期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
微波活化稻壳基生物质材料对亚甲基蓝的吸附性能 被引量:3
1
作者 钟倩倩 赵雅琴 +3 位作者 吴爱兵 王磊 沈丽 王鹏 《过程工程学报》 CAS CSCD 北大核心 2018年第6期1210-1218,共9页
以KOH为活化剂,采用微波活化法处理农业废稻壳,制备生物质吸附材料,通过静态吸附实验考察了其对阳离子染料亚甲基蓝的吸附性能.结果表明,所制生物质材料对亚甲基蓝的最大吸附量为109.9mg/g,吸附过程符合伪二级动力学方程和Langmuir等温... 以KOH为活化剂,采用微波活化法处理农业废稻壳,制备生物质吸附材料,通过静态吸附实验考察了其对阳离子染料亚甲基蓝的吸附性能.结果表明,所制生物质材料对亚甲基蓝的最大吸附量为109.9mg/g,吸附过程符合伪二级动力学方程和Langmuir等温吸附模式,为快速吸附和单分子层吸附,膜扩散是速率控制步骤,吸附过程为生物质材料孔道内部物理吸附和O-H官能团吸附的共同作用. 展开更多
关键词 生物质 微波活化 吸附 亚甲基蓝
原文传递
Fractionation of residual Al in natural water treatment from reservoir with poly-aluminum-silicate-chloride (PASiC): Effect of OH/Al, Si/Al molar ratios and initial pH 被引量:7
2
作者 Zhonglian Yang Baoyu Gao +2 位作者 Yan Wang yaqin zhao Qinyan Yue 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第11期1908-1916,共9页
An aluminum fractionation study was conducted for a surface reservoir water treatment to understand the performance of poly- aluminum-silicate-chloride (PASiC) in terms of the residual A1 fractions as a function of ... An aluminum fractionation study was conducted for a surface reservoir water treatment to understand the performance of poly- aluminum-silicate-chloride (PASiC) in terms of the residual A1 fractions as a function of initial pH. The coagulation performance expressed as turbidity and organic matter removal was established as supporting data. Some extra data were evaluated in terms of the residual A1 ratio of the composite PASiC coagulant. The main residual A1 sources were the A1 fractions derived from the use of PASiC. The turbidity and organic matter removal ability was optimal at initial pH 6.00-7.00, while the concentrations of various residual A1 species and the residual A1 ratio of PASiC were minimal at an initial pH range of 7.00-8.00. Under the conditions of OH/AI molar ratio = 2.00 and Si/A1 molar ratio = 0.05, PASiC had superior coagulation performance and comparatively low residual A1 concentrations. The A1 fraction in the composite PASiC coagulant seldom remained under such conditions. Experimental data also indicated that the suspended (filterable) AI fraction was the dominant species, and organic-bound or organo-A1 complex A1 was considered to be the major species of dissolved A1 in water treated by PASiC coagulation. Additionally, the dissolved inorganic monomeric A1 species dominated the dissolved monomeric A1 fraction. 展开更多
关键词 coagulation performance OH/A1 and Si/AI molar ratio poly-aluminum-silicate-chloride (PAniC) resi0ual AI speclataon residual A1 ratio
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部