The spin-polarized photocurrent is used to study the in-plane electric field dependent spin transport in undoped InGaAs/AlGaAs multiple quantum wells. In the temperature range of 77–297 K, the spin-polarized photocur...The spin-polarized photocurrent is used to study the in-plane electric field dependent spin transport in undoped InGaAs/AlGaAs multiple quantum wells. In the temperature range of 77–297 K, the spin-polarized photocurrent shows an anisotropic spin transport under different oriented in-plane electric fields. We ascribe this characteristic to two dominant mechanisms: the hot phonon effect and the Rashba spin-orbit effect which is influenced by the in-plane electric fields with different orientations. The formulas are proposed to fit our experiments, suggesting a guide of potential applications and devices.展开更多
BACKGROUND Anastomosis of the testicular vein with the superior mesenteric vein rarely causes severe gastrointestinal bleeding.To date,there have been few studies describing its appearance on medical imaging.Here,we p...BACKGROUND Anastomosis of the testicular vein with the superior mesenteric vein rarely causes severe gastrointestinal bleeding.To date,there have been few studies describing its appearance on medical imaging.Here,we present multidetector computed tomography three-dimensional and multiplanar reconstruction(MPR)images of a typical digital subtraction angiography showing proven ectopic bleeding and provide the first review of the image performance.CASE SUMMARY A 68-year-old man who had been rushed to the hospital with a four-day history of melena and fainting underwent multiple esophagogastroduodenoscopy procedures that failed to identify the source of bleeding.We used MPR combined with three-dimensional reconstruction images,and found that the testicular vein had anastomosed with the superior mesenteric vein,and they clustered together in the jejunal vessel wall,which caused severe gastrointestinal bleeding.Digital subtraction angiography confirmed the location of bleeding.After transfusion and embolization therapy,the patient’s condition improved.CONCLUSION Computed tomography-MPR combined with three-dimensional images offers significant value in the localization and qualitative assessment of rare gastrointestinal hemorrhage.The features of multiphase spiral scanning can improve the accuracy of the diagnosis.展开更多
基金Supported by the National Basic Research Program of China under Grant No 2015CB921503the National Natural Science Foundation of China under Grant Nos 61474114,11574302,61627822 and 11704032the National Key Research and Development Program of China under Grant Nos 2018YFA0209103,2016YFB0402303 and 2016YFB0400101
文摘The spin-polarized photocurrent is used to study the in-plane electric field dependent spin transport in undoped InGaAs/AlGaAs multiple quantum wells. In the temperature range of 77–297 K, the spin-polarized photocurrent shows an anisotropic spin transport under different oriented in-plane electric fields. We ascribe this characteristic to two dominant mechanisms: the hot phonon effect and the Rashba spin-orbit effect which is influenced by the in-plane electric fields with different orientations. The formulas are proposed to fit our experiments, suggesting a guide of potential applications and devices.
文摘BACKGROUND Anastomosis of the testicular vein with the superior mesenteric vein rarely causes severe gastrointestinal bleeding.To date,there have been few studies describing its appearance on medical imaging.Here,we present multidetector computed tomography three-dimensional and multiplanar reconstruction(MPR)images of a typical digital subtraction angiography showing proven ectopic bleeding and provide the first review of the image performance.CASE SUMMARY A 68-year-old man who had been rushed to the hospital with a four-day history of melena and fainting underwent multiple esophagogastroduodenoscopy procedures that failed to identify the source of bleeding.We used MPR combined with three-dimensional reconstruction images,and found that the testicular vein had anastomosed with the superior mesenteric vein,and they clustered together in the jejunal vessel wall,which caused severe gastrointestinal bleeding.Digital subtraction angiography confirmed the location of bleeding.After transfusion and embolization therapy,the patient’s condition improved.CONCLUSION Computed tomography-MPR combined with three-dimensional images offers significant value in the localization and qualitative assessment of rare gastrointestinal hemorrhage.The features of multiphase spiral scanning can improve the accuracy of the diagnosis.