期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Effect of the addition of Al-Ti-C master alloy on the microstructure and microhardness of a cast Al-10Mg alloy
1
作者 Kuibo Yin Xiufang Bian +3 位作者 Na Han xiujun yao Yan Zhao Jiankun Zhou 《Journal of University of Science and Technology Beijing》 CSCD 2006年第2期149-153,共5页
The microstructure and microhardness of a cast Al-10wt%Mg (henceforth Al-10Mg) alloy with 0.2wt% addition of Al- 5Ti-0.25C master alloy were compared with those of a refiner-free alloy of similar chemical compositio... The microstructure and microhardness of a cast Al-10wt%Mg (henceforth Al-10Mg) alloy with 0.2wt% addition of Al- 5Ti-0.25C master alloy were compared with those of a refiner-free alloy of similar chemical composition. It was found that this level of the master alloy addition not only caused an effective grain refinement, but also caused a significant increase in the microhardness of the Al-10Mg alloy. Microchemical analysis revealed that TiC particles existed in the grain center. The relationship between the holding time and grain size was also studied. It shows that the grain refining efficiency is faded observably with the holding time. This is explained in terms of the instability of TiC particles. 展开更多
关键词 Al-Mg alloy Al-Ti-C alloy MICROHARDNESS grain refinement
下载PDF
Analysis of Gas Flow Rate and Pressure Loss of Medical Mask Differential Pressure Tester
2
作者 Zechen Lin Qing Zhang +1 位作者 Jianjun Sun xiujun yao 《Journal of Clinical and Nursing Research》 2022年第4期120-127,共8页
The objective of this study is to find a suitable method to overcome the pressure loss problem in the gas pipe during the gas exchange detection of medical masks.Based on the European Standards EN 14683,the parameters... The objective of this study is to find a suitable method to overcome the pressure loss problem in the gas pipe during the gas exchange detection of medical masks.Based on the European Standards EN 14683,the parameters of a medical mask differential pressure tester were selected,subsequently two schemes of gas pipe layouts were designed,including four kinds of pipe diameter which are 4,5,6.5,and 8mm respectively.Lastly,the models of each scheme were established and imported into Fluent,and the relevant parameters were set for simulation.After data analysis,the results showed that among the four different pipe diameters,the pressure loss of 8mm diameter of the pipe was lower in both the schemes,additionally the pressure loss of the second scheme(the gas pipe was short and smooth)was lower under the same pipe diameter.At the flow rate of v=8L/min,the pressure loss from the inlet to the measurement point is less than 200Pa,and the estimated measurement error is less than 1.5%.In conclusion,shortening the length of the pipe,and increasing the diameter of the pipe can reduce the gas pressure loss,subsequently improve the measurement accuracy of the medical mask differential pressure tester. 展开更多
关键词 Medical mask Differential pressure Flow rate Pressure loss Fluid simulation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部