An x-ray laser shadowgraphy experiment was conducted on Xingguang-Ⅱ laser facility in 1996.A multi-layer spherical mirror was used as an imaging element and a high sensitivity CCD camera as a detector.We measured the...An x-ray laser shadowgraphy experiment was conducted on Xingguang-Ⅱ laser facility in 1996.A multi-layer spherical mirror was used as an imaging element and a high sensitivity CCD camera as a detector.We measured the near-field image of the Ti x-ray laser beam.With a Ti x-ray laser beam as a backlight source,we obtained a clear CU mesh image,demonstrating the potential as advanced diagnostic measurements to study high density plasmas in inertial confinement fusion research.展开更多
For prompt physical diagnosis, several types of subnanosecond current mode detectors have been developed, including scintillator detectors with large linear output current, GaAs:Cr and InP:Fe photoconductor detectors(...For prompt physical diagnosis, several types of subnanosecond current mode detectors have been developed, including scintillator detectors with large linear output current, GaAs:Cr and InP:Fe photoconductor detectors(PCD), and X-ray diodes(XRD), etc. The characteristic of scintillation light of BaF2 crystal doped with La and of plastic scintillator ST1422 with slow component quencher are described. As for the photoconductor detectors, the main performance of neutron damaged GaAs:Cr and InP:Fe were studied. In addition, the spectral response of an XRD with coaxial leading-out end was also studied. These detectors have been successfully applied to nuclear test diagnosis and ICF research.展开更多
基金Supported by the National High Technique 863-410 Project.
文摘An x-ray laser shadowgraphy experiment was conducted on Xingguang-Ⅱ laser facility in 1996.A multi-layer spherical mirror was used as an imaging element and a high sensitivity CCD camera as a detector.We measured the near-field image of the Ti x-ray laser beam.With a Ti x-ray laser beam as a backlight source,we obtained a clear CU mesh image,demonstrating the potential as advanced diagnostic measurements to study high density plasmas in inertial confinement fusion research.
文摘For prompt physical diagnosis, several types of subnanosecond current mode detectors have been developed, including scintillator detectors with large linear output current, GaAs:Cr and InP:Fe photoconductor detectors(PCD), and X-ray diodes(XRD), etc. The characteristic of scintillation light of BaF2 crystal doped with La and of plastic scintillator ST1422 with slow component quencher are described. As for the photoconductor detectors, the main performance of neutron damaged GaAs:Cr and InP:Fe were studied. In addition, the spectral response of an XRD with coaxial leading-out end was also studied. These detectors have been successfully applied to nuclear test diagnosis and ICF research.