Safe and efficient operation of batteries is always desired but batteries with a high energy density pose a threat to the system causing thermal breakdown,reduced performance and rapid ageing.To reduce such vulnerabil...Safe and efficient operation of batteries is always desired but batteries with a high energy density pose a threat to the system causing thermal breakdown,reduced performance and rapid ageing.To reduce such vulnerabilities,an optimum environment with controlled parameters is required.Four parameters have been considered for analysis,i.e.state of charge,current,voltage and temperature.The module makes a detailed analysis of the above-mentioned parameters and suggests a microcontroller-based prototype that is capable of monitoring the external factors in real time and generating relevant warnings.展开更多
文摘Safe and efficient operation of batteries is always desired but batteries with a high energy density pose a threat to the system causing thermal breakdown,reduced performance and rapid ageing.To reduce such vulnerabilities,an optimum environment with controlled parameters is required.Four parameters have been considered for analysis,i.e.state of charge,current,voltage and temperature.The module makes a detailed analysis of the above-mentioned parameters and suggests a microcontroller-based prototype that is capable of monitoring the external factors in real time and generating relevant warnings.