Intrauterine adhesion (IUA) is the fibrosis within the uterine cavity. It is the second most common cause of female infertility, significantly affecting women’s physical and mental health. Current treatment strategie...Intrauterine adhesion (IUA) is the fibrosis within the uterine cavity. It is the second most common cause of female infertility, significantly affecting women’s physical and mental health. Current treatment strategies fail to provide a satisfactory therapeutic outcome for IUA patients, leaving an enormous challenge for reproductive science. A self-healing adhesive hydrogel with antioxidant properties will be highly helpful in IUA prevention. In this work, we prepare a series of self-healing hydrogels (P10G15, P10G20, and P10G25) with antioxidant and adhesive properties. Those hydrogels exhibit good self-healing properties and can adapt themselves to different structures. They possess good injectability and fit the shape of the human uterus. Moreover, the hydrogels exhibit good tissue adhesiveness, which is desirable for stable retention and therapeutic efficacy. The in vitro experiments using P10G20 show that the adhesive effectively scavenges ABTS+, DPPH, and hydroxyl radicals, rescuing cells from oxidative stress. In addition, P10G20 offers good hemocompatibility and in vitro and in vivo biocompatibility. Furthermore, P10G20 lowers down the in vivo oxidative stress and prevents IUA with less fibrotic tissue and better endometrial regeneration in the animal model. It can effectively downregulate fibrosis-related transforming growth factor beta 1 (TGF-β1) and vascular endothelial growth factor (VEGF). Altogether, these adhesives may be a good alternative for the clinical treatment of intrauterine adhesion.展开更多
Fluorescent analysis of bone provides valuable insights into bone structures.However,conventional dyes suffer from low specificity on bone tissue,small stokes shift,short fluorescent lifetime,and aggregation-caused qu...Fluorescent analysis of bone provides valuable insights into bone structures.However,conventional dyes suffer from low specificity on bone tissue,small stokes shift,short fluorescent lifetime,and aggregation-caused quenching effect,which result in low efficacy and artifacts.In this work,we design an aggregation-induced emission(AIE)-active iridium(III)complex(Ir-BP2)as a highly selective,convenient,nondestructiveness,and dual-mode staining agent for bone analysis.Ir-BP2 containing phosphonate groups selectively binds to hydroxyapatites,the main component of bone matrix,and exhibits turn-on AIE phosphorescence with prolonged lifetime.Ir-BP2 exhibits promising biosafety and offers higher accuracy in staining calcium deposits than conventional Alizarin Red S staining assay when it is employed in real-time monitoring of osteogenesis differentiation process.A ready-to-use staining spray of Ir-BP2 is fabricated.By using fluorescent imaging and lifetime imaging,Ir-BP2 staining provides valuable insights into bone microstructure analysis,microdamage diagnosis,and bone growth state identification.Further,Ir-BP2 is successfully applied on a human spine vertebra for diagnosing bone invasiveness of eosinophilic granuloma,validating its clinical practice.This work presents a powerful tool in bone analysis and will lead to new approaches for the diagnosis and treatment of bone-related diseases.展开更多
Sensitive and fast detection of neutrons and gamma rays is vital for homeland security,high-energy physics,and proton therapy.Fast-neutron detectors rely on light organic scintillators,andγ-ray detectors use heavy in...Sensitive and fast detection of neutrons and gamma rays is vital for homeland security,high-energy physics,and proton therapy.Fast-neutron detectors rely on light organic scintillators,andγ-ray detectors use heavy inorganic scintillators and semiconductors.Efficient mixed-field detection using a single material is highly challenging due to their contradictory requirements.Here we report hybrid perovskites(C_(8)H_(12)N)_(2)Pb(Br_(0.95)Cl_(0.05))_(4)that combine light organic cations and heavy inorganic skeletons at a molecular level to achieve unprecedented performance for mixed-field radiation detection.High neutron absorption due to a high density of hydrogen,strong radiative recombination within the highly confined[PbX_(6)]^(4-)layer,and sub-nanometer distance between absorption sites and radiative centers,enable a light yield of 41000 photons/MeV,detection pulse width of 2.97 ns and extraordinary linearity response toward both fast neutrons andγ-rays,outperforming commonly used fast-neutron scintillators.Neutron energy spectrum,time-of-flight based fast-neutron/γ-ray discrimination and neutron yield monitoring were all successfully achieved using(C_(8)H_(12)N)_(2)Pb(Br_(0.95)Cl_(0.05))_(4)detectors.We further demonstrate the monitoring of reaction kinetics and total power of a nuclear fusion reaction.We envision that molecular hybridized scintillators open a new avenue for mixed-field radiation detection and imaging.展开更多
