期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Fully sprayed MXene-based high-performance flexible piezoresistive sensor for image recognition
1
作者 Zhi-Dong Zhang xue-feng zhao +4 位作者 Qing-Chao Zhang Jie Liang Hui-Nan Zhang Tian-Sheng Zhang Chen-Yang Xue 《Nano Materials Science》 EI CAS CSCD 2024年第1期77-85,共9页
High-performance flexible pressure sensors provide comprehensive tactile perception and are applied in human activity monitoring,soft robotics,medical treatment,and human-computer interface.However,these flexible pres... High-performance flexible pressure sensors provide comprehensive tactile perception and are applied in human activity monitoring,soft robotics,medical treatment,and human-computer interface.However,these flexible pressure sensors require extensive nano-architectural design and complicated manufacturing and are timeconsuming.Herein,a highly sensitive,flexible piezoresistive tactile sensor is designed and fabricated,consisting of three main parts:the randomly distributed microstructure on T-ZnOw/PDMS film as a top substrate,multilayer Ti_(3)C_(2)-MXene film as an intermediate conductive filler,and the few-layer Ti_(3)C_(2)-MXene nanosheetbased interdigital electrodes as the bottom substrate.The MXene-based piezoresistive sensor with randomly distributed microstructure exhibits a high sensitivity over a broad pressure range(less than 10 kPa for 175 kPa^(-1))and possesses an out-standing permanence of up to 5000 cycles.Moreover,a 16-pixel sensor array is designed,and its potential applications in visualizing pressure distribution and an example of tactile feedback are demonstrated.This fully sprayed MXene-based pressure sensor,with high sensitivity and excellent durability,can be widely used in,electronic skin,intelligent robots,and many other emerging technologies. 展开更多
关键词 Piezoresistive sensor Ti_(3)C_(2)-MXene T-ZnOw/PDMS film Randomly distributed microstructure
下载PDF
Comparative analysis of two digestive tract reconstruction methods in total laparoscopic radical total gastrectomy
2
作者 Tian-Xiang Dong Dong Wang +10 位作者 Qun zhao Zhi-Dong Zhang xue-feng zhao Bi-Bo Tan Yu Liu Qing-Wei Liu Pei-Gang Yang Ping-An Ding Tao Zheng Yong Li Zi-Jing Liu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第4期1109-1120,共12页
BACKGROUND The incidence of gastric cancer has significantly increased in recent years.Surgical resection is the main treatment,but the method of digestive tract reconstruction after gastric cancer surgery remains con... BACKGROUND The incidence of gastric cancer has significantly increased in recent years.Surgical resection is the main treatment,but the method of digestive tract reconstruction after gastric cancer surgery remains controversial.In the current study,we sought to explore a reasonable method of digestive tract reconstruction and improve the quality of life and nutritional status of patients after surgery.To this end,we statistically analyzed the clinical results of patients with gastric cancer who underwent jejunal interposition double-tract reconstruction(DTR)and esophageal jejunum Roux-en-Y reconstruction(RY).AIM To explore the application effect of DTR in total laparoscopic radical total gastrectomy(TLTG)and evaluate its safety and efficacy.METHODS We collected the relevant data of 77 patients who underwent TLTG at the Fourth Hospital of Hebei Medical University from October 2021 to January 2023.Among them,35 cases were treated with DTR,and the remaining 42 cases were treated with traditional RY.After 1:1 propensity score matching,the cases were grouped into 31 cases per group,with evenly distributed data.The clinical characteristics and short-and long-term clinical outcomes of the two groups were statistically analyzed.RESULTS The two groups showed no significant differences in basic data,intraoperative blood loss,number of lymph node dissections,first defecation time after operation,postoperative hospital stay,postoperative complications,and laboratory examination results on the 1st,3rd,and 5th days after operation.The operation time of the DTR group was longer than that of the RY group[(307.58±65.14)min vs(272.45±62.09)min,P=0.016],but the first intake of liquid food in the DTR group was shorter than that in the RY group[(4.45±1.18)d vs(6.0±5.18)d,P=0.028].The incidence of reflux heartburn(Visick grade)and postoperative gallbladder disease in the DTR group was lower than that in the RY group(P=0.033 and P=0.038).Although there was no significant difference in body weight,hemoglobin,prealbumin,and albumin between the two groups at 1,3 and 6 months after surgery,the diet of patients in the DTR group was better than that in the RY group(P=0.031).CONCLUSION The clinical effect of DTR in TLTG is better than that of RY,indicating that it is a more valuable digestive tract reconstruction method in laparoscopic gastric cancer surgery. 展开更多
