The three-layer structure model of the fiber Bragg grating is proposed in this paper. And through experimental study and reasoning calculation to verify the three layer structure of the optical waveguide model, so the...The three-layer structure model of the fiber Bragg grating is proposed in this paper. And through experimental study and reasoning calculation to verify the three layer structure of the optical waveguide model, so the sensitivity characteristic of the Bragg wavelength to the refractive index of chemical solution is obtained. And the relationships between the concentration and the shift of Bragg wavelength of sucrose, ethanol, and Nacl solution are achieved. Finally the shifts of the Bragg wavelength with the external concentration are obtained by experiments. A kind of simple structure, small size, good stability, high sensitivity chemical concentration sensor is obtained.展开更多
Objective:To investigate the value of contrast-enhanced transcranial doppler(c-TCD)in the diagnosis of patent foramen ovale(PFO)of patients with migraine and cryptogenic stroke.Methods:A retrospective analysis of 160 ...Objective:To investigate the value of contrast-enhanced transcranial doppler(c-TCD)in the diagnosis of patent foramen ovale(PFO)of patients with migraine and cryptogenic stroke.Methods:A retrospective analysis of 160 patients undergoing c-TCD monitoring in our hospital from June 2014 to June 2019 was performed.Among them,there were 80 cases of patients with migraine(38 cases with aura and 42 cases without aura)in group A,and 80 cases of patients with cryptogenic stroke in group B.The positive detectable rate of PFO in the two groups were calculated and analyzed.Results:The detectable rate was 50.00%in group A,and 40.00%in group B.There was no statistical significance between the two groups(P>0.05).Among them,the detectable rate of PFO in migraine with aura in group A(62.50%)was higher than that in group B(37.50%).The difference was statistically significant(P<0.05);In the two groups of PFO-positive patients,the difference didn’t have statistical significance,comparing the proportion of the inherent type to that of potential type(P>0.05);There was no statistical significance of the difference between the RLS incidence of grade I and that of grade II among two groups of PFO-positive patients(P>0.05);the incidence of RLS in grade III in group B(50.00%)was higher than that in group A(25.00%),and the difference was statistically significant(P<0.05).Conclusion:c-TCD can accurately screen migraine and cryptogenic stroke caused by PFO,and grade and classify it as a clinical diagnosis of migraine and cryptogenic caused by PFO.It can also act as a objective reference of estimating the effect of treatment in different diseases and preventing cryptogenic stroke.展开更多
Objective:To study the value of the wearable single-lead remote monitoring device with the scatterplot in chronic disease management.Methods:dmitted into 435 residents accord with the inclusion criteria of 20 primary ...Objective:To study the value of the wearable single-lead remote monitoring device with the scatterplot in chronic disease management.Methods:dmitted into 435 residents accord with the inclusion criteria of 20 primary medical institutions of Yinchuan city,and grouped voluntarily by the implementation schemes were grouped voluntarily according to the implementation schemes.According to one of the three implementation schemes selected,the general practitioner guided the subjects to take on the wearable single-lead remote monitoring device,collecting and uploading the EEG data,then diagnosed and analyzed by the synchronously generated ECG scatterplot,finally,summarized the incidence and the categories,analyzed the differences among these three groups.Results:Among 435 subjects,there were 61 normal patients and 374 arrhythmias with the detection rate of 85.98%;and among the 1672 data collected,there were 606 normal data and 1066 arrhythmia with the detection rate of 63.76%;880 data in total 333 cases with atrial premature beat;442 data in total 215 cases with occasional ventricular premature beat;37 data of 22 cases with frequent atrial beat;65 data of 28 cases with frequent ventricular premature beat;13 data of 6 cases with atrial fibrillation;25 data of 15 cases with excitation conduction disorder;2 data of 2 cases with atrial flutter;31 data of 19 cases with ventricular tachycardia;30 data of 16 cases with conduction block;and 14 data of 8 cases with Para systolic rhythm.comparing the detection rate of arrhythmia in three groups,the difference was not statistically significant(P>0.05).Conclusion:The wearable singlelead remote monitoring device with the scatterplot has high application value in cardiovascular chronic disease management.Its effectively screening,validly diagnosing and detailed classifying are helpful to the early intervention,and the protection of the patients’lives.展开更多
文摘The three-layer structure model of the fiber Bragg grating is proposed in this paper. And through experimental study and reasoning calculation to verify the three layer structure of the optical waveguide model, so the sensitivity characteristic of the Bragg wavelength to the refractive index of chemical solution is obtained. And the relationships between the concentration and the shift of Bragg wavelength of sucrose, ethanol, and Nacl solution are achieved. Finally the shifts of the Bragg wavelength with the external concentration are obtained by experiments. A kind of simple structure, small size, good stability, high sensitivity chemical concentration sensor is obtained.