The tire spray produced by aircraft running on wet runways may enter the intake of engines,which may lead to the compressor stall,surge,or even combustion flameout.Therefore,it is necessary to do some research work on...The tire spray produced by aircraft running on wet runways may enter the intake of engines,which may lead to the compressor stall,surge,or even combustion flameout.Therefore,it is necessary to do some research work on the tire spray to help to solve this problem.Firstly,the mechanism of tire spray is analyzed,and some parameters are defined to describe the spray pattern.Secondly,the numerical model of tire spray is established by coupled Smoothed Particle Hydrodynamics(SPH)and Finite Element Method(FEM)in LS-DYNA software,and the model is validated by a simplified water spray experiment.Then some influence factors on the spray pattern are studied by numerical simulation.Finally,some suggestions are proposed on different types of aircraft to avoid too much tire spray being ingested into the engine intakes.展开更多
The capture cross sections of the ^(169)Tm(n,γ)reaction were measured at the back streaming white neutron beam line(Back-n)of the China Spallation Neutron Source(CSNS)using four C_(6)D_(6) liquid scintillation detect...The capture cross sections of the ^(169)Tm(n,γ)reaction were measured at the back streaming white neutron beam line(Back-n)of the China Spallation Neutron Source(CSNS)using four C_(6)D_(6) liquid scintillation detectors.The background subtraction,normalization,and correction were carefully considered in the data analysis to obtain accurate cross sections.For the resonance at 3.9 eV,the R-matrix code SAMMY was used to determine the resonance parameters with the internal normalization method.The average capture cross sections of ^(169)Tm for energy between 30 and 300 keV were extracted relative to the ^(197)Au(n,γ)reaction.The measured cross sections of the ^(169)Tm(n,γ)reaction were reported in logarithmically equidistant energy bins with 20 bins per energy decade with a total uncertainty of 5.4%-7.0% in this study and described in terms of average resonance parameters using a Hauser-Feshbach calculation with fluctuations.The point-wise cross sections and the average resonance parameters showed fair agreement with the evaluated values of the ENDF/B-Ⅷ.0 library in the energy region studied.展开更多
The^6 Li(n,t)~4 He reaction was measured as the first experiment involving neutron-induced charged particle emission reactions at the CSNS(China Spallation Neutron Source)Back-n white neutron source.The differential c...The^6 Li(n,t)~4 He reaction was measured as the first experiment involving neutron-induced charged particle emission reactions at the CSNS(China Spallation Neutron Source)Back-n white neutron source.The differential cross-sections of the^6 Li(n,t)~4 He reaction at 15 detection angles ranging from 19.2°to 160.8°are obtained from 1.0 eV to 3.0 MeV at 80 neutron energy points;for 50 energy points below 0.1 MeV they are reported for the first time.The results indicate that the anisotropy of the emitted tritium is noticeable above E_n=100 eV.The angle-integrated cross-sections are also obtained.The present differential cross-sections agree in general with the previous evaluations,but there are some differences in the details.More importantly,the present results indicate that the cross-sections of the^6 Li(n,t)~4 He reaction might be overestimated by most evaluations in the 0.5-3.0 MeV region,although they are recommended as standards below 1.0 MeV.展开更多
Introduction The neutron capture cross sections are very important in the field of nuclear device design and basic physics research.Hydrogen-free liquid scintillator such as C_(6)D_(6)detectors are widely used in the ...Introduction The neutron capture cross sections are very important in the field of nuclear device design and basic physics research.Hydrogen-free liquid scintillator such as C_(6)D_(6)detectors are widely used in the neutron capture cross-sectional measurements for the low neutron sensitivity and fast time response.The Back-n white neutron source at China Spallation Neutron Source is the first spallation white neutron source in China,and it is suitable for neutron capture cross-sectional measurement.Materials and methods A C_(6)D_(6)detector system was built in the Back-n experimental station.The pulse height weighting technique was used to determine the system’s detection efficiency.The response to gamma rays of the C_(6)D_(6)detector was measured,and the energy resolution function was determined.Monte Carlo simulation with Geant4 code was carried out to get the weighting function of this C_(6)D_(6)detector system.Additionally,the systematic uncertainty of the weighting function was also determined.Conclusion According to the experimental and simulation results,this C_(6)D_(6)detector system can be used to measure neutron capture cross section.展开更多
