期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
A novel method for the spectrophotometric determination of cefradine by using sodium nitroprusside as chromogenic reagent 被引量:2
1
作者 Hua Zhang Ling Li Wu +1 位作者 Quan Min Li xin zhen du 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第12期1470-1474,共5页
一个新奇方法被把钠 nitroprusside 用作发色的试剂为 cefradine 的决心开发。实验显示一个带赤褐色的产品被 cefradine 的反应在基本答案与钠 nitroprusside 形成,并且带赤褐色的产品的最大的吸收波长(最大) 是 505 nm。并且为有钠 ni... 一个新奇方法被把钠 nitroprusside 用作发色的试剂为 cefradine 的决心开发。实验显示一个带赤褐色的产品被 cefradine 的反应在基本答案与钠 nitroprusside 形成,并且带赤褐色的产品的最大的吸收波长(最大) 是 505 nm。并且为有钠 nitroprusside 的 cefradine 的反应的 tetradecyl 本甲基 dimethyl 铵氯化物的促进感受性是显著的。明显的臼齿的吸收系数(505 ) 是 2.81 展开更多
关键词 钠硝普盐 分光谱测量 反应物 方法
下载PDF
Chiral Separation of Erythromycin as a New Chiral Selector on CE 被引量:1
2
作者 Jing Guo HOU Tian Xi HE +4 位作者 Xiao Qian HAN xin zhen du Xue Feng MAO Hua Ling DENG Jin Zhang GAO 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第3期280-282,共3页
Erythromycin as a new chiral selector was first used for chrial separation of four derivatives of biphenyldimethylester enantiomers on CE. The influence of pH, the chiral selector concentration and organic modifiers ... Erythromycin as a new chiral selector was first used for chrial separation of four derivatives of biphenyldimethylester enantiomers on CE. The influence of pH, the chiral selector concentration and organic modifiers were preliminarily studied. Experiments show that the erythromycin as chiral selector is useful to CE. 展开更多
关键词 ENANTIOMER ERYTHROMYCIN chiral selector CE.
下载PDF
Study on Room-Temperature Phosphorescence of 1-Bromonaphthalene in Media of Surfactant and β-Cyclodextrin
3
作者 xin zhen du Yun Bao JLANG Xian Zhi mANG and Guo zhen CHLN(The Research Laboratory of SEDC of Analytical Science for Matenal and Life ChemistryDepartmen: of Chermstn. Xiamer University. kiames 361005) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第5期431-434,共4页
Sdrictants(S) induced room-ternperature phorphorescence(RTP) frorn l-bromonaplithalene(l-BrN) in aerated aqueous solutions of o-cyclodextha(β-CD) hasbeco mvestigated m detail. lt has been fotmd that the partial incIu... Sdrictants(S) induced room-ternperature phorphorescence(RTP) frorn l-bromonaplithalene(l-BrN) in aerated aqueous solutions of o-cyclodextha(β-CD) hasbeco mvestigated m detail. lt has been fotmd that the partial incIu5ion and coil ofhydIocarbon chain of edctans at the mouth of the 6-CD ca\4ty' is reSPoedle foTbright RTP 展开更多
关键词 MEDIA Cyclodextrin Study on Room-Temperature Phosphorescence of 1-Bromonaphthalene in Media of Surfactant and
下载PDF
STUDIES ON DERIVATIVE FLUORIMETRY Ⅲ. DETERMINATION OF TRACE AMOUNT OF TERBIUM IN THE PRESENCE OF SODIUM DODECYL SULFONATE
4
作者 xin zhen du Jin Zhang GAO +1 位作者 Jing Wan KANG Guang Bi BAI 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第10期821-824,共4页
The derivative fluorimetric characteristics of Tb—SDS and Tb—SDS—phenanthroline systems have been studied. The optimum conditions were obtained. The 2nd—derivative spectrofluorimetric method in the systems has bee... The derivative fluorimetric characteristics of Tb—SDS and Tb—SDS—phenanthroline systems have been studied. The optimum conditions were obtained. The 2nd—derivative spectrofluorimetric method in the systems has been applied to the determination of trace amounts of terbium, in rare earth ore and their oxides. The results are satisfactory. 展开更多
下载PDF
STUDIES ON DERIVATIVE FLUORIMETRY Ⅳ. DETERMINATION OF TRACE AMOUNT OF TERBIUM THROUGH ITS TERNARY COMPLEX WITH ACETYLACETONE AND EDTA IN THE PRESENCE OF CETYL PYRIDINIUM CHLORIDE
5
作者 xin zhen du Jin Zhang GAO +1 位作者 Jing Wan KANG Guang Bi BAI 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第10期825-828,共4页
Terbium can form a ternary complex having a ratio of 1:1:1 with acetylacetone and EDTA. By adding cetyl pyridinium chloride into the above system, a marked enhancement of fluorescence intensity is observed and the ter... Terbium can form a ternary complex having a ratio of 1:1:1 with acetylacetone and EDTA. By adding cetyl pyridinium chloride into the above system, a marked enhancement of fluorescence intensity is observed and the ternary complex becomes more stable than before. For analytical application, the derivative spectrofluorimetric method has high sensitivity and the effect of foreign ions is very low. The optimum conditions were obtained. The calibration graph is linear over 5~100μg/mL. 展开更多
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部