期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Effects of vacuum magnetic field region on the compact torus trajectory in a tokamak plasma
1
作者 董期龙 张洁 +28 位作者 兰涛 肖持进 庄革 陈晨 周永康 吴捷 龙婷 聂林 卢鹏程 王天雄 邬佳仁 邓鹏 汪兴康 柏泽琪 黄玉华 李杰 薛雷 阿迪力江 毛文哲 周楚 刘阿娣 吴征威 谢锦林 丁卫星 刘万东 陈伟 钟武律 许敏 段旭如 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期23-39,共17页
The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tok... The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tokamak discharges.This model was used to calculate the trajectory and penetration parameters of CT injections by applying both perpendicular and tangential injection schemes in both HL-2A and ITER tokamaks.For perpendicular injection along the tokamak's major radius direction from the outboard,CTs with the same injection parameters exhibited a 0.08 reduction in relative penetration depth when injected into HL-2A and a 0.13reduction when injected into ITER geometry when considering the vacuum magnetic field region compared with cases where this region was not considered.In addition,we proposed an optimization method for determining the CT's initial injection velocity to accurately calculate the initial injection velocity of CTs for central fueling in tokamaks.Furthermore,this paper discusses schemes for the tangential injection of CT into tokamak discharges.The optimal injection angle and CT magnetic moment direction for injection into both HL-2A and ITER were determined through numerical simulations.Finally,the kinetic energy loss occurring when the CT penetrated the vacuum magnetic field region in ITER was reduced byΔEk=975.08 J by optimizing the injection angle for the CT injected into ITER.These results provide valuable insights for optimizing injection angles in fusion experiments.Our model closely represents actual experimental scenarios and can assist the design of CT parameters. 展开更多
关键词 compact torus central fueling vacuum magnetic field region penetration mechanism optimization parameters
下载PDF
Polarimeter–interferometer diagnostic using terahertz solid-state sources for fluctuation measurements on Keda Torus e Xperiment(KTX)
2
作者 汪兴康 毛文哲 +17 位作者 谢锦林 兰涛 李弘 刘阿娣 周楚 温晓辉 卫子安 吴捷 陈晨 刘东宽 饶贤昊 蔡虎 邬佳仁 邓鹏 刘海庆 丁卫星 庄革 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期61-65,共5页
A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-s... A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities. 展开更多
关键词 plasma diagnostics INTERFEROMETRY TERAHERTZ POLARIMETER
下载PDF
Comparison of transport coefficients before and after density pump-out induced by resonant magnetic perturbation using a BOUT++ six-field model on the EAST tokamak
3
作者 邓成成 刘子奚 +22 位作者 夏天阳 刘彦君 厉鹏程 龙飞飞 高翔 王守信 李国强 刘海庆 臧庆 李玖瑛 杨康宁 吴茗甫 尹晓宇 李弘 谢锦林 兰涛 毛文哲 刘阿娣 周楚 丁卫星 庄革 刘万东 the EAST Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期111-119,共9页
Many experiments have demonstrated that resonant magnetic perturbation(RMP) can affect the turbulent transport at the edge of the tokamak. Through the Experimental Advanced Superconducting Tokamak(EAST) density modula... Many experiments have demonstrated that resonant magnetic perturbation(RMP) can affect the turbulent transport at the edge of the tokamak. Through the Experimental Advanced Superconducting Tokamak(EAST) density modulation experiment, the particle transport coefficients were calculated using the experimental data, and the result shows that the particle transport coefficients increase with RMP. In this study, the six-field two-fluid model in BOUT++ is used to simulate the transport before and after density pump-out induced by RMP,respectively referred as the case without RMP and the case with RMP. In the linear simulations,the instabilities generally decreases for cases with RMP. In the nonlinear simulation, ELM only appears in the case without RMP. Additionally, the particle transport coefficient was analyzed,and the result shows that the particle transport coefficient becomes larger for the case with RMP,which is consistent with the experimental conclusion. Moreover, its magnitude is comparable to the results calculated from experimental data. 展开更多
关键词 BOUT++ resonant magnetic perturbation(RMP) transport coefficients
下载PDF
Comparison of methods for turbulence Doppler frequency shift calculation in Doppler reflectometer
4
作者 仲小明 邹晓岚 +16 位作者 周楚 刘阿娣 庄革 冯喜 张津 季佳旭 范泓锐 刘深 王士凡 高刘天 史文祥 兰涛 李弘 谢锦林 毛文哲 刘子奚 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第9期42-50,共9页
The Doppler reflectometer(DR),a powerful diagnostic for the plasma perpendicular velocity(u⊥)and turbulence measurement,has been widely used in various fusion devices.Many efforts have been put into extracting the Do... The Doppler reflectometer(DR),a powerful diagnostic for the plasma perpendicular velocity(u⊥)and turbulence measurement,has been widely used in various fusion devices.Many efforts have been put into extracting the Doppler shift from the DR signal.There are several commonly used methods for Doppler shift extraction,such as the phase derivative,the center of gravity,and symmetric fitting(SFIT).However,the strong zero-order reflection component around 0 kHz may interfere with the calculation of the Doppler shift.To avoid the influence of the zerofrequency peak,the asymmetric fitting(AFIT)method was designed to calculate the Doppler shift.Nevertheless,the AFIT method may lead to an unacceptable error when the Doppler shift is relatively small compared to the half width at half maximum(HWHM).Therefore,an improved method,which can remove the zero-frequency peak and fit the remaining Doppler peak with a Gaussian function,is devised to extract the Doppler shift.This method can still work reliably whether the HWHM is larger than the Doppler shift or not. 展开更多
