This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary...This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary public hospitals from 2007 to 2017 were investigated and seven critical categories,namely indoor air,work surface,hand hygiene,ultraviolet(UV)irradiation intensity,use of disinfectants,sterilization of medical items,and effects of steam sterilizer,were monitored.The average qualified rates were(94.74±3.54)%(810/855),(97.25±1.65)%(1876/1929),(87.57±4.60)%(2508/2864),(95.00±4.50)%(1196/1259),and(98.76±1.14)%(1599/1619)for indoor air,work surface,hand hygiene,UV irradiation intensity,and sterilization of medical items,respectively.In terms of other categories,few samples were not qualified:3/1575 for use of disinfectants and 1/243 for effects of steam sterilizer.The hospital disinfection monitoring and supervision program effectively improved the effectiveness of disinfection.Routine monitoring and supervision must be conducted to ensure a safe hospital treatment environment.展开更多
A trigonometric series expansion method and two similar modified methods for the Orr-Sommerfeld equation are presented. These methods use the trigonometric series expansion with an auxiliary function added to the high...A trigonometric series expansion method and two similar modified methods for the Orr-Sommerfeld equation are presented. These methods use the trigonometric series expansion with an auxiliary function added to the highest order derivative of the unknown function and generate the lower order derivatives through successive integra- tions. The proposed methods are easy to implement because of the simplicity of the chosen basis functions. By solving the plane Poiseuille flow (PPF), plane Couette flow (PCF), and Blasius boundary layer flow with several homogeneous boundary conditions, it is shown that these methods yield results with the same accuracy as that given by the conventional Chebyshev collocation method but with better robustness, and that ob- tained by the finite difference method but with fewer modal number.展开更多
We extend the impulse theory for unsteady aerodynamics, from its classic global form to finite-domain formulation, then to a minimum-domain version for discrete wake. Each extension has been confirmed numerically. The...We extend the impulse theory for unsteady aerodynamics, from its classic global form to finite-domain formulation, then to a minimum-domain version for discrete wake. Each extension has been confirmed numerically. The minimum-domain theory indicates that the numerical finding of Li and Lu(2012) is of general significance: The entire force is completely determined by only the time rate of impulse of those vortical structures still connecting to the body, along with the Lamb-vector integral thereof that captures the contribution of all the rest disconnected vortical structures.展开更多
文摘This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary public hospitals from 2007 to 2017 were investigated and seven critical categories,namely indoor air,work surface,hand hygiene,ultraviolet(UV)irradiation intensity,use of disinfectants,sterilization of medical items,and effects of steam sterilizer,were monitored.The average qualified rates were(94.74±3.54)%(810/855),(97.25±1.65)%(1876/1929),(87.57±4.60)%(2508/2864),(95.00±4.50)%(1196/1259),and(98.76±1.14)%(1599/1619)for indoor air,work surface,hand hygiene,UV irradiation intensity,and sterilization of medical items,respectively.In terms of other categories,few samples were not qualified:3/1575 for use of disinfectants and 1/243 for effects of steam sterilizer.The hospital disinfection monitoring and supervision program effectively improved the effectiveness of disinfection.Routine monitoring and supervision must be conducted to ensure a safe hospital treatment environment.
基金supported by the National Natural Science Foundation of China(Nos.11221062,11521091,and 91752203)
文摘A trigonometric series expansion method and two similar modified methods for the Orr-Sommerfeld equation are presented. These methods use the trigonometric series expansion with an auxiliary function added to the highest order derivative of the unknown function and generate the lower order derivatives through successive integra- tions. The proposed methods are easy to implement because of the simplicity of the chosen basis functions. By solving the plane Poiseuille flow (PPF), plane Couette flow (PCF), and Blasius boundary layer flow with several homogeneous boundary conditions, it is shown that these methods yield results with the same accuracy as that given by the conventional Chebyshev collocation method but with better robustness, and that ob- tained by the finite difference method but with fewer modal number.
基金supported by the National Natural Science Foundation of China(Grant Nos.10921202,11221062,11521091 and 11472016)
文摘We extend the impulse theory for unsteady aerodynamics, from its classic global form to finite-domain formulation, then to a minimum-domain version for discrete wake. Each extension has been confirmed numerically. The minimum-domain theory indicates that the numerical finding of Li and Lu(2012) is of general significance: The entire force is completely determined by only the time rate of impulse of those vortical structures still connecting to the body, along with the Lamb-vector integral thereof that captures the contribution of all the rest disconnected vortical structures.