natural Science Foundation of China(No.61404362)。
文摘Aiming at the problem of underwater polarized laser scattering caused by underwater suspended particles, the equivalent spherical particle Mie scattering theory simulation method is used to study the polarization characteristics of underwater scattered light. The relationship between underwater suspended particle characteristics and optical characteristics is analyzed, and the effects of particle size, polarization characteristics of incident light, and angle of incidence on the degree of polarization of forward and backward scattering light are studied. The results show that: When the incident light is natural light, the degree of polarization of scattered light is very low at the forward-scattering angle, which increases with the increase of the scattering angle, but changes frequently with the increase of the particle size. When the incident light is linearly polarized, the degree of linear polarization of the scattered light is related to the azimuth Angle. The degree of circular polarization is largely unaffected by particle size.