Magnesium hydride(MgH_(2)) is a candidate material for hydrogen storage.MgH_(2)-AlH_(3) composite shows superior hydrogen desorption properties than pure MgH_(2).However,this composite still suffers from poor cycling ...Magnesium hydride(MgH_(2)) is a candidate material for hydrogen storage.MgH_(2)-AlH_(3) composite shows superior hydrogen desorption properties than pure MgH_(2).However,this composite still suffers from poor cycling performance.In this work,NbF_(5) was utilized to improve the cycling properties of the MgH_(2)-AlH_(3) composite.Cycling hydrogen desorption studies show that NbF_(5) significantly improves the cycling stability of MgH_(2)-AlH_(3).The MgH_(2)-AlH_(3)-NbF_(5) composite can release about 2.7 wt% of hydrogen at 300℃ for 1 h and the hydrogen desorption capacity can maintain at 2.7 wt% for more than100 cycles.In comparison,the hydrogen desorption capacity of the MgH_(2)-AlH_(3) composite is decreasing with the cycle number increasing.The capacity is reduced from a maximum value of 3.3 wt% to about 1.0 wt% after 40 cycles.Brunauer-Emmett-Teller(BET) surface area measurements show that the particle size of MgH_(2)-AlH_(3) composite decreases after cycling,which means pulverization of the composite.NbF_(5) can to some extent suppress the pulverization of the composite during cycling,which partially contributes to the improvement of the cycling hydrogen desorption properties of the material.展开更多
The importance of properly treating boundary conditions (BCs) in numerical simulation of hemodynamics in intracranial aneurysm (IA) has been increasingly recognized. In this study, we constructed three types of comput...The importance of properly treating boundary conditions (BCs) in numerical simulation of hemodynamics in intracranial aneurysm (IA) has been increasingly recognized. In this study, we constructed three types of computational model for each IA to investigate how the outcome of numerical simulation is affected by the treatment of BCs. The first type of model (i.e., Type-A model) was obtained by applying 3-D hemodynamic modeling to the entire cerebral arterial network, with its solution being taken as the reference for evaluating the performance of the other two types of model (i.e., Type-B and Type-C models) in which 3-D modeling was confined to the aneurysm region. In addition, patient-specific 1-D models of the cerebral arterial network were developed to provide hemodynamic information for setting the inflow/outflow BCs of the 3-D models. Numerical tests on three IAs revealed that prescribing the outflow BCs of a localized 3-D aneurysm model based on 1-D model-simulated outflow division (i.e., Type-B model) instead of imposing the free outflow BC on all outlets (i.e., Type-C model) helped to improve the fidelity of the simulation of intra-aneurysmal hemodynamics, but could not guarantee a complete reproduction of the reference solution obtained by the Type-A model. Moreover, it was found that the outcome of hemodynamic simulation was more sensitive to the treatment of BCs when an aneurysm was located at arterial bifurcation rather than sidewall. These findings highlight the importance of taking into account systemic cerebroarterial hemodynamics in computational modeling of hemodynamics in IAs, especially those located at bifurcations.展开更多
基金financially supported by the National Natural Science Foundation of China(Nos.51771171 and 51971199)the Natural Science Foundation of Guangxi Province(Nos.2019GXNSFBA185004 and 2018GXNSFAA281308)the Basic Ability Improvement Project for Young and Middle-Aged Teachers in Colleges and Universities in Guangxi(No.2019KY0021)。
文摘Magnesium hydride(MgH_(2)) is a candidate material for hydrogen storage.MgH_(2)-AlH_(3) composite shows superior hydrogen desorption properties than pure MgH_(2).However,this composite still suffers from poor cycling performance.In this work,NbF_(5) was utilized to improve the cycling properties of the MgH_(2)-AlH_(3) composite.Cycling hydrogen desorption studies show that NbF_(5) significantly improves the cycling stability of MgH_(2)-AlH_(3).The MgH_(2)-AlH_(3)-NbF_(5) composite can release about 2.7 wt% of hydrogen at 300℃ for 1 h and the hydrogen desorption capacity can maintain at 2.7 wt% for more than100 cycles.In comparison,the hydrogen desorption capacity of the MgH_(2)-AlH_(3) composite is decreasing with the cycle number increasing.The capacity is reduced from a maximum value of 3.3 wt% to about 1.0 wt% after 40 cycles.Brunauer-Emmett-Teller(BET) surface area measurements show that the particle size of MgH_(2)-AlH_(3) composite decreases after cycling,which means pulverization of the composite.NbF_(5) can to some extent suppress the pulverization of the composite during cycling,which partially contributes to the improvement of the cycling hydrogen desorption properties of the material.
基金This work was supported by the Clinical Research Plan of SHDC(Grant Nos.16CR3031A,16CR2045B)the SJTU Medical-Engineering Cross-cutting Research Foundation(Jrant Nos.YG2015MS53,YG2017MS45).
文摘The importance of properly treating boundary conditions (BCs) in numerical simulation of hemodynamics in intracranial aneurysm (IA) has been increasingly recognized. In this study, we constructed three types of computational model for each IA to investigate how the outcome of numerical simulation is affected by the treatment of BCs. The first type of model (i.e., Type-A model) was obtained by applying 3-D hemodynamic modeling to the entire cerebral arterial network, with its solution being taken as the reference for evaluating the performance of the other two types of model (i.e., Type-B and Type-C models) in which 3-D modeling was confined to the aneurysm region. In addition, patient-specific 1-D models of the cerebral arterial network were developed to provide hemodynamic information for setting the inflow/outflow BCs of the 3-D models. Numerical tests on three IAs revealed that prescribing the outflow BCs of a localized 3-D aneurysm model based on 1-D model-simulated outflow division (i.e., Type-B model) instead of imposing the free outflow BC on all outlets (i.e., Type-C model) helped to improve the fidelity of the simulation of intra-aneurysmal hemodynamics, but could not guarantee a complete reproduction of the reference solution obtained by the Type-A model. Moreover, it was found that the outcome of hemodynamic simulation was more sensitive to the treatment of BCs when an aneurysm was located at arterial bifurcation rather than sidewall. These findings highlight the importance of taking into account systemic cerebroarterial hemodynamics in computational modeling of hemodynamics in IAs, especially those located at bifurcations.