期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Design and high-power testing of offline conditioning cavity for CiADS RFQ high-power coupler
1
作者 Ruo-xu Wang Yuan He +6 位作者 Long-Bo Shi Chen-Xing Li Zong-Heng xue Tian-Cai Jiang xian-bo xu Lie-Peng Sun Zhou-Li Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期18-27,共10页
To validate the design rationality of the power coupler for the RFQ cavity and minimize cavity contamination,we designed a low-loss offline conditioning cavity and conducted high-power testing.This offline cavity feat... To validate the design rationality of the power coupler for the RFQ cavity and minimize cavity contamination,we designed a low-loss offline conditioning cavity and conducted high-power testing.This offline cavity features two coupling ports and two tuners,operating at a frequency of 162.5 MHz with a tuning range of 3.2 MHz.Adjusting the installation angle of the coupling ring and the insertion depth of the tuner helps minimize cavity losses.We performed electromagnetic structural and multiphysics simulations,revealing a minimal theoretical power loss of 4.3%.However,when the cavity frequency varied by110 kHz,theoretical power losses increased to10%,necessitating constant tuner adjustments during conditioning.Multiphysics simulations indicated that increased cavity temperature did not affect frequency variation.Upon completion of the offline high-power conditioning platform,we measured the transmission performance,revealing a power loss of 6.3%,exceeding the theoretical calculation.Conditioning utilized efficient automatic range scanning and standing wave resonant methods.To fully condition the power coupler,a 15°phase difference between two standing wave points in the condition-ing system was necessary.Notably,the maximum continuous wave power surpassed 20 kW,exceeding the expected target. 展开更多
关键词 RFQ cavity Power coupler Offline conditioning Resonant cavity
下载PDF
New thermal optimization scheme of power module in solid-state amplifier 被引量:3
2
作者 Lie-Peng Sun Zhen-Yu Yuan +5 位作者 Cheng Zhang xian-bo xu Jun-Gang Miao Jian-Hua Zhang Long-Bo Shi Yuan He 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第4期143-149,共7页
The new 1 kW power module for ADS project needs the optimization of cooling design including water flow and tunnel layout, and the water flow of three tons per hour was chosen to be a goal for a 20 kW power source.Acc... The new 1 kW power module for ADS project needs the optimization of cooling design including water flow and tunnel layout, and the water flow of three tons per hour was chosen to be a goal for a 20 kW power source.According to analysis from the insertion and integrated loss, about 24 modules were integrated into the rated power. Thus, every module has a cooling flow of 2.1 L/min for RF heat load and power supply loss, which is very hard to achieve if no special consideration and techniques. A new thermal simulation method was introduced for thermal analysis of cooling plate through CST multi-physics suite,especially for temperature of power LDMOS transistor.Some specific measures carried out for the higher heat transfer were also presented in this paper. 展开更多
关键词 RF system SOLID-STATE AMPLIFIER Power MODULE HEAT TRANSFER COEFFICIENT
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部