The operating range of the flow rate or flow velocity for the micro-jet flame is quite wide,which can be used as the heat source.In order to optimize the micro-jet tube combustor in terms of the solid material,the pre...The operating range of the flow rate or flow velocity for the micro-jet flame is quite wide,which can be used as the heat source.In order to optimize the micro-jet tube combustor in terms of the solid material,the present paper numerically investigates the impact of thermal conductivity(λs)on the operating limit of micro-jet flame.Unexpectedly,the non-monotonic blow-off limits with the increase ofλs is found,and the corresponding generation mechanisms are analyzed in terms of the thermal coupling effect,flow field,and strain effect.At first,the lower preheating temperature of the fuel and larger heat loss amount to the environment lead to a larger blow-off limit at a largerλs.After that,the smaller local flow velocity in the vicinity of flame root and smaller strain effect slightly increase the blow-off limit with the continuously increasingλs.Therefore,it is deduced that the applied performance of micro-jet combustor with a smaller thermal conductivity is better in terms of the blow-off limit.展开更多
Adult polyglucosan body disease(APBD)is a rare and highly heterogeneous glycogen storage disorder due to biallelic variants in GBE1.1 Typical APBD presentations include gait abnormalities with polyneuropathy,leukodyst...Adult polyglucosan body disease(APBD)is a rare and highly heterogeneous glycogen storage disorder due to biallelic variants in GBE1.1 Typical APBD presentations include gait abnormalities with polyneuropathy,leukodystrophy,neurogenic bladder,and mild cognitive impairment.Differential diagnosis of APBD encompasses a large spectrum of conditions including axonal and demyelinating sensorimotor polyneuropathy,progressive spastic paraparesis,and leukodystrophies.展开更多
文摘The operating range of the flow rate or flow velocity for the micro-jet flame is quite wide,which can be used as the heat source.In order to optimize the micro-jet tube combustor in terms of the solid material,the present paper numerically investigates the impact of thermal conductivity(λs)on the operating limit of micro-jet flame.Unexpectedly,the non-monotonic blow-off limits with the increase ofλs is found,and the corresponding generation mechanisms are analyzed in terms of the thermal coupling effect,flow field,and strain effect.At first,the lower preheating temperature of the fuel and larger heat loss amount to the environment lead to a larger blow-off limit at a largerλs.After that,the smaller local flow velocity in the vicinity of flame root and smaller strain effect slightly increase the blow-off limit with the continuously increasingλs.Therefore,it is deduced that the applied performance of micro-jet combustor with a smaller thermal conductivity is better in terms of the blow-off limit.
基金the National Natural Science Foundation of China(No.82271412 to J.H.,82025012 to W.J.C.,U1905210 to W.J.C.).
文摘Adult polyglucosan body disease(APBD)is a rare and highly heterogeneous glycogen storage disorder due to biallelic variants in GBE1.1 Typical APBD presentations include gait abnormalities with polyneuropathy,leukodystrophy,neurogenic bladder,and mild cognitive impairment.Differential diagnosis of APBD encompasses a large spectrum of conditions including axonal and demyelinating sensorimotor polyneuropathy,progressive spastic paraparesis,and leukodystrophies.