Propagation and Coalescence of Blast-Induced Cracks in PMMA Material Containing an Empty Circular Hole Under Delayed Ignition Blasting Load by Using the Dynamic Caustic Method
1
作者 Zhongwen Yue Yao Song +1 位作者 Zihang Hu yanlong lu 《Journal of Beijing Institute of Technology》 EI CAS 2018年第4期547-555,共9页
In this paper,dynamic caustic method is applied to analyze the blast-induced crack propagation and distribution of the dynamic stress field around an empty circular hole in polymethyl methacrylate(PMMA)material under ... In this paper,dynamic caustic method is applied to analyze the blast-induced crack propagation and distribution of the dynamic stress field around an empty circular hole in polymethyl methacrylate(PMMA)material under delayed ignition blasting loads.The following experimental results are obtained.(1)In directional-fracture-controlled blasting,the dynamic stress intensity factors(DSIFs)and the propagation paths of the blast-induced cracks are obviously influenced by the delayed ignition.(2) The circular hole situated between the two boreholes poses a strong guiding effect on the coelesence of the cracks,causing them to propagate towards each other when cracks are reaching the circular hole area.(3)Blast-induced cracks are not initiated preferentially because of the superimposed effect from the explosive stress waves on the cracking area.(4) By using the scanning electron microscopy(SEM)method,it is verified that the roughness of crack surfaces changes along the crack propagation paths. 展开更多
关键词 crack propagation and coalescence dynamic caustic method delayed ignition blast-induced cracks dynamic stress intensity factor(DSIF)
下载PDF
A Method of Insulator’s NSDD Measurement and Its Device Based on Laser Transmission Principle
2
作者 Yang Liu Song Gao +1 位作者 Jie Chen yanlong lu 《Journal of Power and Energy Engineering》 2014年第4期518-524,共7页
Accuracy measurement of the Non-soluble Deposit Density (NSDD) on the insulator surface is very important for the transmission line anti-pollution flashover works. A method to measure the NSDD on double sheds porcelai... Accuracy measurement of the Non-soluble Deposit Density (NSDD) on the insulator surface is very important for the transmission line anti-pollution flashover works. A method to measure the NSDD on double sheds porcelain insulator surface based on laser transmission principle is proposed in this paper. Laser unit and luminous intensity sensor are installed between the up and down surface of the double sheds porcelain insulators, two glass tablets are put between the double sheds. The contamination on the glass tablets will influence the luminous intensity that reaches the intensity sensor. The luminous signal is changed to electrical signal, and the insulator’s NSDD could be obtained based on the difference of luminous intensity. The device can be used in online monitoring of the insulator's NSDD condition on the insulator surface. 展开更多
关键词 LASER Transmission NSDD LUMINOUS INTENSITY Real-Time MEASUREMENT DEVICE
下载PDF