关键词 Gastric cancer Jejunal interposition double-tract reconstruction Roux-en-Y reconstruction LAPAROSCOPE
下载PDF
Abraxne对Lewis肺癌小鼠Per2基因及SIRT1因子表达的影响 被引量:1
3
作者 赵雪峰 范娟 +2 位作者 杨玲麟 傅少志 陈琼英 《中国现代医学杂志》 CAS 2018年第29期13-18,共6页
目的探讨白蛋白结合型紫杉醇(Abraxne)对Lewis肺癌模型小鼠生物钟基因Per2、沉默信息调节因子1(SIRT1)表达的影响。方法将60只SPF级C57BL/6雌性小鼠随机分为正常对照组、模型组、紫素组[紫素30 mg/(kg·d)]、Abraxne组[Abraxne 30 m... 目的探讨白蛋白结合型紫杉醇(Abraxne)对Lewis肺癌模型小鼠生物钟基因Per2、沉默信息调节因子1(SIRT1)表达的影响。方法将60只SPF级C57BL/6雌性小鼠随机分为正常对照组、模型组、紫素组[紫素30 mg/(kg·d)]、Abraxne组[Abraxne 30 mg/(kg·d)],每组15只。除正常对照组外,其他各组小鼠于右腋部背侧皮下接种Lewis肺癌细胞(LLC)复制Lewis肺癌小鼠模型。于接种后第5天开始尾静脉注射给药,连续用药10 d,观察各组小鼠体重、肿瘤体积及生物学行为变化。采用实时荧光定量聚合酶链反应和Western blot检测肿瘤组织中Per2、SIRT1 mRNA和蛋白的表达。结果 4组小鼠接种LLC细胞前、接种后第5天、给药后第5和10天的体重变化比较,结果显示:(1)不同时间点的体重有差别(F=17.703,P=0.000);(2) 4组小鼠体重有差别(F=7.976,P=0.000);(3) 4组小鼠体重变化趋势有差别(F=21.641,P=0.000)。模型组、紫素组、Abraxne组小鼠给予Abraxne治疗后第0、2、4、6、8和10天的肿瘤体积比较,结果显示:(1)不同时间点的肿瘤体积有差别(F=35.128,P=0.000);(2) 3组小鼠肿瘤体积有差别(F=8.376,P=0.000);(3) 3组小鼠肿瘤体积变化趋势有差别(F=43.624,P=0.000)。与模型组比较,紫素组和Abraxne组小鼠肿瘤组织中Per2、SIRT1 mRNA和蛋白表达水平升高(P <0.05),且Abraxne组小鼠肿瘤组织中Per2、SIRT1 mRNA和蛋白表达水平高于紫素组(P<0.05)。结论 Abraxne较紫素更能抑制Lewis肺癌小鼠肿瘤生长,其机制可能与生物钟基因Per2、SIRT1的表达被强化有关。 展开更多
关键词 白蛋白结合 紫杉醇 LEWIS肺癌 PER2 SIRT1
下载PDF
Mechanical performance of 22SiMn2TiB steel welded with lowtransformation- temperature filler wire and stainless steel filler wire
4
作者 Zi-dong Lin Kai-jie Song +5 位作者 Zhen Sun Zi-qian Zhu xue-feng zhao Constantinos Goulas Wei Ya Xing-hua Yu 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2024年第4期967-981,共15页
TX-80 low-transformation-temperature(LTT)welding wire was used to replace the traditional ER 307Si welding wire to realize the connection of 22SiMn2TiB armor steel in manual overlay welding.The previously existing iss... TX-80 low-transformation-temperature(LTT)welding wire was used to replace the traditional ER 307Si welding wire to realize the connection of 22SiMn2TiB armor steel in manual overlay welding.The previously existing issues,such as welding cracks,large welding deformation,and severe welding residual stress,were solved to ensure good strength and ductility requirements.In particular,with the same welding conditions,TX-80 LTT wire eliminates welding cracks.It reduces the welding deformation no matter the base pretreatment of pre-setting angle or no pre-setting angle.By comparison,it was found that the microstructure at the TX-80 weld is mainly composed of martensite and a small amount of retained austenite.In contrast,the microstructure of the ER 307Si weld consists of a large amount of austenite and a small amount of skeleton-like ferrite.The variation trend of residual stress and microhardness from the weld to the base were investigated and compared with the mechanical properties of base materials.The TX-80 and the ER 307Si tensile samples elongation is 6.76%and 6.01%,while the ultimate tensile strengths are 877 and 667 MPa,respectively.The average impact toughness at room temperature of the ER 307Si weld is 143.9 J/cm^(2),much higher than that of the TX-80 weld,which is only 36.7 J/cm^(2).The relationship between impact and tensile properties with microstructure species and distribution was established.In addition,the fracture surface of the tensile and the impact samples was observed and analyzed.Deeper dimples,fewer pores,larger radiation zone,and shear lips of TX-80 samples indicate better tensile ductility and worse impact toughness than those of ER 307Si weld. 展开更多
关键词 Low-transformation-temperature material 22SiMn2TiB steel Welding deformation Residual stress Martensitic transformation Mechanical property
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部