Some methods of capillary gas chromatography, such as GC, GC-MS,GC-FT-IR, are used to analyze the products of thymine irradiated by 18O8+ ion beam in N2O saturated aqueous solution. From the results of GC-MS the molec...Some methods of capillary gas chromatography, such as GC, GC-MS,GC-FT-IR, are used to analyze the products of thymine irradiated by 18O8+ ion beam in N2O saturated aqueous solution. From the results of GC-MS the molecular weight of products can be determined, and from the results of GC-FT-IR some molecular structure information of products can be obtained. By this way the products,5,6-Dihydrothyndne, 5-Hydroxyl-5-Methylhydantoin, 5-Hydroxyl-6-Hydrothymine, 5-Hydro-6-Hydroxylthymine, 5-Hydroxymethyluracil, Trans-Thymine glycol, Cis-Thymine glycol and dimers are determined without separation of them from samples. Though these products are as same as those products of thymine irradiated by γ rays in N2O saturated aqueous solution, the mechanism of thymine irradiated by heavy ion beam in aqueous solution is different from that by γ rays. The main products of thymine irradiated by 18O8+ ion beam in N2O saturated aqueous solution are hydroxyl adducts at 5-6 band of thymine, while the main products of thymine irradiated by γ ray in N2O saturated aqueous solution are dimers of thymine.展开更多
A calibration experiment of CR-39 with Ne ions for space heavy ion identification has been performed. It is necessary for studying the mechanism of mutation breeding induced by space particles. In the experiment, 20Ne...A calibration experiment of CR-39 with Ne ions for space heavy ion identification has been performed. It is necessary for studying the mechanism of mutation breeding induced by space particles. In the experiment, 20Ne ion beams with nominal energy of 230 MeV/u and density of 500 cm-2 supplied by HIMAC were used to irradiate a stack of 25 pieces of CR-39 films vertically. After degraded by a binary filter,展开更多
文摘Some methods of capillary gas chromatography, such as GC, GC-MS,GC-FT-IR, are used to analyze the products of thymine irradiated by 18O8+ ion beam in N2O saturated aqueous solution. From the results of GC-MS the molecular weight of products can be determined, and from the results of GC-FT-IR some molecular structure information of products can be obtained. By this way the products,5,6-Dihydrothyndne, 5-Hydroxyl-5-Methylhydantoin, 5-Hydroxyl-6-Hydrothymine, 5-Hydro-6-Hydroxylthymine, 5-Hydroxymethyluracil, Trans-Thymine glycol, Cis-Thymine glycol and dimers are determined without separation of them from samples. Though these products are as same as those products of thymine irradiated by γ rays in N2O saturated aqueous solution, the mechanism of thymine irradiated by heavy ion beam in aqueous solution is different from that by γ rays. The main products of thymine irradiated by 18O8+ ion beam in N2O saturated aqueous solution are hydroxyl adducts at 5-6 band of thymine, while the main products of thymine irradiated by γ ray in N2O saturated aqueous solution are dimers of thymine.
文摘A calibration experiment of CR-39 with Ne ions for space heavy ion identification has been performed. It is necessary for studying the mechanism of mutation breeding induced by space particles. In the experiment, 20Ne ion beams with nominal energy of 230 MeV/u and density of 500 cm-2 supplied by HIMAC were used to irradiate a stack of 25 pieces of CR-39 films vertically. After degraded by a binary filter,