Differential and angle-integrated cross sections for the 10B(n,α)^7 Li,10B(n,α0)^7 Li and 10B(n,α1)^7 Li^*reactions have been measured at CSNS Back-n white neutron source.Two enriched(90%)10B samples 5.0 cm in diam...Differential and angle-integrated cross sections for the 10B(n,α)^7 Li,10B(n,α0)^7 Li and 10B(n,α1)^7 Li^*reactions have been measured at CSNS Back-n white neutron source.Two enriched(90%)10B samples 5.0 cm in diameter and^85.0μg/cm^2 in thickness each with an aluminum backing were prepared,and back-to-back mounted at the sample holder.The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array(LPDA)system.The neutron energy En was determined by TOF(time-of-flight)method,and the valid a events were extracted from the En-Amplitude two-dimensional spectrum.With 15 silicon detectors,the differential cross sections of a-particles were measured from 19.2°to 160.8°.Fitted with the Legendre polynomial series,the(n,a)cross sections were obtained through integration.The absolute cross sections were normalized using the standard cross sections of the 10B(n,α)^7 Li reaction in the 0.3-0.5 MeV neutron energy region.The measurement neutron energy range for the 10B(n,α)^7 Li reaction is 1.0 eV≤En<2.5 Me V(67 energy points),and that for the 10B(n,α0)^7 Li and10B(n,α1)^7 Li^*reactions is 1.0 eV≤En<1.0 MeV(59 energy points).The present results have been analyzed by the resonance reaction mechanism and the level structure of the 11B compound system,and compared with existing measurements and evaluations.展开更多
The Back-n white neutron source(known as Back-n)is based on back-streaming neutrons from the spallation target at the China Spallation Neutron Source(CSNS).With its excellent beam properties,e.g.,a neutron flux of app...The Back-n white neutron source(known as Back-n)is based on back-streaming neutrons from the spallation target at the China Spallation Neutron Source(CSNS).With its excellent beam properties,e.g.,a neutron flux of approximately 1.8×107 n/cm2/s at 55 m from the spallation target,energy range spanning from 0.5 eV to 200 MeV,and time-of-flight resolution of a few per thousand,along with the equipped physical spectrometers,Back-n is considered to be among the best facilities in the world for carrying out nuclear data measurements.Since its completion and commencement of operation in May 2018,five types of cross-section measurements concerning neutron capture cross-sections,fission cross-sections,total cross-sections,light charged particle emissions,in-beam gamma spectra,and more than forty nuclides have been measured.This article presents an overview of the experimental setup and result analysis on the neutron-induced cross-section measurements and gamma spectroscopy at Back-n in the initial years.展开更多
The angle-differential cross sections of neutron-induced deuteron production from carbon were measured at six neutron energies from 25 to 52 MeV relative to those of n-p elastic scattering at the China Spallation Neut...The angle-differential cross sections of neutron-induced deuteron production from carbon were measured at six neutron energies from 25 to 52 MeV relative to those of n-p elastic scattering at the China Spallation Neutron Source(CSNS)Back-n white neutron source.By employing theΔE-E telescopes of the Light-charged Particle Detector Array(LPDA)system at 15.1°to 55.0°in the laboratory system,ratios of the angle-differential cross sections of the ^(12)C(n,xd)reactions to those of the n-p scattering were measured,and then,the angle-differential cross sections of the ^(12)C(n,xd)reactions were obtained using the angle-differential cross sections of the n-p elastic scattering from the JENDL-4.0/HE-2015 library as the standard.The obtained results are compared with data from previous measurements,all of which are based on mono-energic neutrons,the evaluated data from the JENDL-4.0/HE-2015 library and the ENDF-B/VIII.0 library,and those from theoretical calculations based on INCA code and Talys-1.9 code.Being the first white-neutron-source-based systematic measurement of the angle-differential cross sections of neutron-induced deuteron production reactions on carbon in several tens of MeV,the present work can provide a reference to the data library considering the lack of experimental data.展开更多
基金supported by the National Natural Science Foundation of China(52103184,81660265,81960276)Natural Science Foundation of Jiangxi Province(20224BAB206026)+1 种基金Key Research and Development Program of Jiangxi Province(20202BBGL73065)Funding for Basic Scientific Research and‘Young Talent Support Plan’of Xi’an Jiaotong University(xzy012022038).
