期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Rapid detection of high-risk HPV16 and HPV18 based on microchip electrophoresis 被引量:4
1
作者 Zhaoxuan Fan Xiao Feng +2 位作者 weifei zhang Xueji zhang Jin-Ming Lin 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第4期329-333,共5页
Researches on detection of human papillomavirus(HPV)high-risk samples were carried out by polymerase chain reaction(PCR)coupled with microchip electrophoresis(MCE).Herein,we introduced a simple,rapid,automated method ... Researches on detection of human papillomavirus(HPV)high-risk samples were carried out by polymerase chain reaction(PCR)coupled with microchip electrophoresis(MCE).Herein,we introduced a simple,rapid,automated method for detecting high-risk samples HPV16 and HPV18.In this research,general primers were initially selected to obtain sufficient detectable yield by PCR to verify feasibility of MCM method for HPV detection,then type-specific primers were further used to evaluate the specificity of MCE method.The results indicated MCE method was capable of specifically detecting high-risk HPV16 and HPV18,and also enabled simultaneous detection of multiplex samples.This MCE method described here has been successfully applied to HPV detection and displayed excellent reliability demonstrating by sequencing results.The inherent capability of MCE facilitated HPV detection conducted in a small chip with automated,high throughput,massive parallelized analysis.We envision that MCE method will definitely pave a way for clinical diagnosis,and even on-site screening of cervical cancer. 展开更多
关键词 Human papillomavirus DNA analysis Polymerase chain reaction Microchip electrophoresis DETECTION
下载PDF
Shell microparticles of morphology controlled and inner-modified hole from sequential inkjet-printed double emulsions 被引量:1
2
作者 weifei zhang Nan Li +3 位作者 Yong zhang Hulie Zeng Katsumi Uchiyama Jin-Ming Lin 《Science China Chemistry》 SCIE EI CAS CSCD 2018年第11期1465-1469,共5页
This article presents sequential inkjet-based method to produce double emulsions as templates to fabricate morphology-controlled and inner-modified hole-shell microparticles. This sequential printing strategy for prod... This article presents sequential inkjet-based method to produce double emulsions as templates to fabricate morphology-controlled and inner-modified hole-shell microparticles. This sequential printing strategy for producing double emulsions circumvents complex wettability modification of the microchannels in lithography-based microfluidic device and largely saves the reagent in comparison to the coaxial two-phase jet in glass capillary. The formation of hole-shell structures is attributed to the diffusion of solvent out of droplets into butanol at the interface between oil and extract phase. The change of hole size is controlled by different diffusion rate, which is determined by changing the volume ratio of butanol and alcohol in extract phase.This presented flexible method can fabricate some functionalized microparticles in our future work. 展开更多
关键词 INKJET 率控制 乳剂 打印 修改 形态学 轰炸 平版印刷术
原文传递
Recent progress on microfluidic biosensors for rapid detection of pathogenic bacteria 被引量:1
3
作者 Gaowa Xing weifei zhang +2 位作者 Nan Li Qiaosheng Pu Jin-Ming Lin 《Chinese Chemical Letters》 SCIE CAS CSCD 2022年第4期1743-1751,共9页
Rapid on-site detection of pathogenic bacteria with high sensitivity and specificity is becoming an urgent need in public health assurance, medical diagnostics, environmental monitoring, and food safety fields. Despit... Rapid on-site detection of pathogenic bacteria with high sensitivity and specificity is becoming an urgent need in public health assurance, medical diagnostics, environmental monitoring, and food safety fields. Despite being reliable and widely used, the existing methods of bacteria detection are cumbersome and time-consuming, which is not conducive to field detection. Microfluidic lab-on-a-chip technology has provided a detective tool for various analytes, due to its miniaturization, portability and low reagent consumption. Within this progress report, advances in the bacteria detection using microfluidic biosensors were discussed. Typical methods for pathogenic bacteria capture, separation and detection were introduced respectively in the first part. Then key applications of microfluidic biosensor-based rapid bacteria detection were presented. Finally, we made a conclusion and discussed possible research prospects in aspects of microfluidic biosensors for rapid detection of pathogenic bacteria. 展开更多
关键词 Microfluidic chip Biosensors Pathogenic bacteria Rapid detection
原文传递
Di-4-ANEPPDHQ probes the response of lipid packing to the membrane tension change in living cells
4
作者 Nan Li weifei zhang +1 位作者 Haifeng Lin Jin-Ming Lin 《Chinese Chemical Letters》 SCIE CAS CSCD 2022年第3期1377-1380,共4页
Membrane tension plays a significant role in many cellular processes including cell adhesion, migration and spreading. Despite the importance of membrane tension, it remains difficult to measure in vivo. Recently, the... Membrane tension plays a significant role in many cellular processes including cell adhesion, migration and spreading. Despite the importance of membrane tension, it remains difficult to measure in vivo. Recently, the development of non-invasive fluorescent probes have made great progress, especially excitedstate deplanarization in molecular rotors has been applied to image membrane tension in living cells.Nevertheless, an intrinsic limitation of such kind of probe is that they depend on the lipid packing, and how the lipid packing responds to the membrane tension change remains unclear. Therefore, in this work,we used a polarity-sensitive membrane probe to investigate the possible response mechanism of lipid packing to the change of membrane tension that was regulated by osmotic shocks. The results showed that an increase in membrane tension could stretch the lipids apart with large displacements, and this change was not homogeneous on the whole membrane, instead, increase of membrane tension induced phase separation. 展开更多
关键词 Lipid packing Membrane tension Osmotic shocks Polarity-sensitive probe Phase separation
原文传递
Determination of polybrominated diphenyl ethers in river water by combination of liquid–liquid extraction and gas chromatography–mass spectrometry
5
作者 weifei zhang Xuexia Lin +2 位作者 Hai-Fang Li Zhihua Wang Jin-Ming Lin 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第9期1225-1229,共5页
In this work, a reliable and sensitive method for detecting polybrominated diphenyl ethers (PBDEs) has been developed by the combination of liquid-liquid extraction and gas chromatography-mass spectrometry. PBDEs we... In this work, a reliable and sensitive method for detecting polybrominated diphenyl ethers (PBDEs) has been developed by the combination of liquid-liquid extraction and gas chromatography-mass spectrometry. PBDEs were extracted from a large volume of water by liquid-liquid extraction and purified by silica gel chromatography. In order to reduce the deviation, dibromobiphenyl was exploited as the internal standard to minimize differences among the injections. The quantification was performed using an external standard. Good linear correlation coefficients (〉0.991) and a wide linearity range ( 1,0- 500.0 ng/L) indicated the steadiness of the proposed method. Moreover, the satisfactory recovery (〉75%) suggested that successful determination of PBDEs in river water had been achieved. Furthermore, the deduction behavior of PBDEs in river water could be inferred according to the results. 展开更多
关键词 Polybrominated diphenyl ethers Dibromobiphenyl GC-MS Liquid-liquid extraction
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部