期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Predictions of nuclear charge radii based on the convolutional neural network
1
作者 ying-yu cao Jian-You Guo Bo Zhou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期83-90,共8页
In this study, we developed a neural network that incorporates a fully connected layer with a convolutional layer to predict the nuclear charge radii based on the relationships between four local nuclear charge radii.... In this study, we developed a neural network that incorporates a fully connected layer with a convolutional layer to predict the nuclear charge radii based on the relationships between four local nuclear charge radii. The convolutional neural network(CNN) combines the isospin and pairing effects to describe the charge radii of nuclei with A ≥ 39 and Z ≥ 20. The developed neural network achieved a root mean square(RMS) deviation of 0.0195 fm for a dataset with 928 nuclei. Specifically, the CNN reproduced the trend of the inverted parabolic behavior and odd–even staggering observed in the calcium isotopic chain, demonstrating reliable predictive capability. 展开更多
关键词 Nuclear charge radii Machine learning Neural network
下载PDF
Composite Configuration Interventional Therapy Robot for the Microwave Ablation of Liver Tumors 被引量:4
2
作者 ying-yu cao Long Xue +4 位作者 Bo-Jin Qi Li-Pei Jiang Shuang-Cheng Deng Ping Liang Jia Liu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第6期1416-1425,共10页
The existing interventional therapy robots for the microwave ablation of liver tumors have a poor clinical applicability with a large volume, low positioning speed and complex automatic navigation control. To solve ab... The existing interventional therapy robots for the microwave ablation of liver tumors have a poor clinical applicability with a large volume, low positioning speed and complex automatic navigation control. To solve above problems, a composite configuration interventional therapy robot with passive and active joints is developed. The design of composite configuration reduces the size of the robot under the premise of a wide range of movement, and the robot with composite configuration can realizes rapid positioning with operation safety. The cumulative error of positioning is eliminated and the control complexity is reduced by decoupling active parts. The navigation algo- rithms for the robot are proposed based on solution of the inverse kinematics and geometric analysis. A simulation clinical test method is designed for the robot, and the functions of the robot and the navigation algorithms are verified by the test method. The mean error of navigation is 1.488 mm and the maximum error is 2.056 mm, and thepositioning time for the ablation needle is in 10 s. The experimental results show that the designed robot can meet the clinical requirements for the microwave ablation of liver tumors. The composite configuration is proposed in development of the interventional therapy robot for the microwave ablation of liver tumors, which provides a new idea for the structural design of medical robots. 展开更多
关键词 ROBOT Composite configuration Interventional therapy Decoupling mechanismIntelligent positioning Composite configuration
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部