Accurate modeling and parameters of high voltage (HV) grid are critical for stability research of system frequency. In this paper, simulation modeling of the system frequency was conducted of an interconnected power...Accurate modeling and parameters of high voltage (HV) grid are critical for stability research of system frequency. In this paper, simulation modeling of the system frequency was conducted of an interconnected power system with HV transmission lines in China. Based on recorded tripping data of the HV transmission lines, system parameters were identified by using genetic algorithm (GA). The favorable agreement between simulation results and recorded data verifies the validity of gird models and the accuracy of system parameters. The results of this paper can provide reference for the stability research of HV power grid.展开更多
The increasing capacity of nuclear units in power grid poses threat to system stability and security. Load disturbance may cause overspeed of the units and trigger the overspeed protection controller (OPC). Repeat- ...The increasing capacity of nuclear units in power grid poses threat to system stability and security. Load disturbance may cause overspeed of the units and trigger the overspeed protection controller (OPC). Repeat- ing actions of valves have a strong impact on the security of the equipment and may result in a collapse of the power system. Based on the analysis of frequency regulation, mathematic models for nuclear units in the grid are established in this paper to simulate the dynamic process when load disturbance occurs. The critical action of the OPC is proposed as the constraint of safe operation for the units. The relationship between different styles of frequency regulation and the allowable capacity of the nuclear units in the grid is discussed. This research can help to estimate the capacity limitation of nuclear units in the grid.展开更多
文摘Accurate modeling and parameters of high voltage (HV) grid are critical for stability research of system frequency. In this paper, simulation modeling of the system frequency was conducted of an interconnected power system with HV transmission lines in China. Based on recorded tripping data of the HV transmission lines, system parameters were identified by using genetic algorithm (GA). The favorable agreement between simulation results and recorded data verifies the validity of gird models and the accuracy of system parameters. The results of this paper can provide reference for the stability research of HV power grid.
文摘The increasing capacity of nuclear units in power grid poses threat to system stability and security. Load disturbance may cause overspeed of the units and trigger the overspeed protection controller (OPC). Repeat- ing actions of valves have a strong impact on the security of the equipment and may result in a collapse of the power system. Based on the analysis of frequency regulation, mathematic models for nuclear units in the grid are established in this paper to simulate the dynamic process when load disturbance occurs. The critical action of the OPC is proposed as the constraint of safe operation for the units. The relationship between different styles of frequency regulation and the allowable capacity of the nuclear units in the grid is discussed. This research can help to estimate the capacity limitation of nuclear units in the grid.