关键词 perpendicular velocity measurement Doppler reflectometer Doppler shift
下载PDF
Development of a compact torus injection system for the Keda Torus eXperiment 被引量:3
5
作者 Chen CHEN Tao LAN +19 位作者 Chijin XIAO Ge ZHUANG Defeng KONG Shoubiao ZHANG Sen ZHANG Weixing DING Zhengwei WU wenzhe mao Jie WU Hangqi XU Jiaren WU Yiming ZU Dong ZHANG Zian WEI Xiaohui WEN Chu ZHOU Ahdi LIU Jinlin XIE Hong LI Wandong LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第4期114-123,共10页
A compact torus injection system,KTX-CTI,has been developed for the planned injection experiments on the Keda Torus e Xperiment(KTX)reversed field pinch(RFP)device to investigate the physics and engineering issues ass... A compact torus injection system,KTX-CTI,has been developed for the planned injection experiments on the Keda Torus e Xperiment(KTX)reversed field pinch(RFP)device to investigate the physics and engineering issues associated with interaction between a compact torus(CT)and RFP.The key interests include fueling directly into the reactor center,confinement improvement,and the injection of momentum and helicity into the RFP discharges.The CT velocity and mass have been measured using a multichannel optical fiber interferometer,and for the first time the time evolution of the CT density profile during CT propagation is obtained.The effects of discharge parameters on the number of injected particles,CT velocity and CT density have been characterized:the maximum hydrogen CT plasma mass,m,CTis 50μg,corresponding to 30%of the mass in a typical KTX plasma;the CT velocity exceeds 120 km s-1.It is observed for the first time that multiple CTs can be produced and emitted during a very short period(<100μs)in one discharge,which is significant for the future study of repetitive CT injection,even with an ultra-high frequency. 展开更多
关键词 compact torus injection central fueling reversed field pinch
下载PDF
Investigation of the compact torus plasma motion in the KTX-CTI device based on circuit analyses 被引量:1
6
作者 Qilong DONG Defeng KONG +19 位作者 Xiaohe WU Yang YE Kun YANG Tao LAN Chen CHEN Jie WU Sen ZHANG wenzhe mao Zhihao ZHAO Fanwei MENG Xiaohui ZHANG Yanqing HUANG Wei BAI Dezheng YANG Fei WEN Pengfei ZI Lei LI Guanghai HU Shoubiao ZHANG Ge ZHUANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第2期36-44,共9页
Compact torus(CT)injection is one of the most promising methods for the central fuelling of next-generation reactor-grade fusion devices due to its high density,high velocity,and selfcontained magnetised structure.A n... Compact torus(CT)injection is one of the most promising methods for the central fuelling of next-generation reactor-grade fusion devices due to its high density,high velocity,and selfcontained magnetised structure.A newly compact torus injector(CTI)device in Keda Torus e Xperiment(KTX),named KTX-CTI,was successfully developed and tested at the University of Science and Technology in China.In this study,first,we briefly introduce the basic principles and structure of KTX-CTI,and then,present an accurate circuit model that relies on nonlinear regression analysis(NRA)for studying the current waveform of the formation region.The current waveform,displacement,and velocity of CT plasma in the acceleration region are calculated using this NRA-based one-dimensional point model.The model results were in good agreement with the experiments.The next-step upgrading reference scheme of the KTX-CTI device is preliminarily investigated using this NRA-based point model.This research can provide insights for the development of experiments and future upgrades of the device. 展开更多
关键词 compact torus(CT) circuit modelling nonlinear regression analysis(NRA) point model
下载PDF
Design of the poloidal field system for KTX 被引量:1
7
作者 Wei YOU Hong LI +14 位作者 wenzhe mao Wei BAI Cui TU Bing LUO Zichao LI Yolbarsop ADIL Jintong HU Bingjia XIAO Qingxi YANG Jinlin XIE Tao LAN Adi LIU Weixing DING Chijin XIAO Wandong LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第11期126-134,共9页
The design of the poloidal field (PF) system includes the ohmic heating field system and the equilibrium (EQ) field system, and is the basis for the design of a magnetic confinement fusion device. A coupling betwe... The design of the poloidal field (PF) system includes the ohmic heating field system and the equilibrium (EQ) field system, and is the basis for the design of a magnetic confinement fusion device. A coupling between the poloidal and plasma currents, especially the eddy current in the stabilizing shell, yields design difficulties. The effects of the eddy current in the stabilizing shell on the poloidal magnetic field also cannot be ignored. A new PF system design is thus proposed. By using a low-μ material (μ = 0.001, ε = 1) instead of a conductive shell, an electromagnetic model is established that can provide a continuous eddy current distribution on the conductive shell. In this model, a 3D time-domain problem with shells translates into a 2D magnetostatic problem, and the accuracy of the calculation is improved. Based on these current distributions, we design the PF system and analyze how the EQ coils and conductive shell affect the plasma EQ when the plasma ramps up. To meet the mainframe design requirements and achieve an efficient power-supply design, the position and connection of the poloidal coils are optimized further. 展开更多
