期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
First stirling-type cryocooler reaching lambda point of ~4He(2.17K) and its prospect in Chinese HUBS satellite project 被引量:3
1
作者 Jue Wang Changzhao Pan +9 位作者 Tong Zhang Kaiqi Luo xiaotong xi xianlin Wu Jianpeng Zheng Liubiao Chen Junjie Wang Yuan Zhou Hai Jin Wei Cui 《Science Bulletin》 SCIE EI CAS CSCD 2019年第4期219-221,共3页
The issue of "missing baryons” is always an unsolved mystery in galaxy cosmology, and an important reason for the great uncertainty of the galaxies' formation and evolution. To find the "missing" b... The issue of "missing baryons” is always an unsolved mystery in galaxy cosmology, and an important reason for the great uncertainty of the galaxies' formation and evolution. To find the "missing" baryons, extra high-resolution spectral observation and imaging of the soft X-ray band (<1 kev) is required. However, the existing observation methods cannot meet this requirement. Therefore, Tsinghua University leads and proposes the Chinese "Hot Universe Baryon Surveyor (HUBS)" satellite program. 展开更多
关键词 MISSING BARYONS HUBS MISSING
原文传递
Performance improvement of a pulse tube cryocooler with a single compressor through cascade utilization of cold energy
2
作者 Xuming LIU xiafan XU +4 位作者 Biao YANG xiaotong xi Liubiao CHEN Junjie WANG Yuan ZHOU 《Frontiers in Energy》 SCIE CSCD 2021年第2期345-357,共13页
The high-frequency pulse tube cryocooler(HPTC)has been attracting increasing and widespread attention in the field of cryogenic technology because of its compact structure,low vibration,and reliable operation.The gas-... The high-frequency pulse tube cryocooler(HPTC)has been attracting increasing and widespread attention in the field of cryogenic technology because of its compact structure,low vibration,and reliable operation.The gas-coupled HPTC,driven by a single compressor,is currently the simplest and most compact structure.For HPTCs operating below 20 K,in order to obtain the mW cooling capacity,hundreds or even thousands of watts of electrical power are consumed,where radiation heat leakage accounts for a large proportion of their cooling capacity.In this paper,based on SAGE10,a HPTC heat radiation calculation model was first established to study the effects of radiation heat leakage on apparent performance parameters(such as temperature and cooling capacity),and internal parameters(such as enthalpy flow and gas distribution)of the gas-coupled HPTC.An active thermal insulation method of cascade utilization of the cold energy of the system was proposed for the gas-coupled HPTC.Numerical simulations indicate that the reduction of external radiation heat leakage cannot only directly increase the net cooling power,but also decrease the internal gross losses and increase the mass and acoustic power in the lower-temperature section,which further enhances the refrigeration performance.The numerical calculation results were verified by experiments,and the test results showed that the no-load temperature of the developed cryocooler prototype decreased from 15.1 K to 6.4 K,and the relative Carnot efficiency at 15.5 K increased from 0.029%to 0.996%when substituting the proposed active method for the traditional passive method with multi-layer thermal insulation materials. 展开更多
关键词 radiation heat leakage active thermal insulation cascade utilization cold energy performance improvement CRYOCOOLER
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部