A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and en...A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and energy,and visualization of various spectra.In comparison to the conventional resonance nuclear reaction system,the key technique is the precise synchronization of the detected counts with the actual scanning voltage(or probing laser frequency).The functions of the system were tested by measuring the hyperfine structure spectra of stable calcium(e.g.,^(40)Ca^(+))and radioactive potassium(e.g.,^(38)K)in the bunched and continuous modes,respectively.This system will be routinely applied and further improved in subsequent laser spectroscopy experiments on unstable isotopes at the Beijing Radioactive Ion-beam Facility(BRIF).展开更多
Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Io...Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Ion-beam Facility(BRIF)and the future High Intensity Heavy-ion Accelerator Facility(HIAF),we developed a collinear laser spectroscopy apparatus integrated with an offline laser ablation ion source and a laser system.The overall performance of this state-of-the-art technique was evaluated,and the system was commissioned using a bunched stable ion beam.The high-resolution optical spectra for the 4s ^(2)S_(1/2)→4p^(2)P_(3/2)(D2)ionic transition of ^(40;42;44;48)Ca isotopes were successfully measured.The extracted isotope shifts relative to ^(40)Ca showed excellent agreement with the literature values.This system is now ready for use at radioactive ion beam facilities such as the BRIF and paves the way for the further development of higher-sensitivity collinear resonance ionization spectroscopy techniques.展开更多
基金supported by the National Natural Science Foundation of China (Nos.12027809,U1967201,11875073,11875074 and 11961141003)National Key R&D Program of China (No.2018YFA0404403)the State Key Laboratory of Nuclear Physics and Technology,Peking University (Nos.NPT2019ZZ02,NPT2020KFY17).
文摘A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and energy,and visualization of various spectra.In comparison to the conventional resonance nuclear reaction system,the key technique is the precise synchronization of the detected counts with the actual scanning voltage(or probing laser frequency).The functions of the system were tested by measuring the hyperfine structure spectra of stable calcium(e.g.,^(40)Ca^(+))and radioactive potassium(e.g.,^(38)K)in the bunched and continuous modes,respectively.This system will be routinely applied and further improved in subsequent laser spectroscopy experiments on unstable isotopes at the Beijing Radioactive Ion-beam Facility(BRIF).
基金supported by the National Natural Science Foundation of China(Nos.12027809,U1967201,11875073,11875074 and 11961141003)National Key R&D Program of China(No.2018YFA0404403)+1 种基金China National Nuclear Corporation(No.FA18000201)the State Key Laboratory of Nuclear Physics and Technology,Peking University(No.NPT2019ZZ02).
文摘Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Ion-beam Facility(BRIF)and the future High Intensity Heavy-ion Accelerator Facility(HIAF),we developed a collinear laser spectroscopy apparatus integrated with an offline laser ablation ion source and a laser system.The overall performance of this state-of-the-art technique was evaluated,and the system was commissioned using a bunched stable ion beam.The high-resolution optical spectra for the 4s ^(2)S_(1/2)→4p^(2)P_(3/2)(D2)ionic transition of ^(40;42;44;48)Ca isotopes were successfully measured.The extracted isotope shifts relative to ^(40)Ca showed excellent agreement with the literature values.This system is now ready for use at radioactive ion beam facilities such as the BRIF and paves the way for the further development of higher-sensitivity collinear resonance ionization spectroscopy techniques.