期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Behavior of calcium oxalate in sodium aluminate solutions 被引量:3
1
作者 Gui-hua LIU wen-bo dong +3 位作者 Tian-gui QI Qiu-sheng ZHOU Zhi-hong PENG Xiao-bin LI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2017年第8期1879-1888,共10页
The stability of calcium oxalate is critical for the removal of sodium oxalate from sodium aluminate solutions.This studyinvestigated the behavior of calcium oxalate in sodium aluminate solution containing sodium carb... The stability of calcium oxalate is critical for the removal of sodium oxalate from sodium aluminate solutions.This studyinvestigated the behavior of calcium oxalate in sodium aluminate solution containing sodium carbonate.Results show that calciumoxalate can be converted to tricalcium aluminate hydrate(TCA)and calcium carbonate in sodium aluminate solution and sodiumcarbonate solution,respectively.Elevating temperature,extending residence time,or increasing caustic soda concentration enhancesthe conversion ratio of calcium oxalate in sodium aluminate solution;as a consequence,anti-causticisation occurs.Stability ofcalcium-containing compounds in sodium aluminate solution containing sodium carbonate differs from that in sodium aluminatesolution or sodium carbonate solution.Na2CO3in aluminate solution accelerates the transformation of calcium oxalate;thus,aluminais lost because of4CaO·Al2O3·CO2·11H2O and TCA formation.Calcium carbonate,4CaO·Al2O3·CO2·11H2O and calcium oxalatecan change into TCA in sodium aluminate solution at elevated temperature.Calcium oxalate remains relatively stable in dilutealuminate solution within a short residence time at low temperature.Thus,a novel process for removal of sodium oxalate by limecausticisation was presented and employed in an alumina refinery in China. 展开更多
关键词 calcium oxalate sodium aluminate solution sodium carbonate lime causticisation activity coefficient
下载PDF
Calibration of Camera with Large Field-of-View Based on Flexible Planar Target
2
作者 Ju Huo wen-bo dong +1 位作者 Ning Yang Wu-Kang Lin 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第4期14-20,共7页
For high precision calibration of camera with large field-of-view,massive calibration points will be needed if traditional methods are selected,which makes the calibration complex and time-consuming.In order to solve ... For high precision calibration of camera with large field-of-view,massive calibration points will be needed if traditional methods are selected,which makes the calibration complex and time-consuming.In order to solve this problem,a calibration method based on flexible planar target is proposed.In this method,distortion factor is firstly acquired by the invariance of cross ratio,and existing feature points are adjusted with the distortion factor.Then,a large number of points that will be used for the calibration are constructed with the adjusted feature points.Simultaneously,Tsai method is modified so as to reduce the complexity of calibration,which makes the process linear.The simulation and real experiments show that the method proposed in this paper is simple,linear,accurate and robust,and the precision of this method is close to that of Tsai method using abundant points.The method can satisfy the requirement of high precision calibration for camera with large field-of-view. 展开更多
关键词 large field-of-view calibration distortion factor flexible planar target linear two-step method
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部