期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
HLA-B27阳性与阴性葡萄膜炎患者外周血中炎症因子表达研究 被引量:2
1
作者 王洪亚 郑文 +2 位作者 戴永刚 周玮琰 孙进学 《国际眼科杂志》 CAS 北大核心 2022年第9期1559-1563,共5页
目的:通过分析比较人白细胞抗原-B27(HLA-B27)阳性及阴性葡萄膜炎患者外周血中炎症因子的表达变化情况,探讨其相关性。方法:回顾性研究。选取2020-01/2022-04我院初诊为葡萄膜炎的患者76例,采集静脉血分离有核细胞,用流式细胞术(直接免... 目的:通过分析比较人白细胞抗原-B27(HLA-B27)阳性及阴性葡萄膜炎患者外周血中炎症因子的表达变化情况,探讨其相关性。方法:回顾性研究。选取2020-01/2022-04我院初诊为葡萄膜炎的患者76例,采集静脉血分离有核细胞,用流式细胞术(直接免疫荧光法)检测HLA-B27,分成HLA-B27阳性组(≥90%)35例和HLA-B27阴性组(≤5%)41例。提取全血RNA,用RT-qPCR方法检测并比较白细胞介素-1β(IL-1β)、白细胞介素-6(IL-6)、白细胞介素-10(IL-10)、蛋白酶激活受体2(PAR2)、肿瘤坏死因子-α(TNF-α)、白细胞介素增强因子-3(ILF3)mRNA表达。结果:两组患者IL-1β、IL-10、PAR2、TNF-αmRNA表达均无差异(均P>0.05)。HLA-B27阳性组患者IL-6 mRNA较HLA-B27阴性组升高,ILF3 mRNA较HLA-B27阴性组降低(均P<0.05)。结论:HLA-B27阳性相关的葡萄膜炎患者外周血中炎性指标IL-6表达显著升高,ILF3较HLA-B27阴性组表达下降,可作为其辅助诊疗指标。 展开更多
关键词 葡萄膜炎 人白细胞抗原-27(HLA-B27) 炎症因子
下载PDF
Inductively Coupled Plasma Mass Spectrometry as a Reference Method to Evaluate Serum Calcium Measurement Bias and the Commutability of Processed Materials during Routine Measurements 被引量:1
2
作者 Hai-Jian Zhao Meng-Lei Ge +6 位作者 Yin Yan Tian-Jiao Zhang Jie Zeng wei-yan zhou Yu-Fei Wang Qing-Hui Meng Chuan-Bao Zhang 《Chinese Medical Journal》 SCIE CAS CSCD 2018年第13期1584-1590,共7页
Background: Measuring total serum calcium is important for the diagnosis of diseases. Currently, results from commercial kits for calcium measurement are variable. Generally, the performance of serum calcium measurem... Background: Measuring total serum calcium is important for the diagnosis of diseases. Currently, results from commercial kits for calcium measurement are variable. Generally, the performance of serum calcium measurements is monitored by external quality assessment (EQA) or proficiency testing schemes. However, the commutability of the EQA samples and calibrators is often unknown, which limits the effectiveness of EQA schemes. The aim of this study was to evaluate the bias of serum calcium measurements and the commutability of processed materials. Methods: Inductively coupled plasma mass spectrometry was applied as a comparative method, and 14 routine methods were chosen as test methods. Forty-eight serum samples from individual patients and 25 processed materials were quantified. A scatter plot was generated from patient samples, and 95% prediction intervals were calculated to evaluate the commutability of the processed materials and measurement bias at three concentration levels was used to determine the accuracy of routine assays. Results: All assays showed high precision (total coefficient of variation [CV] 〈2.26%) and correlation coefficients (r 〉 0.99). For all assays, the mean bias for the 48 patient samples ranged from 0.13 mmol/L to 0.00 mmol/L (-5.61 0.01%), and the ranges for the three concentrations were 0.10-0.04 mmoUL (-5.71-2.35%), -0.14-0.01 mmol/L (-5.80-0.30%), and -0.19-0.04 mmol/L (-6.24-1.22%). The EQA samples, calibrators, and animal sera exhibited matrix effects in some assays; human serum pools were commutable in all assays; certificate reference materials were commutable in most assays, and only GBW09152 exhibited a matrix effect in one assay: and aqueous reference materials exhibited matrix effects in most assays. Conclusions: Biases for most assays were within the acceptable range, although the accuracy of some assays needs improvement. Human serum pools prepared from patient samples were commutable, and the other tested materials exhibited a matrix effect. 展开更多
关键词 Calibration Bias COMMUTABILITY Inductively Coupled Plasma Mass Spectrometry Matrix Effect Serum Calcium
原文传递
上一页 1 下一页 到第