Objective Sepsis is considered a major cause of health loss in children and had high mortality and morbidity.Currently,there is no reliable model for predicting the prognosis of pediatric patients with sepsis.This stu...Objective Sepsis is considered a major cause of health loss in children and had high mortality and morbidity.Currently,there is no reliable model for predicting the prognosis of pediatric patients with sepsis.This study aimed to analyze the clinical characteristics of sepsis in children and assess the risk factors associated with poor prognosis in pediatric sepsis patients to identify timely interventions and improve their outcomes.Methods This study analyzed the clinical indicators and laboratory results of septic patients hospitalized in the Pediatric Intensive Care Unit of Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from January 1,2019,to December 31,2021.Risk factors for sepsis were identified by logistic regression analyses.Results A total of 355 children with sepsis were enrolled,with 333 children(93.8%)in the good prognosis group,and 22 children(6.2%)in the poor prognosis group.Among them,there were 255 patients(71.8%)in the sepsis group,and 100 patients(28.2%)in the severe sepsis group.The length of hospital stay in the poor prognosis group was longer than that in the good prognosis group(P<0.01).The levels of interleukin 1β(IL-1β)in the poor prognosis group were higher than those in the good prognosis group(P>0.05),and the platelet(PLT),albumin(ALB),and hemoglobin(Hb)levels were lower in the poor prognosis group(P<0.01).The IL-8 levels in the severe sepsis group were higher than those in the sepsis group(P<0.05).Multiple logistic regression analysis suggested that lower Hb levels,ALB levels,peak PLT counts,and higher IL-1βlevels were independent risk factors for poor prognosis in children with sepsis.Conclusion Lower Hb,ALB,and PLT counts and elevated IL-1βare independent risk factors for poor prognosis in children with sepsis.展开更多
This paper presents the design,fabrication,and characterization of cantilever-type resonators with a novel stacked structure.Aluminum nitride is adopted as the material for both the structural layer and the piezoelect...This paper presents the design,fabrication,and characterization of cantilever-type resonators with a novel stacked structure.Aluminum nitride is adopted as the material for both the structural layer and the piezoelectric layer;this simplifies the fabrication process and improves the quality factor of the resonator.Both in-plane and out-of-planeflexural modes were investigated.The effect of the structural dimensions and electrode patterns on the resonator’s performance were also studied.Finite-element simulations and experiments examining anchor loss and thermoelastic damping,which are the main loss mechanisms affecting the quality factor of these resonators,were carried out.The optimal structural dimensions and electrode patterns of the cantilever-type resonators are presented.A quality factor of 7922 with a motional impedance of 88.52 kΩand a quality factor of 8851 with a motional impedance of 67.03 kΩwere achieved for the in-plane and out-of-planeflexural-mode resonators,respectively.The proposed resonator design will contribute to the development of high-performance devices such as accelerometers,gyroscopes,and pressure sensors.展开更多
Objective:To analyze the effect of perioperative comfort care for patients with hysteromyomectomy(HYS).Methods:Seventy cases of HYS patients admitted to our hospital from October 2022 to October 2023 were randomly sel...Objective:To analyze the effect of perioperative comfort care for patients with hysteromyomectomy(HYS).Methods:Seventy cases of HYS patients admitted to our hospital from October 2022 to October 2023 were randomly selected and divided into Group A(control group,35 cases,conventional care)and Group B(observation group 35 cases,comfort care).The effects of the two groups before and after nursing care were compared.Results:The self-rating anxiety(SAS)scores,exercise of self-care agency(ESCA)scores,and nursing satisfaction scores at the time of discharge of Group B were better than in Group A after nursing care(P<0.05).Conclusion:Perioperative comfort care for HYS patients improved the patient’s adverse emotions,self-care ability,and nursing satisfaction.展开更多
We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3&...We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3×10^(−17) and an instability of 4.8×10^(−15)/√τ.Referenced to a stationary clock of TOC-729-1,the geopotential difference measurements are realized by moving TOC-729-3 to three different locations and the relevant altitude differences are measured with uncertainties at the level of 20 cm.After correcting the systematic shifts(including gravitational red shift),the two-clock frequency difference is measured to be–0.7(2.2)×10^(−17),considering both the statistic(1.0×10^(−17))and the systematic(1.9×10^(−17))uncertainties.The frequency difference between these two clocks is within their respective uncertainties,verifying the reliability of transportable ^(40)Ca^(+) optical clocks at the low level of 10^(−17).展开更多
