The total coal consumption in China is on the rise.The characteristics of CO2 and SO2 emissions in the whole process of coal processing and utilization in China are worthy of study.Based on the five links of the whole...The total coal consumption in China is on the rise.The characteristics of CO2 and SO2 emissions in the whole process of coal processing and utilization in China are worthy of study.Based on the five links of the whole process of coal production and utilization,including coal production,raw coal processing,logistics and transportation,conversion and utilization and resource utilization,this paper summarized and analyzed the energy consumption and pollutant emission sources of these five links,combined with the US Environmental Protection Agency’s AP-42 method and IPCC method,to calculate total pollutant discharge and emission factors,where the emission factors were corrected by conversion efficiency.At the same time,uncertainty analysis is performed about CO2 and SO2 emissions.The results showed that CO2 emissions were 3.657 billion tons,and emission reductions were 61 million tons,and SO2 emissions were 4,844,500 tons,and emission reductions were 10.3595 million tons in 2015.展开更多
With the aim of controlling the problem of fine particles in the flue gas of lead-zinc smelting,a low-temperature plasma-electrocoagulation and electric bag composite dedusting experimental platform was designed by co...With the aim of controlling the problem of fine particles in the flue gas of lead-zinc smelting,a low-temperature plasma-electrocoagulation and electric bag composite dedusting experimental platform was designed by combining electrocoagulation and electric bag composite dust removal technology based on the research of low-temperature plasma technology.Firstly,the properties of fine particles in flue gas from lead-zinc smelting were analyzed,and the effects of input voltage,filter wind speed,dust concentration,and pulse-jet ash-cleaning cycle on the dust collection efficiency of the integrated device were studied.Then,the energy efficiency of the integrated technology was analyzed,and the control mechanism of the fine particles was revealed.The experimental results show that the integrated technology of low-temperature plasma-electrocoagulation and electric bag composite dust removal achieves a fine particle removal efficiency of more than 99.99%and the energy consumption per unit mass of the dust is only 0.008 k W·h/g.The integrated technology has broad application prospects and farreaching practical significance for the lead-zinc smelting industry to achieve ultra-low emission targets for flue gas and achieve energy-saving and emission reduction effects.展开更多
In the original publication,there were few amendments to be made:In Abstract,"4,844,500 tons"should be changed into"4.4845 million tons".The ordinate unit of Fig.1"million tons"should be ...In the original publication,there were few amendments to be made:In Abstract,"4,844,500 tons"should be changed into"4.4845 million tons".The ordinate unit of Fig.1"million tons"should be changed into"billion tons".In Introduction Section,"China’s total coal production increased from 2.57 million tons in 2006 to 3.52 million tons in 2017."should be changed into"China’s total coal production increased from 2.57 billion tons in 2006 to 3.52 billion tons in 2017."展开更多
基金Supported by the Major Science and Technology Projects of Shanxi Province(No.20181102017)the Open Project Program of State Key Laboratory of Petroleum Pollution Control(No.PPC2017010)+1 种基金CNPC Research Institute of Safety and Environmental Technologythe Fundamental Research Funds for the Central Universities(No.2009QH03).
文摘The total coal consumption in China is on the rise.The characteristics of CO2 and SO2 emissions in the whole process of coal processing and utilization in China are worthy of study.Based on the five links of the whole process of coal production and utilization,including coal production,raw coal processing,logistics and transportation,conversion and utilization and resource utilization,this paper summarized and analyzed the energy consumption and pollutant emission sources of these five links,combined with the US Environmental Protection Agency’s AP-42 method and IPCC method,to calculate total pollutant discharge and emission factors,where the emission factors were corrected by conversion efficiency.At the same time,uncertainty analysis is performed about CO2 and SO2 emissions.The results showed that CO2 emissions were 3.657 billion tons,and emission reductions were 61 million tons,and SO2 emissions were 4,844,500 tons,and emission reductions were 10.3595 million tons in 2015.
基金supported by the State Key Laboratory of Organic Geochemistry,GIGCAS(No.SKLOG-201909)the Fundamental Research Funds for the Central Universities(2009QH03)funded by the Open Foundation of Shaanxi Key Laboratory of Lacustrine Shale Gas Accumulation and Exploitation(under planning).
文摘With the aim of controlling the problem of fine particles in the flue gas of lead-zinc smelting,a low-temperature plasma-electrocoagulation and electric bag composite dedusting experimental platform was designed by combining electrocoagulation and electric bag composite dust removal technology based on the research of low-temperature plasma technology.Firstly,the properties of fine particles in flue gas from lead-zinc smelting were analyzed,and the effects of input voltage,filter wind speed,dust concentration,and pulse-jet ash-cleaning cycle on the dust collection efficiency of the integrated device were studied.Then,the energy efficiency of the integrated technology was analyzed,and the control mechanism of the fine particles was revealed.The experimental results show that the integrated technology of low-temperature plasma-electrocoagulation and electric bag composite dust removal achieves a fine particle removal efficiency of more than 99.99%and the energy consumption per unit mass of the dust is only 0.008 k W·h/g.The integrated technology has broad application prospects and farreaching practical significance for the lead-zinc smelting industry to achieve ultra-low emission targets for flue gas and achieve energy-saving and emission reduction effects.
文摘In the original publication,there were few amendments to be made:In Abstract,"4,844,500 tons"should be changed into"4.4845 million tons".The ordinate unit of Fig.1"million tons"should be changed into"billion tons".In Introduction Section,"China’s total coal production increased from 2.57 million tons in 2006 to 3.52 million tons in 2017."should be changed into"China’s total coal production increased from 2.57 billion tons in 2006 to 3.52 billion tons in 2017."