文摘Intrauterine adhesion (IUA) is the fibrosis within the uterine cavity. It is the second most common cause of female infertility, significantly affecting women’s physical and mental health. Current treatment strategies fail to provide a satisfactory therapeutic outcome for IUA patients, leaving an enormous challenge for reproductive science. A self-healing adhesive hydrogel with antioxidant properties will be highly helpful in IUA prevention. In this work, we prepare a series of self-healing hydrogels (P10G15, P10G20, and P10G25) with antioxidant and adhesive properties. Those hydrogels exhibit good self-healing properties and can adapt themselves to different structures. They possess good injectability and fit the shape of the human uterus. Moreover, the hydrogels exhibit good tissue adhesiveness, which is desirable for stable retention and therapeutic efficacy. The in vitro experiments using P10G20 show that the adhesive effectively scavenges ABTS+, DPPH, and hydroxyl radicals, rescuing cells from oxidative stress. In addition, P10G20 offers good hemocompatibility and in vitro and in vivo biocompatibility. Furthermore, P10G20 lowers down the in vivo oxidative stress and prevents IUA with less fibrotic tissue and better endometrial regeneration in the animal model. It can effectively downregulate fibrosis-related transforming growth factor beta 1 (TGF-β1) and vascular endothelial growth factor (VEGF). Altogether, these adhesives may be a good alternative for the clinical treatment of intrauterine adhesion.
基金National Natural Science Foundation of China,Grant/Award Number:22107087Yong Talent Support Plan of Xi’an Jiaotong University,Grant/Award Number:YX6J024+1 种基金Science and Technology Planning Project of Guangzhou,Grant/Award Number:202002030089Key Projects of Social Welfare and Basic Research of Zhongshan City,Grant/Award Number:2021B2007。
文摘Fluorescent analysis of bone provides valuable insights into bone structures.However,conventional dyes suffer from low specificity on bone tissue,small stokes shift,short fluorescent lifetime,and aggregation-caused quenching effect,which result in low efficacy and artifacts.In this work,we design an aggregation-induced emission(AIE)-active iridium(III)complex(Ir-BP2)as a highly selective,convenient,nondestructiveness,and dual-mode staining agent for bone analysis.Ir-BP2 containing phosphonate groups selectively binds to hydroxyapatites,the main component of bone matrix,and exhibits turn-on AIE phosphorescence with prolonged lifetime.Ir-BP2 exhibits promising biosafety and offers higher accuracy in staining calcium deposits than conventional Alizarin Red S staining assay when it is employed in real-time monitoring of osteogenesis differentiation process.A ready-to-use staining spray of Ir-BP2 is fabricated.By using fluorescent imaging and lifetime imaging,Ir-BP2 staining provides valuable insights into bone microstructure analysis,microdamage diagnosis,and bone growth state identification.Further,Ir-BP2 is successfully applied on a human spine vertebra for diagnosing bone invasiveness of eosinophilic granuloma,validating its clinical practice.This work presents a powerful tool in bone analysis and will lead to new approaches for the diagnosis and treatment of bone-related diseases.
基金China Postdoctoral Science Foundation,Grant/Award Number:2021T140234Fund for the Natural Science Foundation of Hubei Province,Grant/Award Numbers:2020CFA034,2021CFA036+3 种基金HCP Program for HUSTInnovation Fund of WNLOMajor State Basic Research Development Program of China,Grant/Award Numbers:2018YFA0703200,2021YFB3201000National Natural。
文摘Sensitive and fast detection of neutrons and gamma rays is vital for homeland security,high-energy physics,and proton therapy.Fast-neutron detectors rely on light organic scintillators,andγ-ray detectors use heavy inorganic scintillators and semiconductors.Efficient mixed-field detection using a single material is highly challenging due to their contradictory requirements.Here we report hybrid perovskites(C_(8)H_(12)N)_(2)Pb(Br_(0.95)Cl_(0.05))_(4)that combine light organic cations and heavy inorganic skeletons at a molecular level to achieve unprecedented performance for mixed-field radiation detection.High neutron absorption due to a high density of hydrogen,strong radiative recombination within the highly confined[PbX_(6)]^(4-)layer,and sub-nanometer distance between absorption sites and radiative centers,enable a light yield of 41000 photons/MeV,detection pulse width of 2.97 ns and extraordinary linearity response toward both fast neutrons andγ-rays,outperforming commonly used fast-neutron scintillators.Neutron energy spectrum,time-of-flight based fast-neutron/γ-ray discrimination and neutron yield monitoring were all successfully achieved using(C_(8)H_(12)N)_(2)Pb(Br_(0.95)Cl_(0.05))_(4)detectors.We further demonstrate the monitoring of reaction kinetics and total power of a nuclear fusion reaction.We envision that molecular hybridized scintillators open a new avenue for mixed-field radiation detection and imaging.
