With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the c...With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the construction investment. In this paper, the upstream finite element method was expanded to calculate the total electric field of same tower multi-circuit DC lines converted from double-circuit AC lines, and the validity of the algorithm was confirmed by experiments. Taking a DC line converted from a typical same tower 500 kV double-circuit AC transmission line as an example, the surface electric field and the ground total electric field in different pole conductor arrangement schemes were calculated and analyzed, and the critical height of pole conductors for DC lines in residential and non-residential area were determined. Then, the corridor width of DC and AC lines at critical height in residential and non-residential areas before and after AC-DC line transformation were compared. The results indicate that for DC lines converted from common 500 kV double-circuit AC lines, the ground total electric field can meet the requirements of corresponding standard with appropriate pole conductor arrangement schemes.展开更多
The micro-defects in epoxy-based insulation materials generate a local high electric field which results in continuous degradation,seriously endangering the insulation system of gas-insulated switchgears.A highly sens...The micro-defects in epoxy-based insulation materials generate a local high electric field which results in continuous degradation,seriously endangering the insulation system of gas-insulated switchgears.A highly sensitive detection technique is reported for micro-defects of insulation pull rods based on the photon counting(PC)technique.The re-sults demonstrated that for an epoxy-based insulation pull rod,the photons released during electroluminescence and ionisation at 2 kV,which is less than the partial discharge inception voltage,can be clearly detected.The findings presented a strong correlation between photon counts and defect severity.Discourse has been conducted to elucidate the mechanism behind defect-induced PC,employing the amplification of ionising luminescence through electric field distortion induced by micro defects and the augmentation of electroluminescence through the aggregation of trap charge.In this regard,the authors verified that PC can serve as a potential tool in the detection of micro-insulation defects,which also has huge potential in online insulation condition monitoring.展开更多
文摘With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the construction investment. In this paper, the upstream finite element method was expanded to calculate the total electric field of same tower multi-circuit DC lines converted from double-circuit AC lines, and the validity of the algorithm was confirmed by experiments. Taking a DC line converted from a typical same tower 500 kV double-circuit AC transmission line as an example, the surface electric field and the ground total electric field in different pole conductor arrangement schemes were calculated and analyzed, and the critical height of pole conductors for DC lines in residential and non-residential area were determined. Then, the corridor width of DC and AC lines at critical height in residential and non-residential areas before and after AC-DC line transformation were compared. The results indicate that for DC lines converted from common 500 kV double-circuit AC lines, the ground total electric field can meet the requirements of corresponding standard with appropriate pole conductor arrangement schemes.
文摘The micro-defects in epoxy-based insulation materials generate a local high electric field which results in continuous degradation,seriously endangering the insulation system of gas-insulated switchgears.A highly sensitive detection technique is reported for micro-defects of insulation pull rods based on the photon counting(PC)technique.The re-sults demonstrated that for an epoxy-based insulation pull rod,the photons released during electroluminescence and ionisation at 2 kV,which is less than the partial discharge inception voltage,can be clearly detected.The findings presented a strong correlation between photon counts and defect severity.Discourse has been conducted to elucidate the mechanism behind defect-induced PC,employing the amplification of ionising luminescence through electric field distortion induced by micro defects and the augmentation of electroluminescence through the aggregation of trap charge.In this regard,the authors verified that PC can serve as a potential tool in the detection of micro-insulation defects,which also has huge potential in online insulation condition monitoring.