Rapid analysis of metal ions and organic compounds in strong acidic solutions is of sustainable interest in multiple disciplines.However,complicated and time-consuming pretreatments are always required for MS analysis...Rapid analysis of metal ions and organic compounds in strong acidic solutions is of sustainable interest in multiple disciplines.However,complicated and time-consuming pretreatments are always required for MS analysis of the compounds in strong acidic solutions.Otherwise,it will result in a weak signal and cause serious damage to the mass spectrometer.Herein,a simple method inherited from nano-ESI MS was developed for rapid analysis of strong acidic solutions.Nanoliter(nL)strong acidic solution was first loaded in the nano-ESI emitter,followed by evaporation to remove the H+and leave the analytes on the wall of the nano-ESI emitter.The evaporation process can be completed within 1 min because of the extremely tiny volume(≤1 nL)of the loaded solution.Then,the dried analytes on the wall of the nano-ESI emitter were redissolved by loading a new solvent,followed by nano-ESI MS analysis.By using this method,metal ions and organic compounds in the strong acidic solution can be detected with low sample consumption(1 nL),high speed(<2 min/sample),high sensitivity(limit of detection=0.2µg/L),and high accuracy(>90%).Proof-of-concept applications of the present method have been successfully achieved for the analysis of gastric juice(pH of the sample=1),monitoring reaction catalyzed by strong acid(pH of the system=0),and micro-area analysis of ores(pH of the extraction solvent=0),showing great application potential in multiple fields.展开更多
基金supported by the National Natural Science Foundation of China(Nos.21864001,21727812 and 21765001)the Ph.D.Start-up Foundation of East China University of Technology(No.DHBK2020001).
文摘Rapid analysis of metal ions and organic compounds in strong acidic solutions is of sustainable interest in multiple disciplines.However,complicated and time-consuming pretreatments are always required for MS analysis of the compounds in strong acidic solutions.Otherwise,it will result in a weak signal and cause serious damage to the mass spectrometer.Herein,a simple method inherited from nano-ESI MS was developed for rapid analysis of strong acidic solutions.Nanoliter(nL)strong acidic solution was first loaded in the nano-ESI emitter,followed by evaporation to remove the H+and leave the analytes on the wall of the nano-ESI emitter.The evaporation process can be completed within 1 min because of the extremely tiny volume(≤1 nL)of the loaded solution.Then,the dried analytes on the wall of the nano-ESI emitter were redissolved by loading a new solvent,followed by nano-ESI MS analysis.By using this method,metal ions and organic compounds in the strong acidic solution can be detected with low sample consumption(1 nL),high speed(<2 min/sample),high sensitivity(limit of detection=0.2µg/L),and high accuracy(>90%).Proof-of-concept applications of the present method have been successfully achieved for the analysis of gastric juice(pH of the sample=1),monitoring reaction catalyzed by strong acid(pH of the system=0),and micro-area analysis of ores(pH of the extraction solvent=0),showing great application potential in multiple fields.