基金supported by the Aeronautical Science Foundation of China(No.2016ZD53038)the support of the Commercial Aircraft Corporation of China Ltd.
文摘The tire spray produced by aircraft running on wet runways may enter the intake of engines,which may lead to the compressor stall,surge,or even combustion flameout.Therefore,it is necessary to do some research work on the tire spray to help to solve this problem.Firstly,the mechanism of tire spray is analyzed,and some parameters are defined to describe the spray pattern.Secondly,the numerical model of tire spray is established by coupled Smoothed Particle Hydrodynamics(SPH)and Finite Element Method(FEM)in LS-DYNA software,and the model is validated by a simplified water spray experiment.Then some influence factors on the spray pattern are studied by numerical simulation.Finally,some suggestions are proposed on different types of aircraft to avoid too much tire spray being ingested into the engine intakes.
基金Supported by the National Natural Science Foundation of China(11790321,11805282)the National Key Research and Development Program of China(2016YFA0401601)。
文摘The capture cross sections of the ^(169)Tm(n,γ)reaction were measured at the back streaming white neutron beam line(Back-n)of the China Spallation Neutron Source(CSNS)using four C_(6)D_(6) liquid scintillation detectors.The background subtraction,normalization,and correction were carefully considered in the data analysis to obtain accurate cross sections.For the resonance at 3.9 eV,the R-matrix code SAMMY was used to determine the resonance parameters with the internal normalization method.The average capture cross sections of ^(169)Tm for energy between 30 and 300 keV were extracted relative to the ^(197)Au(n,γ)reaction.The measured cross sections of the ^(169)Tm(n,γ)reaction were reported in logarithmically equidistant energy bins with 20 bins per energy decade with a total uncertainty of 5.4%-7.0% in this study and described in terms of average resonance parameters using a Hauser-Feshbach calculation with fluctuations.The point-wise cross sections and the average resonance parameters showed fair agreement with the evaluated values of the ENDF/B-Ⅷ.0 library in the energy region studied.
基金Supported by National Key R&D Program of China(2016YFA0401604)National Natural Science Foundation of China(11775006)Science and Technology on Nuclear Data Laboratory and China Nuclear Data Center
文摘The^6 Li(n,t)~4 He reaction was measured as the first experiment involving neutron-induced charged particle emission reactions at the CSNS(China Spallation Neutron Source)Back-n white neutron source.The differential cross-sections of the^6 Li(n,t)~4 He reaction at 15 detection angles ranging from 19.2°to 160.8°are obtained from 1.0 eV to 3.0 MeV at 80 neutron energy points;for 50 energy points below 0.1 MeV they are reported for the first time.The results indicate that the anisotropy of the emitted tritium is noticeable above E_n=100 eV.The angle-integrated cross-sections are also obtained.The present differential cross-sections agree in general with the previous evaluations,but there are some differences in the details.More importantly,the present results indicate that the cross-sections of the^6 Li(n,t)~4 He reaction might be overestimated by most evaluations in the 0.5-3.0 MeV region,although they are recommended as standards below 1.0 MeV.
基金the National Natural Science Foundation of China(Grant Nos.11790321 and 11805282)the National Key R&D Program of China(Grant No.2016YFA0401601).
