期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Image reconstruction for the coded aperture system in nuclear safety and security using a Monte Carlo-based system matrix 被引量:1
1
作者 Yue Yu Xiaoli Sun +6 位作者 Zhiming Zhang Shuangquan Liu xiuzuo liang Daowu Li Lei Shuai Tingting Hu Long Wei 《Radiation Detection Technology and Methods》 CSCD 2023年第2期263-270,共8页
Purpose Accurate localization of radioactive materials is critical to nuclear safety and nuclear security.A coded aperture imaging system provides a visualization solution.However,the correlation method has poor recon... Purpose Accurate localization of radioactive materials is critical to nuclear safety and nuclear security.A coded aperture imaging system provides a visualization solution.However,the correlation method has poor reconstruction performance for sources with low counts and for extended sources.Methods In this study,a Monte Carlo optimization-based MLEM algorithm(MC-MLEM)is proposed.The system matrix was obtained by accurate Monte Carlo simulation,so the physical effects such as mask penetration that affect the imaging process were taken into account in the MLEM algorithm.In the simulation process,the normalization of the system matrix was realized by controlling the source at different position of the source plane to have the same activity and emission angle.Results The experimental results showed that compared with the correlation method,the MC-MLEM algorithm could improve the signal-to-noise ratio and angular resolution and locate the source position quickly and accurately under low count conditions.Furthermore,the MC-MLEM algorithm could reconstruct the shape of the extended source and the expected activity ratio of cold-hot sources with large activity differences.Conclusion The MC-MLEM algorithm improved the imaging results and enhanced the reconstruction performance. 展开更多
关键词 Coded aperture System matrix Image reconstruction Low count imaging Extended sources
原文传递
YSO coded aperture camera based on depth of interaction for location correction
2
作者 Yiding Han Xiaopan Jiang +7 位作者 Haohui Tang xiuzuo liang Xuanhou Hu Xianchao Huang Zhiming Zhang Lei Shuai Jing Guo Long Wei 《Radiation Detection Technology and Methods》 CSCD 2023年第4期589-598,共10页
Purpose Coded aperture imaging was a widely used imaging method for radiation sources.However,the traditional gamma camera based on two-dimensional projection information for coded aperture imaging ignored the influen... Purpose Coded aperture imaging was a widely used imaging method for radiation sources.However,the traditional gamma camera based on two-dimensional projection information for coded aperture imaging ignored the influence of the interaction depth of particles and detectors on the projection information,which reduced the imaging quality of the camera to some extent.Therefore,a method of correcting the coded gamma camera based on the interaction depth of particles and detectors is proposed to improve the location accuracy of detectors.Methods The camera developed in this work uses a 7×7 YSO crystal array coupled with two 7×7 Si-PM arrays.The crystal is evenly divided into 11 parts in the depth direction,with a voxel size of 3×3×3 mm3.The coded mask is a 13×13 array,which is a mosaic of two cycles of 7×7 modified uniformly redundant array mask.The depth resolution of the detector is obtained via the subsurface laser engraving dual-end readout method.After obtaining the three-dimensional position information of the interaction point the projection information obtained by the detector is layered,and the image is reconstructed.According to the spatial position information of the detector and the coded mask,the corresponding field of view of each layer of the detector is calculated,and the reconstructed image of each layer is amplified and superimposed according to the ratio of the field of view to obtain the reconstructed image combined with the depth information.Results and conclusion According to Monte Carlo simulation and radiation source imaging experiment results,this method can effectively improve the positioning ability of the detector.For the experimental scenario mentioned in the paper,the location accuracy can be improved by up to 1.54°. 展开更多
关键词 Depth of interaction Coded aperture gamma camera YSO detector Location accuracy
原文传递
A high-position-resolution trajectory detector system for cosmic ray muon tomography:Monte Carlo simulation 被引量:3
3
作者 Jiajia Zhai Haohui Tang +8 位作者 Xianchao Huang Shuangquan Liu Yingjie Wang Chong Li xiuzuo liang Yi Zhang Meichan Feng Zhiming Zhang Long Wei 《Radiation Detection Technology and Methods》 CSCD 2022年第2期244-253,共10页
Purpose The research focuses on the related designing and simulating the high-position-resolution trajectory detector system based on cosmic ray muon tomography.Methods The energy deposition of muon in the detector va... Purpose The research focuses on the related designing and simulating the high-position-resolution trajectory detector system based on cosmic ray muon tomography.Methods The energy deposition of muon in the detector varies with the length of the ionization path.Results The simulation of the submillimeter detector system was designed for muon imaging.The optimal position resolution of the detector reached 0.6 mm.Conclusions The entire research process includes the selection of analysis of parameters affecting system design,designing of two high-position-resolution detectors based on plastic scintillators,implementation of different imaging algorithms and image quality assessment based on different imaging models.It provides a solution based on high positional resolution plastic scintillator detectors for cosmic ray muon scattering imaging. 展开更多
关键词 Cosmic ray Muon tomography Plastic scintillator Position resolution PoCA MLSD-EM
原文传递
Compact MPPC-based coded aperture imaging camera for dual-particle detection 被引量:2
4
作者 Jing Guo Xiaoyu Pang +9 位作者 Jiale Cai Daowu Li Xiaoming Wang Xuanhou Hu Yue Yu Shuangquan Liu xiuzuo liang Yiwen Zhang Lei Shuai Long Wei 《Radiation Detection Technology and Methods》 CSCD 2021年第1期61-70,共10页
Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sen... Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sensitive to both gamma and neutron radiation based on plastic scintillators and multi-pixel photon counters(MPPC).Methods MPPCs coupling with the 13×13 pixelated plastic scintillators one-to-one were utilized to reduce the scale of the CAI system while maintaining good positional performance.The symmetric charge division(SCD)circuit was adopted to reduce the 169 signals output from the MPPC array to 26.Each waveform was collected and processed with four Domino Ring Sampler 4(DRS4)chips and two 16-channel analog-to-digital converter(ADC)modules.As the pulse shapes of fast neutrons would be broadened after elastic scattering multiple times in the scintillators,the Anger-Logic method was applied to eliminate multiple elastic scattering events so that good pulse shape discrimination(PSD)performance can be achieved.Results The imaging and detection ability of the camerawas evaluated using the 241Am-Be(5.9×10^(5) n/s)neutron source and 137Cs(370 MBq)gammasource.The camera can be used to detect fast neutrons(0.5–10 MeV)and gammarays(0.2–2.5MeV).Furthermore,it can implement efficient neutron/gamma PSD capabilities in the mixed-field environment.The figure of merit(FOM)of the camera calculated at 400keVee energy cut is 0.93.Conclusion A compact MPPC-based CAI camera was designed to detect and discriminate fast neutrons and gamma rays.Its good PSD performance was well suited to distinguish fast neutrons from gamma rays in a dual-particle environment.The portable design makes it promising for complex monitoring scenarios in nuclear security. 展开更多
关键词 Coded aperture imaging Fast neutron imaging Gamma imaging n-γdiscrimination
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部