Aim: To report a short-time result of three-piece inflatable penile prosthesis (IPP) implantation on treating patients with organic erectile dysfunction (ED). Methods: Three-piece IPPs were implanted in 42 Chine...Aim: To report a short-time result of three-piece inflatable penile prosthesis (IPP) implantation on treating patients with organic erectile dysfunction (ED). Methods: Three-piece IPPs were implanted in 42 Chinese patients with ED refractory to systemic treatment between May 2002 and May 2004. The etiologies of ED were neurogenic (28 with paraplegia and seven with traumatic nervi-erigentes injury), congenital venous leakage (5 cases), fibrosis of corpus cavernosum (lcase) and Klinefelter's syndrome (1 case). The follow-up period ranged from 24 to 57 months. Results: Implantation procedures were successfully performed upon all 42 patients. The length of implanted prosthesis was from 13 cm to 18 cm, and the diameter was 1 cm. The implanted prosthesis was made by the Medical Instrumentation Company of Muping (Muping, Shandong, China). Localized infection occurred in only one patient and mechanical complications occurred in five patients. Coitus could be performed in 41 cases (97.6%). Three patients with congenital venous leakage made their spouses pregnant after implantation. Conclusion: Implantation of three-piece IPP is an effective and safe modality for treating patients with ED. It can be well accepted by Chinese patients because of its efficacy.展开更多
We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal...We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg), prostaglandin E1 (10 μg), and lidocaine (2%, 0.5-1 ml), the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades Ⅴ to Ⅱ). Then, the patients were given oral sildenafil (50-100 mg) and scored according to the International Index of Erectile Function (IIEF-5) questionnaire. The number of patients with penile rigidities of Schramek Grades Ⅱ to Ⅴ was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P 〈 0.05), the peak systolic velocity (r= 0.45, P〈 0.05), and penile rigidity (r= 0.75, P〈 0.05), and was negatively correlated with the end diastolic velocity (r = -0.74, P 〈 0.05). For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction.展开更多
The purpose of this study was to determine the diagnostic accuracy of serum inhibin B(INHB)as a predictor of the retrieval outcome of testicular haploid gametes(spermatids and testicular spermatozoa)in nonobstructive ...The purpose of this study was to determine the diagnostic accuracy of serum inhibin B(INHB)as a predictor of the retrieval outcome of testicular haploid gametes(spermatids and testicular spermatozoa)in nonobstructive azoospermic men.Serum hormone levels,testicular volume,and histological evaluation were performed in 403 Chin ese non obstructive azoospermic men.Testicular haploid gamete was successfully retrieved in 213 of 403 patients(52.85%).The haploid gamete group always had higher INHB levels than the non-haploid gamete group.According to the receiver operating characteristic(ROC)curve analysis,INHB was a good predictor of testicular haploid gamete retrieval outcome in all patients(sensitivity:77.93%and specificity:91.58%)and patients with normal follicle-stimulating hormone(FSH;sensitivity:88.52%and specificity:70.83%).The area under the ROC curve(AUC)of INHB was similar to that of FSH in all patients or patients with normal FSH.In patients with elevated FSH,INHB was superior to FSH in predicting the presence of haploid gamete(AUC:0.73 vs 0.55,P<0.05),with a sensitivity of 60.00%and a specificity of 80.28%.It con eluded that serum INHB as an effective marker for spermatoge nesis was a sign ificant predictor of testicular haploid gamete retrieval outcomes in nonobstructive azoospermic men.Especially,INHB is superior to FSH in predicting the presenee of haploid gamete in the patients with elevated FSH.展开更多
文摘Aim: To report a short-time result of three-piece inflatable penile prosthesis (IPP) implantation on treating patients with organic erectile dysfunction (ED). Methods: Three-piece IPPs were implanted in 42 Chinese patients with ED refractory to systemic treatment between May 2002 and May 2004. The etiologies of ED were neurogenic (28 with paraplegia and seven with traumatic nervi-erigentes injury), congenital venous leakage (5 cases), fibrosis of corpus cavernosum (lcase) and Klinefelter's syndrome (1 case). The follow-up period ranged from 24 to 57 months. Results: Implantation procedures were successfully performed upon all 42 patients. The length of implanted prosthesis was from 13 cm to 18 cm, and the diameter was 1 cm. The implanted prosthesis was made by the Medical Instrumentation Company of Muping (Muping, Shandong, China). Localized infection occurred in only one patient and mechanical complications occurred in five patients. Coitus could be performed in 41 cases (97.6%). Three patients with congenital venous leakage made their spouses pregnant after implantation. Conclusion: Implantation of three-piece IPP is an effective and safe modality for treating patients with ED. It can be well accepted by Chinese patients because of its efficacy.
基金ACKNOWLEDGMENTS This work was partly supported by: projects of Technology Development Program of Shandong Province (No. 2014GSF 118033) Youth Funds of National Natural Science Foundation of China (No. 30901488)+2 种基金 Doctor Start Fund of Natural Science Foundation of Guangdong Province (No. 9451008901003001)Medical Science and Technology Research Foundation of Guangdong Province (No. A2008189) Foundation for Outstanding Young Scientist in Shandong Province (No. 2004BS02019) and Independent Innovation Funds of Center for Reproductive Medicine of Shandong University. These organizations aided in the design and conduct of the study as well as in the collection, management, and analysis of the data.
文摘We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg), prostaglandin E1 (10 μg), and lidocaine (2%, 0.5-1 ml), the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades Ⅴ to Ⅱ). Then, the patients were given oral sildenafil (50-100 mg) and scored according to the International Index of Erectile Function (IIEF-5) questionnaire. The number of patients with penile rigidities of Schramek Grades Ⅱ to Ⅴ was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P 〈 0.05), the peak systolic velocity (r= 0.45, P〈 0.05), and penile rigidity (r= 0.75, P〈 0.05), and was negatively correlated with the end diastolic velocity (r = -0.74, P 〈 0.05). For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction.
文摘The purpose of this study was to determine the diagnostic accuracy of serum inhibin B(INHB)as a predictor of the retrieval outcome of testicular haploid gametes(spermatids and testicular spermatozoa)in nonobstructive azoospermic men.Serum hormone levels,testicular volume,and histological evaluation were performed in 403 Chin ese non obstructive azoospermic men.Testicular haploid gamete was successfully retrieved in 213 of 403 patients(52.85%).The haploid gamete group always had higher INHB levels than the non-haploid gamete group.According to the receiver operating characteristic(ROC)curve analysis,INHB was a good predictor of testicular haploid gamete retrieval outcome in all patients(sensitivity:77.93%and specificity:91.58%)and patients with normal follicle-stimulating hormone(FSH;sensitivity:88.52%and specificity:70.83%).The area under the ROC curve(AUC)of INHB was similar to that of FSH in all patients or patients with normal FSH.In patients with elevated FSH,INHB was superior to FSH in predicting the presence of haploid gamete(AUC:0.73 vs 0.55,P<0.05),with a sensitivity of 60.00%and a specificity of 80.28%.It con eluded that serum INHB as an effective marker for spermatoge nesis was a sign ificant predictor of testicular haploid gamete retrieval outcomes in nonobstructive azoospermic men.Especially,INHB is superior to FSH in predicting the presenee of haploid gamete in the patients with elevated FSH.