Simulation of performance of intermediate fluid vaporizer under wide operation conditions
1
作者 Bojie WANG Wen WANG +2 位作者 Chao QI yiwu kuang Jiawei XU 《Frontiers in Energy》 SCIE CSCD 2020年第3期452-462,共11页
The intermediate fluid vaporizer(IFV)is a typical vaporizer of liquefied natural gas(LNG),which in general consists of three shell-and-tube heat exchangers(an evaporator,a condenser,and a thermolator).LNG is heated by... The intermediate fluid vaporizer(IFV)is a typical vaporizer of liquefied natural gas(LNG),which in general consists of three shell-and-tube heat exchangers(an evaporator,a condenser,and a thermolator).LNG is heated by seawater and the intermediate fluid in these heat exchangers.A one-dimensional heat transfer model for IFV is established in this paper in order to investigate the influences of structure and operation parameters on the heat transfer performance.In the rated condition,it is suggested to reduce tube diameters appropriately to get a large total heat transfer coefficient and increase the tube number to ensure the sufficient heat transfer area.According to simulation results,although the IFV capacity is much larger than the simplified-IFV(SIFV)capacity,the mode of SIFV could be recommended in some low-load cases as well.In some cases at high loads exceeding the capacity of a single IFV,it is better to add an AAV or an SCV operating to the IFV than just to increase the mass flow rate of seawater in the IFV in LNG receiving terminals. 展开更多
关键词 liquefied natural gas intermediate fluid vaporizer heat transfer performance numerical simulation extreme condition