This paper is focused on electrode design for piezoelectric tuning fork resonators.The relationship between the performance and electrode pattern of aluminum nitride piezoelectric tuning fork resonators vibrating in t...This paper is focused on electrode design for piezoelectric tuning fork resonators.The relationship between the performance and electrode pattern of aluminum nitride piezoelectric tuning fork resonators vibrating in the in-plane flexural mode is investigated based on a set of resonators with different electrode lengths,widths,and ratios.Experimental and simulation results show that the electrode design impacts greatly the multimode effect induced from torsional modes but has little influence on other loss mechanisms.Optimizing the electrode design suppresses the torsional mode successfully,thereby increasing the ratio of impedance at parallel and series resonant frequencies(R_(p)/R_(s))by more than 80%and achieving a quality factor(Q)of 7753,an effective electromechanical coupling coefficient(kt_(eff)^(2))of 0.066%,and an impedance at series resonant frequency(R_(m))of 23.6 kΩ.The proposed approach shows great potential for high-performance piezoelectric resonators,which are likely to be fundamental building blocks for sensors with high sensitivity and low noise and power consumption.展开更多
Low electronic conductivity and large volume changes during the(de)lithiation process are the two main challenges for ZnO anode materials used for lithium-ion batteries(LIB).Here,a free-standing,flexible,and binder-fr...Low electronic conductivity and large volume changes during the(de)lithiation process are the two main challenges for ZnO anode materials used for lithium-ion batteries(LIB).Here,a free-standing,flexible,and binder-free LIB electrode composed of ZnO nanorods and carbon cloth(CC)is fabricated.This is then decorated with Ag nanoparticles and finally coated by an amorphous carbon layer to form the hybrid electrode:(C@(Ag&ZnO)).The voids among the nanorods are sufficient to accommodate the volume expansion of the ZnO while the flexible CC,which acts as the current collector,relieves the volume change-induced stress.The Ag nanoparticles are effective in improving the conductivity.This composite electrode shows excellent LIB performance with a stable long cycling life over 500 cycles with a reversible capacity of 1093 mAh g^(-1)at a current density of 200 mA g^(-1).It also shows good rate performance with reversible capacity of 517 mAh g^(-1)under a high-current density of 5000 mA g^(-1).In situ Raman spectroscopy is conducted to investigate the contributions of the amorphous carbon layer to the capacity of the whole electrode and the synergy between the CC and ZnO nanorods.展开更多
基金supported by the Health Commission of Hubei Province(No.WJ2023M005)Hubei Association of Pathophysiology(No.2021HBAP004).
文摘Objective Sepsis is considered a major cause of health loss in children and had high mortality and morbidity.Currently,there is no reliable model for predicting the prognosis of pediatric patients with sepsis.This study aimed to analyze the clinical characteristics of sepsis in children and assess the risk factors associated with poor prognosis in pediatric sepsis patients to identify timely interventions and improve their outcomes.Methods This study analyzed the clinical indicators and laboratory results of septic patients hospitalized in the Pediatric Intensive Care Unit of Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from January 1,2019,to December 31,2021.Risk factors for sepsis were identified by logistic regression analyses.Results A total of 355 children with sepsis were enrolled,with 333 children(93.8%)in the good prognosis group,and 22 children(6.2%)in the poor prognosis group.Among them,there were 255 patients(71.8%)in the sepsis group,and 100 patients(28.2%)in the severe sepsis group.The length of hospital stay in the poor prognosis group was longer than that in the good prognosis group(P<0.01).The levels of interleukin 1β(IL-1β)in the poor prognosis group were higher than those in the good prognosis group(P>0.05),and the platelet(PLT),albumin(ALB),and hemoglobin(Hb)levels were lower in the poor prognosis group(P<0.01).The IL-8 levels in the severe sepsis group were higher than those in the sepsis group(P<0.05).Multiple logistic regression analysis suggested that lower Hb levels,ALB levels,peak PLT counts,and higher IL-1βlevels were independent risk factors for poor prognosis in children with sepsis.Conclusion Lower Hb,ALB,and PLT counts and elevated IL-1βare independent risk factors for poor prognosis in children with sepsis.
基金supported in part by the National Key Research and Development Program of China(Grant No.2020YFB2008800)in part by the Nanchang Institute for Microtechnology of Tianjin University.
文摘This paper presents the design,fabrication,and characterization of cantilever-type resonators with a novel stacked structure.Aluminum nitride is adopted as the material for both the structural layer and the piezoelectric layer;this simplifies the fabrication process and improves the quality factor of the resonator.Both in-plane and out-of-planeflexural modes were investigated.The effect of the structural dimensions and electrode patterns on the resonator’s performance were also studied.Finite-element simulations and experiments examining anchor loss and thermoelastic damping,which are the main loss mechanisms affecting the quality factor of these resonators,were carried out.The optimal structural dimensions and electrode patterns of the cantilever-type resonators are presented.A quality factor of 7922 with a motional impedance of 88.52 kΩand a quality factor of 8851 with a motional impedance of 67.03 kΩwere achieved for the in-plane and out-of-planeflexural-mode resonators,respectively.The proposed resonator design will contribute to the development of high-performance devices such as accelerometers,gyroscopes,and pressure sensors.
