期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Differences in the system accuracy acceptability of four types of blood glucose monitoring systems against five different standards 被引量:1
1
作者 Tengjiao Wang Lina Zhang +6 位作者 Lijun Gong yangmei xin Liang Han Na Li Peng Peng Xiuying Zhao Runqing Li 《iLABMED》 2024年第2期70-78,共9页
Objective:This study aimed to evaluate the system accuracy of four types of blood glucose monitoring systems(BGMSs)and explore the differences in the system accuracy acceptability of each BGMS against five different s... Objective:This study aimed to evaluate the system accuracy of four types of blood glucose monitoring systems(BGMSs)and explore the differences in the system accuracy acceptability of each BGMS against five different standards.Methods:The glucose measurement values obtained from four types of BGMSs(Roche Accu-Chek® Performa,Bayer Contour™ TS,Sinomedisite Glupad® H1 Plus,and Sinocare® Gold-Accu)were evaluated against the reference values obtained from the biochemical analyzer of the central laboratory.The system accuracy acceptability of each BGMS was determined using the criteria specified in five standards,namely the International Organization for Standardization(ISO)15197:2003,Clinical Laboratory Standards Institute(CLSI)POCT12-A3,ISO 15197:2013,Chinese Society of Laboratory Medicine(CSLM)consensus,and US Food and Drug Administration(FDA)guidelines.Results:From 2018 to 2022,10,980 pairs of measurement values were obtained from 366 glucose meters of four types of BGMSs.Significant correlations were observed between the glucose measurement values from the BGMSs and the reference values from the biochemical analyzer of the central laboratory.The correlation coefficient r was 0.995 for Roche Accu-Chek® Performa,0.994 for Bayer Contour™ TS,0.983 for Sinomedisite Glupad® H1 Plus,and 0.997 for SinocareR Gold-Accu.The acceptability criteria specified in ISO 15197:2003 were met by 100.00%(135/135)of the glucose meters of Roche Accu-Chek® Performa,100.00%(109/109)of Bayer Contour™ TS,81.61%(71/87)of Sinomedisite Glupad® H1 Plus,and 100.00%(35/35)of SinocareR Gold-Accu.Whereas,the acceptability criteria specified in ISO 15197:2013 were met by 99.26%(134/135)of the glucose meters of Roche Accu-Chek® Performa,88.07%(96/109)of Bayer Contour™ TS,58.62%(51/87)of Sinomedisite Glupad R H1 Plus,and 91.43%(32/35)of SinocareR Gold-Accu.Conclusions:Among the four types of BGMSs evaluated,the glucose meters of Roche Accu-Chek® Performa exhibited superior system accuracy.The system accuracy acceptability of each BGMS varied significantly against the acceptability criteria specified in the five different standards. 展开更多
关键词 blood glucose blood glucose monitoring system comparative study data accuracy
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部