基金Health Commission of Ningxia Hui Autonomous Region(2017-NW-066)。
文摘Objective:To investigate the value of contrast-enhanced transcranial doppler(c-TCD)in the diagnosis of patent foramen ovale(PFO)of patients with migraine and cryptogenic stroke.Methods:A retrospective analysis of 160 patients undergoing c-TCD monitoring in our hospital from June 2014 to June 2019 was performed.Among them,there were 80 cases of patients with migraine(38 cases with aura and 42 cases without aura)in group A,and 80 cases of patients with cryptogenic stroke in group B.The positive detectable rate of PFO in the two groups were calculated and analyzed.Results:The detectable rate was 50.00%in group A,and 40.00%in group B.There was no statistical significance between the two groups(P>0.05).Among them,the detectable rate of PFO in migraine with aura in group A(62.50%)was higher than that in group B(37.50%).The difference was statistically significant(P<0.05);In the two groups of PFO-positive patients,the difference didn’t have statistical significance,comparing the proportion of the inherent type to that of potential type(P>0.05);There was no statistical significance of the difference between the RLS incidence of grade I and that of grade II among two groups of PFO-positive patients(P>0.05);the incidence of RLS in grade III in group B(50.00%)was higher than that in group A(25.00%),and the difference was statistically significant(P<0.05).Conclusion:c-TCD can accurately screen migraine and cryptogenic stroke caused by PFO,and grade and classify it as a clinical diagnosis of migraine and cryptogenic caused by PFO.It can also act as a objective reference of estimating the effect of treatment in different diseases and preventing cryptogenic stroke.
基金The Special Project of Science and technology benefit the people of Ningxia Hui Autonomous Region(2018CMG03015)。
文摘Objective:To study the value of the wearable single-lead remote monitoring device with the scatterplot in chronic disease management.Methods:dmitted into 435 residents accord with the inclusion criteria of 20 primary medical institutions of Yinchuan city,and grouped voluntarily by the implementation schemes were grouped voluntarily according to the implementation schemes.According to one of the three implementation schemes selected,the general practitioner guided the subjects to take on the wearable single-lead remote monitoring device,collecting and uploading the EEG data,then diagnosed and analyzed by the synchronously generated ECG scatterplot,finally,summarized the incidence and the categories,analyzed the differences among these three groups.Results:Among 435 subjects,there were 61 normal patients and 374 arrhythmias with the detection rate of 85.98%;and among the 1672 data collected,there were 606 normal data and 1066 arrhythmia with the detection rate of 63.76%;880 data in total 333 cases with atrial premature beat;442 data in total 215 cases with occasional ventricular premature beat;37 data of 22 cases with frequent atrial beat;65 data of 28 cases with frequent ventricular premature beat;13 data of 6 cases with atrial fibrillation;25 data of 15 cases with excitation conduction disorder;2 data of 2 cases with atrial flutter;31 data of 19 cases with ventricular tachycardia;30 data of 16 cases with conduction block;and 14 data of 8 cases with Para systolic rhythm.comparing the detection rate of arrhythmia in three groups,the difference was not statistically significant(P>0.05).Conclusion:The wearable singlelead remote monitoring device with the scatterplot has high application value in cardiovascular chronic disease management.Its effectively screening,validly diagnosing and detailed classifying are helpful to the early intervention,and the protection of the patients’lives.