To identify potential serum biomarkers that could be used to discriminate lung cancers from normal. Methods Proteomic spectra of twenty-eight serum samples from patients with non-small cell lung cancer and twelve f...To identify potential serum biomarkers that could be used to discriminate lung cancers from normal. Methods Proteomic spectra of twenty-eight serum samples from patients with non-small cell lung cancer and twelve from normal individuals were generated by SELDI (Surfaced Enhanced Laser Desorption/Ionization) Mass Spectrometry. Anion-exchange columns were used to fractionate the sera into 6 designated pH groups. Two different types of protein chip arrays, IMAC-Cu and WCX2, were employed. Samples were examined in PBSII Protein Chip Reader (Ciphergen Biosystem Inc) and the discriminatory profiling between cancer and normal samples was analyzed with Biomarker Pattern software. Results Five distinct potential lung cancer biomarkers with higher sensitivity and specificity were found, with four common biomarkers in both IMAC-Cu and WCX2 chip; the remaining biomarker occurred only in WCX2 chip. Two biomarkers were up-regulated while three biomarkers were down-regulated in the serum samples from patients with non-small cell lung cancer. The sensitivities provided by the individual biomarkers were 75%-96.43% and specificities were 75%-100%. Conclusions The preliminary results suggest that serum is a capable resource for detecting specific non-small cell lung cancer biomarkers. SELDI mass spectrometry is a useful tool for the detection and identification of new potential biomarker of non-small cell lung cancer in serum.展开更多
A parametric model of cutting temperature generated in end milling process is developed according to the thermal mechanism of end milling as an intermittent operation, which periodically repeats the cycle of heating u...A parametric model of cutting temperature generated in end milling process is developed according to the thermal mechanism of end milling as an intermittent operation, which periodically repeats the cycle of heating under cutting and cooling under non-cutting. It shows that cutting speed and the tool-workpiece engagement condition are determinative for tool temperature in the operation. The suggested model was investigated by tests of AlTiN coated endmill machining hardened die steel JIS SKD61, where cutting temperature on the flank face of tool was measured with an optical fiber type radiation thermometer. Experimental results show that the tendency of cutting temperature to increase with cutting speed and engagement angle is intensified with the progressing tool wear.展开更多
The trend in die/mold manufacturing at present is towards the hard machining at high speed to replace the electron dis- charge machining. Failure forms of the AlTiN-coated micro-grain carbide endmill when used for th...The trend in die/mold manufacturing at present is towards the hard machining at high speed to replace the electron dis- charge machining. Failure forms of the AlTiN-coated micro-grain carbide endmill when used for the machining of JIS SKD61 (HRC 53), a widely used material in die/mold manufacturing, are investigated. The endmill shows a characteristic that tool life decreases greatly due to the chipping when overload occurs or the rapid increase of wear when over-heat accumulation in cutting edges. As a consequence of the investigation, a strategy to regulate heat generation in the end milling process is proposed. This is accomplished by controlling the cutting arc length, i.e. the length of each flute engaging workpiece in a cutting cycle. Case studies on the slot end milling and comer rounding are conducted. The results show that the proposed strategy suggests the optimal tool path as well as the optimal pitch between successive tool paths under the cutting time criterion.展开更多
基金Science Technology Key Project of Ministry of Education (Grant No.272006) and the Major State Basic Research Project (Grant No.G1999053901).
文摘To identify potential serum biomarkers that could be used to discriminate lung cancers from normal. Methods Proteomic spectra of twenty-eight serum samples from patients with non-small cell lung cancer and twelve from normal individuals were generated by SELDI (Surfaced Enhanced Laser Desorption/Ionization) Mass Spectrometry. Anion-exchange columns were used to fractionate the sera into 6 designated pH groups. Two different types of protein chip arrays, IMAC-Cu and WCX2, were employed. Samples were examined in PBSII Protein Chip Reader (Ciphergen Biosystem Inc) and the discriminatory profiling between cancer and normal samples was analyzed with Biomarker Pattern software. Results Five distinct potential lung cancer biomarkers with higher sensitivity and specificity were found, with four common biomarkers in both IMAC-Cu and WCX2 chip; the remaining biomarker occurred only in WCX2 chip. Two biomarkers were up-regulated while three biomarkers were down-regulated in the serum samples from patients with non-small cell lung cancer. The sensitivities provided by the individual biomarkers were 75%-96.43% and specificities were 75%-100%. Conclusions The preliminary results suggest that serum is a capable resource for detecting specific non-small cell lung cancer biomarkers. SELDI mass spectrometry is a useful tool for the detection and identification of new potential biomarker of non-small cell lung cancer in serum.
文摘A parametric model of cutting temperature generated in end milling process is developed according to the thermal mechanism of end milling as an intermittent operation, which periodically repeats the cycle of heating under cutting and cooling under non-cutting. It shows that cutting speed and the tool-workpiece engagement condition are determinative for tool temperature in the operation. The suggested model was investigated by tests of AlTiN coated endmill machining hardened die steel JIS SKD61, where cutting temperature on the flank face of tool was measured with an optical fiber type radiation thermometer. Experimental results show that the tendency of cutting temperature to increase with cutting speed and engagement angle is intensified with the progressing tool wear.
文摘The trend in die/mold manufacturing at present is towards the hard machining at high speed to replace the electron dis- charge machining. Failure forms of the AlTiN-coated micro-grain carbide endmill when used for the machining of JIS SKD61 (HRC 53), a widely used material in die/mold manufacturing, are investigated. The endmill shows a characteristic that tool life decreases greatly due to the chipping when overload occurs or the rapid increase of wear when over-heat accumulation in cutting edges. As a consequence of the investigation, a strategy to regulate heat generation in the end milling process is proposed. This is accomplished by controlling the cutting arc length, i.e. the length of each flute engaging workpiece in a cutting cycle. Case studies on the slot end milling and comer rounding are conducted. The results show that the proposed strategy suggests the optimal tool path as well as the optimal pitch between successive tool paths under the cutting time criterion.