基金Research project of Sichuan Maternal and Child Health Association(No.:22FXYB12)Research project of Sichuan Health and Family Planning Commission(No.:16PJ399)。
文摘Objective:To analyze the effect of perioperative comfort care for patients with hysteromyomectomy(HYS).Methods:Seventy cases of HYS patients admitted to our hospital from October 2022 to October 2023 were randomly selected and divided into Group A(control group,35 cases,conventional care)and Group B(observation group 35 cases,comfort care).The effects of the two groups before and after nursing care were compared.Results:The self-rating anxiety(SAS)scores,exercise of self-care agency(ESCA)scores,and nursing satisfaction scores at the time of discharge of Group B were better than in Group A after nursing care(P<0.05).Conclusion:Perioperative comfort care for HYS patients improved the patient’s adverse emotions,self-care ability,and nursing satisfaction.
基金Project supported by the Basic Frontier Science Research Program of Chinese Academy of Sciences (Grant No.ZDBS-LY-DQC028)the National Key Research and Development Program of China (Grant No.2017YFA0304404)the National Natural Science Foundation of China (Grant No.11674357)。
文摘We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3×10^(−17) and an instability of 4.8×10^(−15)/√τ.Referenced to a stationary clock of TOC-729-1,the geopotential difference measurements are realized by moving TOC-729-3 to three different locations and the relevant altitude differences are measured with uncertainties at the level of 20 cm.After correcting the systematic shifts(including gravitational red shift),the two-clock frequency difference is measured to be–0.7(2.2)×10^(−17),considering both the statistic(1.0×10^(−17))and the systematic(1.9×10^(−17))uncertainties.The frequency difference between these two clocks is within their respective uncertainties,verifying the reliability of transportable ^(40)Ca^(+) optical clocks at the low level of 10^(−17).
基金supported in part by the National Key Research and Development Program of China (Grant No.2020YFB2008800)the Nanchang Institute for Microtechnology of Tianjin University。
文摘This paper is focused on electrode design for piezoelectric tuning fork resonators.The relationship between the performance and electrode pattern of aluminum nitride piezoelectric tuning fork resonators vibrating in the in-plane flexural mode is investigated based on a set of resonators with different electrode lengths,widths,and ratios.Experimental and simulation results show that the electrode design impacts greatly the multimode effect induced from torsional modes but has little influence on other loss mechanisms.Optimizing the electrode design suppresses the torsional mode successfully,thereby increasing the ratio of impedance at parallel and series resonant frequencies(R_(p)/R_(s))by more than 80%and achieving a quality factor(Q)of 7753,an effective electromechanical coupling coefficient(kt_(eff)^(2))of 0.066%,and an impedance at series resonant frequency(R_(m))of 23.6 kΩ.The proposed approach shows great potential for high-performance piezoelectric resonators,which are likely to be fundamental building blocks for sensors with high sensitivity and low noise and power consumption.
基金support from National Natural Science Foundation of China(Nos:11874144,12174092 and U21A20500)Hubei Provincial Department of Science and Technology(No.2019CFA079)+1 种基金Wuhan Science and Technology Bureau(2020010601012163)Overseas Expertise Introduction Center for Discipline Innovation(D18025).
文摘Low electronic conductivity and large volume changes during the(de)lithiation process are the two main challenges for ZnO anode materials used for lithium-ion batteries(LIB).Here,a free-standing,flexible,and binder-free LIB electrode composed of ZnO nanorods and carbon cloth(CC)is fabricated.This is then decorated with Ag nanoparticles and finally coated by an amorphous carbon layer to form the hybrid electrode:(C@(Ag&ZnO)).The voids among the nanorods are sufficient to accommodate the volume expansion of the ZnO while the flexible CC,which acts as the current collector,relieves the volume change-induced stress.The Ag nanoparticles are effective in improving the conductivity.This composite electrode shows excellent LIB performance with a stable long cycling life over 500 cycles with a reversible capacity of 1093 mAh g^(-1)at a current density of 200 mA g^(-1).It also shows good rate performance with reversible capacity of 517 mAh g^(-1)under a high-current density of 5000 mA g^(-1).In situ Raman spectroscopy is conducted to investigate the contributions of the amorphous carbon layer to the capacity of the whole electrode and the synergy between the CC and ZnO nanorods.