AIM:To evaluate the accuracy of segmented measurement of axial length(AL)in high myopia filled with silicone oil by immersion B-scan ultrasonography(immersion B-scan).METHODS:From June 2016 to June 2020,a total of 67 ...AIM:To evaluate the accuracy of segmented measurement of axial length(AL)in high myopia filled with silicone oil by immersion B-scan ultrasonography(immersion B-scan).METHODS:From June 2016 to June 2020,a total of 67 ultra-high myopia inpatients(67 eyes)who underwent silicone oil removal combined with cataract extraction and intraocular lens(IOL)implantation were retrospectively enrolled.The preoperative axial length(AL)of 31 patients with severe cataract were segmented measured using immersion B-scan(B-scan group)and another 36 patients with mild or moderate cataract were measured using IOLMaster 500(IOLMaster group).The post-operative ALs in two groups were both measured using IOLMaster 500.The IOL power was calculated with Haigis formula.The differences in ALs between pre-and post-surgery,as well as the postoperative refractive spherical equivalent,absolute refractive error,the prediction deviation of postoperative refraction and best corrected visual acuity(BCVA)were compared.RESULTS:The pre-and post-operative ALs were 30.46±1.63 mm(range 28.09-33.51 mm)and 30.42±1.70 mm(range 28.03-33.90 mm)in B-scan group(t=0.644,P=0.542)and 30.51±1.21 mm(range 28.03-33.90 mm)and 30.43±1.27 mm(range 28.54-33.50 mm)in IOLMaster group(t=1.843,P=0.074),respectively.Three months after surgery,BCVA were 0.45±0.13(range 0.3-0.9)and 0.44±0.20(range 0.2-1.0)in B-scan and IOLMaster group respectively(t=0.086,P=0.932).There was no significant difference of the postoperative spherical equivalent(-3.11±0.65 D vs-3.21±0.51 D,t=0.671,P=0.505)and the absolute refractive error(0.589±0.340 vs 0.470±0.245 D,t=1.615,P=0.112)between two groups.In B-scan group,absolute refractive error within±0.50 D was found in 18 eyes(58.1%),within±1.00 D in 26 eyes(83.9%),and within±1.50 D in 31 eyes(100%).In IOLMaster group,absolute refractive error within±0.50 D was found in 23 eyes(63.9%),within±1.00 D in 34 eyes(94.4%),and within±1.50 D in 36 eyes(Z=0.757,P=0.449).CONCLUSION:The segmented measurement of ALs by immersion B-scan shows comparable measurement accuracy with that of IOLMaster 500 in ultra-high myopia patients with severe cataract secondary to silicone oil filling and can obtain an ideal postoperative refractive state.展开更多
The electrochemical behavior and passivation properties of 2507 super duplex stainless steel(SDSS)in the hot concentrated seawater with different concentrations at different temperatures are characterized by electroch...The electrochemical behavior and passivation properties of 2507 super duplex stainless steel(SDSS)in the hot concentrated seawater with different concentrations at different temperatures are characterized by electrochemical methods and X-ray photoelectron spectroscopy.The passive film formed on 2507 SDSS belongs to n-type semiconductor and mainly composed of hydroxides and oxides of Fe and Cr under all circumstances.The protectiveness of the passive film decreases with the increase in temperature mainly because of the increase in defect density in the passive film.The corrosion resistance of 2507 decreases with the increase in seawater concentration,and the critical pitting temperature also decreases.展开更多
基金National Natural Science Foundation of China(No.82070921)。
文摘AIM:To evaluate the accuracy of segmented measurement of axial length(AL)in high myopia filled with silicone oil by immersion B-scan ultrasonography(immersion B-scan).METHODS:From June 2016 to June 2020,a total of 67 ultra-high myopia inpatients(67 eyes)who underwent silicone oil removal combined with cataract extraction and intraocular lens(IOL)implantation were retrospectively enrolled.The preoperative axial length(AL)of 31 patients with severe cataract were segmented measured using immersion B-scan(B-scan group)and another 36 patients with mild or moderate cataract were measured using IOLMaster 500(IOLMaster group).The post-operative ALs in two groups were both measured using IOLMaster 500.The IOL power was calculated with Haigis formula.The differences in ALs between pre-and post-surgery,as well as the postoperative refractive spherical equivalent,absolute refractive error,the prediction deviation of postoperative refraction and best corrected visual acuity(BCVA)were compared.RESULTS:The pre-and post-operative ALs were 30.46±1.63 mm(range 28.09-33.51 mm)and 30.42±1.70 mm(range 28.03-33.90 mm)in B-scan group(t=0.644,P=0.542)and 30.51±1.21 mm(range 28.03-33.90 mm)and 30.43±1.27 mm(range 28.54-33.50 mm)in IOLMaster group(t=1.843,P=0.074),respectively.Three months after surgery,BCVA were 0.45±0.13(range 0.3-0.9)and 0.44±0.20(range 0.2-1.0)in B-scan and IOLMaster group respectively(t=0.086,P=0.932).There was no significant difference of the postoperative spherical equivalent(-3.11±0.65 D vs-3.21±0.51 D,t=0.671,P=0.505)and the absolute refractive error(0.589±0.340 vs 0.470±0.245 D,t=1.615,P=0.112)between two groups.In B-scan group,absolute refractive error within±0.50 D was found in 18 eyes(58.1%),within±1.00 D in 26 eyes(83.9%),and within±1.50 D in 31 eyes(100%).In IOLMaster group,absolute refractive error within±0.50 D was found in 23 eyes(63.9%),within±1.00 D in 34 eyes(94.4%),and within±1.50 D in 36 eyes(Z=0.757,P=0.449).CONCLUSION:The segmented measurement of ALs by immersion B-scan shows comparable measurement accuracy with that of IOLMaster 500 in ultra-high myopia patients with severe cataract secondary to silicone oil filling and can obtain an ideal postoperative refractive state.
基金financially supported by the National Natural Science Foundation of China(No.51701102)the Science and Technology Support Plan for Youth Innovation of Colleges in Shandong Province(No.DC2000000891)the Shandong Provincial Key R&D Plan(Nos.2019GHY112050 and 2019GGX104072)。
文摘The electrochemical behavior and passivation properties of 2507 super duplex stainless steel(SDSS)in the hot concentrated seawater with different concentrations at different temperatures are characterized by electrochemical methods and X-ray photoelectron spectroscopy.The passive film formed on 2507 SDSS belongs to n-type semiconductor and mainly composed of hydroxides and oxides of Fe and Cr under all circumstances.The protectiveness of the passive film decreases with the increase in temperature mainly because of the increase in defect density in the passive film.The corrosion resistance of 2507 decreases with the increase in seawater concentration,and the critical pitting temperature also decreases.