关键词 RFP KTX poloidal field system electromagnetic design
下载PDF
Bench test of interferometer measurement for the Keda Reconnection eXperiment device(KRX) 被引量:1
8
作者 Dongkuan LIU Weixing DING +4 位作者 wenzhe mao Qiaofeng ZHANG Longlong SANG Quanming LU Jinlin XIE 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第6期32-37,共6页
Motivated by the need of the electron density measurement for the Keda Reconnection eXperiment(KRX)facility which is under development,an interferometer system has been designed and tested in bench.The 320 GHz solid-s... Motivated by the need of the electron density measurement for the Keda Reconnection eXperiment(KRX)facility which is under development,an interferometer system has been designed and tested in bench.The 320 GHz solid-state microwave source with 1 mm wavelength is used to fulfill the high phase difference measurement in such low temperature plasma device.The results of the bench test show that the phase difference is accurately measured.In contrast to tens of degrees of phase shift expected to be measured on the KRX,the system noise(~1°)is low enough for the KRX diagnostics.In order to optimize the system for better performance,we utilize the Terasense sub-THz imaging system to adjust alignment.The interferometer system has also been calibrated via changing of the optical path length controlled by the piezo inertial motor.Simultaneously,high density polyethylene thin film is introduced successfully to change a tiny phase difference and test the sensitivity of the interferometer system. 展开更多
关键词 magnetic reconnection DIAGNOSTICS INTERFEROMETER
下载PDF
Fast radial scanning probe system on KTX
9
作者 Tijian DENG Tao LAN +22 位作者 Mingsheng TAN Junfeng ZHU Jie WU Hangqi XU Chen CHEN Yolbarsop ADIL Sen ZHANG Jiaren WU Yiming ZU wenzhe mao Hong LI Jinlin Xie Ahdi LIU Zixi LIU Zhengwei WU Hai WANG Xiaohui WEN Haiyang ZHOU Zian WEI Chijin XIAO Weixing DING Ge ZHUANG Wandong LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第4期97-104,共8页
A fast radial scanning probe system was constructed for the Keda Torus eXperiment(KTX)to measure the profiles of boundary plasma parameters such as floating potential,electron density,temperature,transport fluxes,etc.... A fast radial scanning probe system was constructed for the Keda Torus eXperiment(KTX)to measure the profiles of boundary plasma parameters such as floating potential,electron density,temperature,transport fluxes,etc.The scanning probe system is driven by slow and fast motion mechanisms,corresponding to the stand-by movement of a stepping motor and the fast scanning movement of a high-torque servo-motor,respectively.In fast scanning,the scanner drives the probe radially up to 20 cm at a maximum velocity of 4.0 m s-1.A noncontact magnetic grating ruler with a high spatial resolution of 5μm is used for the displacement measurement.New scanning probe can reach the center of plasmas rapidly.The comparison of plasma floating potential profiles obtained by a fixed radial rake probe and the single scanning probe suggests that the high-speed scanning probe system is reliable for measuring edge plasma parameter profiles on the KTX device. 展开更多
关键词 RADIAL SCANNING probe high-speed MOVEMENT NONCONTACT magnetic GRATING RULER
下载PDF
The investigation of quasi coherent mode on EAST using Doppler reflectometry
10
作者 Jiaxu JI Adi LIU +17 位作者 Chu ZHOU Xi FENG Shouxin WANG Haiqing LIU Hailin ZHAO Yong LIU Jin ZHANG Zhaoyang LIU Xiaoming ZHONG Hongrui FAN Ge ZHUANG Jinlin XIE Tao LAN wenzhe mao Weixing DING Hong LI Zixi LIU Wandong LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第9期60-64,共5页
An electrostatic Quasi coherent mode has been observed in density fluctuations and perpendicular velocity fluctuations with the frequency range of 3–80 k Hz on the Experimental Advanced Superconducting Tokamak using ... An electrostatic Quasi coherent mode has been observed in density fluctuations and perpendicular velocity fluctuations with the frequency range of 3–80 k Hz on the Experimental Advanced Superconducting Tokamak using multi-channel Doppler reflectometry.It appears in the edge localized mode(ELM)-free period after L-H transition or in the inter-ELM period.The mode rotates almost together with the plasma with the poloidal wave number around 0.6cm-1 and its frequency chirps with plasma poloidal velocity.The mode can exist in a large radial coverage(ρ=0.75–0.98),and peaks near the top of pedestal,suggesting that it might be excited in the steep gradient pedestal region,and spread into the core area. 展开更多
关键词 H-MODE TURBULENCE quasi coherent mode doppler reflectometry
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部