Improvement of Cardiac Function by Dry Weight Optimization Based on Interdialysis Inferior Vena Caval Diameter(2) 被引量:2
1
作者 Shixue Hirayama Yasuhiro Ando +1 位作者 Yuji Sud yasushi asano 《中国血液净化》 2002年第12期1-3,共3页
关键词 CTR DBP SBP EF Improvement of Cardiac Function by Dry Weight Optimization Based on Interdialysis Inferior Vena Caval Diameter
下载PDF
Improvement of Cardiac Function by Dry Weight Optimization Based on Interdialysis Inferior Vena Caval Diameter (1) 被引量:1
2
作者 Shizue Hirayama Yasuhiro Ando +1 位作者 Yuji Sudo yasushi asano 《中国血液净化》 2002年第11期1-2,共2页
In hemodialysis (HD) patients, the diameter of the inferior vena cava (IVC) serves for evaluation of the amount of body fluid.
关键词 In Improvement of Cardiac Function by Dry Weight Optimization Based on Interdialysis Inferior Vena Caval Diameter BODY IVC
下载PDF
The Inferior Vena Cava Diameter as a Marker of Dry Weight in Chronic Hemodialyzed Patients
3
作者 Yasuhiro Ando Satoru Yanagiba yasushi asano 《中国血液净化》 2002年第9期3-4,共2页
We have previously reported that the diameter of the inferior vena cava(IVC) reflects the amount of body fluid in hemodialyzed (HD) patients. The present study was undertaken to depict the criteria of IVC diameters fo... We have previously reported that the diameter of the inferior vena cava(IVC) reflects the amount of body fluid in hemodialyzed (HD) patients. The present study was undertaken to depict the criteria of IVC diameters for determining dry weight (DW) in anuric HD patients. In healthy subjects, the maximal diameters during quiet expiration (IVCe) and the minimal diameters during quiet inspiration (IVCi) were (16.7±3.2) and (5.7±5.4)mm,respectively (mean±SD).The collapsibility index (CI,1-IVCi/IVCe), which inversely correlates with the central venous pressure,was 0.68±0.29. In anuric HD patients,the IVCe/CI values before and after HD were 14.9±3.2/0.68±0.24 and 8.2±2.3/0.94±0.09, respectively. IVCe decreased proportionally to the amount of ultrafiltration. In HD patients with hypervolemic pulmonary edema, the IVCe and CI values were 22.4±2.9 and 0.22±0.11, respectively. We proposed that IVCe/CI after HD is (8±3)mm/0.9 ± 0.1 as the markers of DW in anuric HD patients and that an IVCe value≥22mm together with a CI≤0.22 implies the warning level of body fluid retention. 展开更多
关键词 HEMODIALYSIS ULTRASONOGRAPHY Inferior vena cava Dry weight Body fluid volume.
下载PDF
Improvement of Cardiac Function by Dry Weight Optimization Based on Interdialysis Inferior Vena Caval Diameter(3)
4
作者 Shixue HIRAYAMA Yasuhiro ANDO +1 位作者 Yuji SUDO yasushi asano 《中国血液净化》 2003年第1期2-4,34,共4页
The nonimprovement group was characterized by the following: ① a high incidence of diabetes (4 of 6 patients) ,② a high incidence of preexisting cardiac dysfunction documented prior to or at the time of induction
关键词 心功能 血液净化 干重量
下载PDF
The Inferior Vena Cava Diameter as a Marker of Dry Weight in Chronic Hemodialyzed Patients(续)
5
作者 Yasuhiro Ando Satoru Yanagiba yasushi asano 《中国血液净化》 2002年第10期1-4,共4页
  The IVC diameters in HD patients   Since BW and stature as well as gender and age were not considered to be determinant factors of the IVC diameters, these factors were not accounted for in evaluating the IVC d...   The IVC diameters in HD patients   Since BW and stature as well as gender and age were not considered to be determinant factors of the IVC diameters, these factors were not accounted for in evaluating the IVC diameters in HD patients. The IVC diameters of stable anuric HD patients are shown in Table 2. In agreement with our previous observation [7-9] ,the reduction of BW from (51.7±12.6) to (49.3±12.6)kg by ultrafiltration during HD resulted in a significant (P<0.0001)reduction of the IVCe and IVCi from (14.9 ± 3.2) to (6.8±1.9)mm and (5.2±4.2) to (0.1±0.3) mm,respectively. Thus,CI values before and at the end of HD were calculated as (0.68±0.24) and (0.98±0. 05), respectively (P<0.0001).   …… 展开更多
关键词 IVC The Inferior Vena Cava Diameter as a Marker of Dry Weight in Chronic Hemodialyzed Patients
下载PDF