期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The High Energy X-ray telescope (HE) onboard the Insight-HXMT astronomy satellite 被引量:9
1
作者 CongZhan Liu YiFei Zhang +30 位作者 XuFang Li XueFeng Lu Zhi Chang ZhengWei Li AiMei Zhang YongJie Jin HuiMing Yu Zhao Zhang MinXue Fu YiBao Chen JianFeng Ji YuPeng Xu JingKang Deng RenCheng Shang GuoQing Liu FangJun Lu ShuangNan Zhang YongWei Dong TiPei Li Mei Wu yanguo Li HuanYu Wang BoBing Wu YongJie Zhang Zhi Zhang ShaoLin Xiong Yuan Liu Shu Zhang HongWei Liu yijung yang Fan Zhang 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2020年第4期20-34,共15页
The Insight-Hard X-ray Modulation Telescope(Insight-HXMT) is a broadband X-ray and γ-ray(1-3000 ke V) astronomy satellite. One of its three main telescopes is the High Energy X-ray telescope(HE). The main detector pl... The Insight-Hard X-ray Modulation Telescope(Insight-HXMT) is a broadband X-ray and γ-ray(1-3000 ke V) astronomy satellite. One of its three main telescopes is the High Energy X-ray telescope(HE). The main detector plane of HE comprises 18 Na I(Tl)/Cs I(Na) phoswich detectors, where Na I(Tl) is used as the primary detector to measure ~ 20-250 ke V photons incident from the field of view(FOV) defined by collimators, and Cs I(Na) is used as the active shielding detector to Na I(Tl) by pulse shape discrimination. Additionally, Cs I(Na) is used as an omnidirectional γ-ray monitor. The HE collimators have a diverse FOV,i.e. 1.1°×5.7°(15 units), 5.7°×5.7°(2 units), and blocked(1 unit). Therefore, the combined FOV of HE is approximately5.7°×5.7°. Each HE detector has a diameter of 190 mm resulting in a total geometrical area of approximately 5100 cm2, and the energy resolution is ~15% at 60 ke V. For each recorded X-ray event by HE, the timing accuracy is less than 10 μs and the deadtime is less than 10 μs. HE is used for observing spectra and temporal variability of X-ray sources in the 20-250 ke V band either by pointing observations for known sources or scanning observations to unveil new sources. Additionally, HE is used for monitoring the γ-ray burst in 0.2-3 Me V band. This paper not only presents the design and performance of HE instruments but also reports results of the on-ground calibration experiments. 展开更多
关键词 X-RAY TELESCOPE HXMT calibration scintillation DETECTOR
原文传递
The Low Energy X-ray telescope (LE) onboard the Insight-HXMT astronomy satellite 被引量:8
2
作者 Yong Chen WeiWei Cui +24 位作者 Wei Li Juan Wang YuPeng Xu FangJun Lul YuSa Wang TianXiang Chen DaWei Han Wei Hu Yi Zhang Jia Huo YanJi yang MaoShun Li Bo Lu ZiLiang Zhang TiPei Li ShuangNan Zhang ShaoLin Xiong Shu Zhang RongFeng Xue XiaoFan Zhao Yue Zhu YuXuan Zhu HongWei Liu yijung yang Fan Zhang 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2020年第4期49-61,共13页
The Low Energy X-ray telescope(LE) is one of the three main instruments of the Insight-Hard X-ray Modulation Telescope(Insight-HXMT). It is equipped with Swept Charge Device(SCD) sensor arrays with a total geometrical... The Low Energy X-ray telescope(LE) is one of the three main instruments of the Insight-Hard X-ray Modulation Telescope(Insight-HXMT). It is equipped with Swept Charge Device(SCD) sensor arrays with a total geometrical area of 384 cm^2 and an energy band from 0.7 to 13 ke V. In order to evaluate the particle induced X-ray background and the cosmic X-ray background simultaneously, LE adopts collimators to define four types of Field Of Views(FOVs), i.e., 1.6°×6°, 4°×6°, 50°-60°×2°-6 oand the blocked ones which block the X-ray by an aluminum cover. LE is constituted of three detector boxes(LEDs) and an electric control box(LEB) and achieves a good energy resolution of 140 e V@5.9 ke V, an excellent time resolution of 0.98 ms, as well as an extremely low pileup(<1%@18000 cts/s). Detailed performance tests and calibration on the ground have been performed,including energy-channel relation, energy response, detection efficiency and time response. 展开更多
关键词 LE X-ray telescope SCD COLLIMATORS
原文传递
The Medium Energy X-ray telescope (ME) onboard the Insight-HXMT astronomy satellite 被引量:5
3
作者 XueLei Cao WeiChun Jiang +38 位作者 Bin Meng WanChang Zhang Tao Luo Sheng yang ChunLei Zhang YuDong Gu Liang Sun XiaoJing Liu JiaWei yang Xian Li Ying Tan ShaoZhen Liu YuanYuan Du FangJun Lu YuPeng Xu Ju Guan ShuangNan Zhang HuanYu Wang TiPei Li ChengMo Zhang Xiangyang Wen JinLu Qu LiMing Song XiaoBo Li MingYu Ge YuPeng Zhou ShaoLin Xiong Shu Zhang YongJie Zhang ZeHao Cheng Fei Zhang MaoShun Li XiaoHua Liang Min Gao EnBo yang XiaoHang Liu HongWei Liu yijung yang Fan Zhang 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2020年第4期35-48,共14页
The Medium Energy X-ray telescope(ME) is one of the three main telescopes on board the Insight hard X-ray modulation telescope(Insight-HXMT) astronomy satellite. ME contains 1728 pixels of Si-PIN detectors sensitive i... The Medium Energy X-ray telescope(ME) is one of the three main telescopes on board the Insight hard X-ray modulation telescope(Insight-HXMT) astronomy satellite. ME contains 1728 pixels of Si-PIN detectors sensitive in 5-30 ke V with a total geometrical area of 952 cm^2. The application specific integrated circuit(ASIC) chip, VA32TA6, is used to achieve low power consumption and low readout noise. The collimators define three kinds of field of views(FOVs) for the telescope, 1°×4°, 4°×4°,and blocked ones. Combination of such FOVs can be used to estimate the in-orbit X-ray and particle background components.The energy resolution of ME is ~3 ke V at 17.8 ke V(FWHM) and the time resolution is 255 μs. In this paper, we introduce the design and performance of ME. 展开更多
关键词 Si-PIN ASIC MEDIUM ENERGY X-RAY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部