期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
An All-Fiberized Chirped Pulse Amplification System Based on Chirped Fiber Bragg Grating Stretcher and Compressor
1
作者 Ming-Xiao Wang Ping-xue Li +3 位作者 yang-tao xu Yun-Chen Zhu Shun Li Chuan-Fei Yao 《Chinese Physics Letters》 SCIE EI CAS CSCD 2022年第2期36-42,共7页
We report an all-fiberized chirped pulse amplification system without any bulk devices.The stretcher and compressor are chirped fiber Bragg gratings inscribed in a 6/125μm single-mode fiber and a 30/250μm largemode-... We report an all-fiberized chirped pulse amplification system without any bulk devices.The stretcher and compressor are chirped fiber Bragg gratings inscribed in a 6/125μm single-mode fiber and a 30/250μm largemode-area fiber.The fabrication system of chirped fiber Bragg gratings was designed and built by ourselves.The width of the linear exposure spot was controlled according to the different fiber sizes to improve the fabrication quality,and the parameters of chirped fiber Bragg gratings were fine-tuned during the fabrication to achieve the overall system’s spectral matching.Two fiber circulators with the same fiber sizes as the chirped fiber Bragg gratings were employed to auxiliarily achieve the pulse stretching and compression.The dispersion accumulations provided by the stretcher and compressor are 129.8 ps and 90.8 ps.The power amplifiers were composed of the two-stage 10/130μm fiber pre-amplifier and the 30/250μm fiber main amplifier.The proposed chirped pulse amplification system with no spatial light is the true sense of an all-fiberized chirped pulse amplification structure and shows the main trend in development of ultrashort pulse fiber lasers. 展开更多
关键词 FIBER AMPLIFIER COMPRESSOR
下载PDF
Short term effects of small incision lenticule extraction surgery on corneal endothelium
2
作者 Dan-Yang Wang Man-Li Liu +6 位作者 Yi-Le Chen Xiao-Ying Zhang yang-tao xu Jian-Chao Wang Chi-Ho To Jian-Guo Wang Quan Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第4期536-539,共4页
AIM: To assess the effects of small incision lenticule extraction(SMILE) surgery on the corneal endothelium at1 d to 1mo postoperatively.·METHODS: A retrospective, observational study was conducted on 47 pati... AIM: To assess the effects of small incision lenticule extraction(SMILE) surgery on the corneal endothelium at1 d to 1mo postoperatively.·METHODS: A retrospective, observational study was conducted on 47 patients(47 eyes) who received SMILE surgery. Patients were grouped according to contact lens wear condition. The corneal endothelium was examined preoperatively and at 1d, 1wk and 1mo postoperatively.The corneal endothelium was analyzed for endothelial cell density(ECD), percentage of hexagonal cells, and coefficient of variation(CV) of cell size.·RESULTS: There were no significant decrease in the ECD, percentage of hexagonal cells or increase in CV at1 d, 1wk and 1mo postoperatively(P 〉0.05). However,there was a small increase of ECD by 2.88% in contact lens wearers(78.26±113.62 cell/mm2, P 〈0.05).· CONCLUSION: SMILE has no significant adverse effects on the corneal ECD and morphology during 1mo follow-up time. 展开更多
关键词 myopia corneal endothelium refractive surgery
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部