期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Blood Pressure Estimation with Phonocardiogram on CNN-Based Approach
1
作者 Kasidit Kokkhunthod Khomdet Phapatanaburi +5 位作者 wongsathon pathonsuwan Talit Jumphoo Patikorn Anchuen Porntip Nimkuntod Monthippa Uthansakul Peerapong Uthansakul 《Computers, Materials & Continua》 SCIE EI 2024年第5期1775-1794,共20页
Monitoring blood pressure is a critical aspect of safeguarding an individual’s health,as early detection of abnormal blood pressure levels facilitates timely medical intervention,ultimately leading to a reduction in ... Monitoring blood pressure is a critical aspect of safeguarding an individual’s health,as early detection of abnormal blood pressure levels facilitates timely medical intervention,ultimately leading to a reduction in mortality rates associated with cardiovascular diseases.Consequently,the development of a robust and continuous blood pressure monitoring system holds paramount significance.In the context of this research paper,we introduce an innovative deep learning regression model that harnesses phonocardiogram(PCG)data to achieve precise blood pressure estimation.Our novel approach incorporates a convolutional neural network(CNN)-based regression model,which not only enhances its adaptability to spatial variations but also empowers it to capture intricate patterns within the PCG signals.These advancements contribute significantly to the overall accuracy of blood pressure estimation.To substantiate the effectiveness of our proposed method,we meticulously gathered PCG signal data from 78 volunteers,adhering to the ethical guidelines of Suranaree University of Technology(Human Research Ethics number EC-65-78).Subsequently,we rigorously preprocessed the dataset to ensure its integrity.We further employed a K-fold cross-validation procedure for data division and alignment,combining the resulting datasets with a CNNfor blood pressure estimation.The experimental results are highly promising,yielding aMeanAbsolute Error(MAE)and standard deviation(STD)of approximately 10.69±7.23 mmHg for systolic pressure and 6.89±5.22 mmHg for diastolic pressure.Our study underscores the potential for precise blood pressure estimation,particularly using PCG signals,paving the way for a practical,non-invasive method with broad applicability in the healthcare domain.Early detection of abnormal blood pressure levels can facilitate timely medical interventions,ultimately reducing cardiovascular disease-related mortality rates. 展开更多
关键词 Blood pressure PHONOCARDIOGRAM CNN-based deep learning
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部