A new heat flux coefficient model and improved refreshing rules were introduced for optimizing coiling temperature model. The off-line simulation of the new strategy was performed by laminar cooling intelligent softwa...A new heat flux coefficient model and improved refreshing rules were introduced for optimizing coiling temperature model. The off-line simulation of the new strategy was performed by laminar cooling intelligent software, and the on-line application shows that the control of coiling temperature has been improved significantly.展开更多
A three-dimensional finite element method was developed to simulate the fluid flow,heat transfer and solidification for twin roll strip casting.An improved two-equationκ-εmodel was used to incorporate the turbulence...A three-dimensional finite element method was developed to simulate the fluid flow,heat transfer and solidification for twin roll strip casting.An improved two-equationκ-εmodel was used to incorporate the turbulence in fluid flow.The influence of vertical feeding and submerged entry nozzle feeding on the flow and temperature field was discussed.The optimum submersion depth and entry angle of submerged nozzle were obtained through comparison of the simulation results.展开更多
文摘A new heat flux coefficient model and improved refreshing rules were introduced for optimizing coiling temperature model. The off-line simulation of the new strategy was performed by laminar cooling intelligent software, and the on-line application shows that the control of coiling temperature has been improved significantly.
基金Item Sponsored by National Natural Science Foundation of China(59995440)
文摘A three-dimensional finite element method was developed to simulate the fluid flow,heat transfer and solidification for twin roll strip casting.An improved two-equationκ-εmodel was used to incorporate the turbulence in fluid flow.The influence of vertical feeding and submerged entry nozzle feeding on the flow and temperature field was discussed.The optimum submersion depth and entry angle of submerged nozzle were obtained through comparison of the simulation results.