In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the...In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the ray emitted from a source located at one focus of an ellipse will converge on the other focus by the reflection of the elliptical surface. The focal length and the eccentricity of the ellipse are 1350 mm and 0.9586, respectively. The spectrometer can be used to measure the X- ray lines in the wavelength range of 0.2-0.37 nm, and a LiF crystal (200) (2d = 0.4027 nm) is used as dispersive element covering Bragg angle from 30° to 67.5°. The spectrometer was tested on Shengnang- Ⅱ which can deliver laser energy of 60-80 J/pulse and the laser wavelength is 0.35 μm. Photographs of spectra including the 1 s2p ^1P1-1s^2 ^1S0 resonance line(w), the 1s2p ^3P2-1s^2 1S0 magnetic quadrupole line(x), the 1s2p ^3P1-1 s^2 ^1S0 intercombination lines(y), the 1 s2p ^3S^1-1 s^2 ^1S0 forbidden line(z) in helium-like Ti Ⅹ Ⅺ and the 1 s2s2p ^2P3/2-1 s622s ^2S1/2 line(q) in lithium-like Ti Ⅹ Ⅹhave been recorded with a X-ray CCD camera. The experimental result shows that the wavelength resolution(λ/△ 2) is above 1000 and the elliptical crystal spectrometer is suitable for X-ray spectroscopy.展开更多
基金the National Natural Science Foundation of China(Grant No. 10576041)
文摘In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the ray emitted from a source located at one focus of an ellipse will converge on the other focus by the reflection of the elliptical surface. The focal length and the eccentricity of the ellipse are 1350 mm and 0.9586, respectively. The spectrometer can be used to measure the X- ray lines in the wavelength range of 0.2-0.37 nm, and a LiF crystal (200) (2d = 0.4027 nm) is used as dispersive element covering Bragg angle from 30° to 67.5°. The spectrometer was tested on Shengnang- Ⅱ which can deliver laser energy of 60-80 J/pulse and the laser wavelength is 0.35 μm. Photographs of spectra including the 1 s2p ^1P1-1s^2 ^1S0 resonance line(w), the 1s2p ^3P2-1s^2 1S0 magnetic quadrupole line(x), the 1s2p ^3P1-1 s^2 ^1S0 intercombination lines(y), the 1 s2p ^3S^1-1 s^2 ^1S0 forbidden line(z) in helium-like Ti Ⅹ Ⅺ and the 1 s2s2p ^2P3/2-1 s622s ^2S1/2 line(q) in lithium-like Ti Ⅹ Ⅹhave been recorded with a X-ray CCD camera. The experimental result shows that the wavelength resolution(λ/△ 2) is above 1000 and the elliptical crystal spectrometer is suitable for X-ray spectroscopy.