文摘Introduction The neutron capture cross sections are very important in the field of nuclear device design and basic physics research.Hydrogen-free liquid scintillator such as C_(6)D_(6)detectors are widely used in the neutron capture cross-sectional measurements for the low neutron sensitivity and fast time response.The Back-n white neutron source at China Spallation Neutron Source is the first spallation white neutron source in China,and it is suitable for neutron capture cross-sectional measurement.Materials and methods A C_(6)D_(6)detector system was built in the Back-n experimental station.The pulse height weighting technique was used to determine the system’s detection efficiency.The response to gamma rays of the C_(6)D_(6)detector was measured,and the energy resolution function was determined.Monte Carlo simulation with Geant4 code was carried out to get the weighting function of this C_(6)D_(6)detector system.Additionally,the systematic uncertainty of the weighting function was also determined.Conclusion According to the experimental and simulation results,this C_(6)D_(6)detector system can be used to measure neutron capture cross section.
基金Supported by financially the National Key R&D Program of China(2016YFA0401604)the National Natural Science Foundation of China(11775006)
文摘Differential and angle-integrated cross sections for the 10B(n,α)^7 Li,10B(n,α0)^7 Li and 10B(n,α1)^7 Li^*reactions have been measured at CSNS Back-n white neutron source.Two enriched(90%)10B samples 5.0 cm in diameter and^85.0μg/cm^2 in thickness each with an aluminum backing were prepared,and back-to-back mounted at the sample holder.The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array(LPDA)system.The neutron energy En was determined by TOF(time-of-flight)method,and the valid a events were extracted from the En-Amplitude two-dimensional spectrum.With 15 silicon detectors,the differential cross sections of a-particles were measured from 19.2°to 160.8°.Fitted with the Legendre polynomial series,the(n,a)cross sections were obtained through integration.The absolute cross sections were normalized using the standard cross sections of the 10B(n,α)^7 Li reaction in the 0.3-0.5 MeV neutron energy region.The measurement neutron energy range for the 10B(n,α)^7 Li reaction is 1.0 eV≤En<2.5 Me V(67 energy points),and that for the 10B(n,α0)^7 Li and10B(n,α1)^7 Li^*reactions is 1.0 eV≤En<1.0 MeV(59 energy points).The present results have been analyzed by the resonance reaction mechanism and the level structure of the 11B compound system,and compared with existing measurements and evaluations.
基金Supported by the National Key Research and Development Plan(2016YFA0401600)the National Natural Science Foundation of China(11675155,11790321)。
文摘The Back-n white neutron source(known as Back-n)is based on back-streaming neutrons from the spallation target at the China Spallation Neutron Source(CSNS).With its excellent beam properties,e.g.,a neutron flux of approximately 1.8×107 n/cm2/s at 55 m from the spallation target,energy range spanning from 0.5 eV to 200 MeV,and time-of-flight resolution of a few per thousand,along with the equipped physical spectrometers,Back-n is considered to be among the best facilities in the world for carrying out nuclear data measurements.Since its completion and commencement of operation in May 2018,five types of cross-section measurements concerning neutron capture cross-sections,fission cross-sections,total cross-sections,light charged particle emissions,in-beam gamma spectra,and more than forty nuclides have been measured.This article presents an overview of the experimental setup and result analysis on the neutron-induced cross-section measurements and gamma spectroscopy at Back-n in the initial years.
基金Supported by the National Natural Science Foundation of China(11775006)the National Key R&D Program of China(2016YFA0401604)。
文摘The angle-differential cross sections of neutron-induced deuteron production from carbon were measured at six neutron energies from 25 to 52 MeV relative to those of n-p elastic scattering at the China Spallation Neutron Source(CSNS)Back-n white neutron source.By employing theΔE-E telescopes of the Light-charged Particle Detector Array(LPDA)system at 15.1°to 55.0°in the laboratory system,ratios of the angle-differential cross sections of the ^(12)C(n,xd)reactions to those of the n-p scattering were measured,and then,the angle-differential cross sections of the ^(12)C(n,xd)reactions were obtained using the angle-differential cross sections of the n-p elastic scattering from the JENDL-4.0/HE-2015 library as the standard.The obtained results are compared with data from previous measurements,all of which are based on mono-energic neutrons,the evaluated data from the JENDL-4.0/HE-2015 library and the ENDF-B/VIII.0 library,and those from theoretical calculations based on INCA code and Talys-1.9 code.Being the first white-neutron-source-based systematic measurement of the angle-differential cross sections of neutron-induced deuteron production reactions on carbon in several tens of MeV,the present work can provide a reference to the data library considering the lack of experimental data.