期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
1
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
下载PDF
Development of vacuum ultraviolet spectroscopy for measuring edge impurity emission in the EAST tokamak 被引量:4
2
作者 Hongming ZHANG Bo LYU +9 位作者 Liang HE yongcai shen Jun CHEN Jia FU Bin BIN Xunyu WANG Fudi WANG Yingying LI Ling ZHANG Bing LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第8期8-13,共6页
The dominant wavelength range of edge impurity emissions moves from the visible range to the vacuum ultraviolet(VUV)range,as heating power increasing in the Experimental Advanced Superconducting Tokamak(EAST).The meas... The dominant wavelength range of edge impurity emissions moves from the visible range to the vacuum ultraviolet(VUV)range,as heating power increasing in the Experimental Advanced Superconducting Tokamak(EAST).The measurement provided by the existing visible spectroscopies in EAST is not sufficient for impurity transport studies for high-parameters plasmas.Therefore,in this study,a VUV spectroscopy is newly developed to measure edge impurity emissions in EAST.One Seya-Namioka VUV spectrometer(McPherson 234/302)is used in the system,equipped with a concave-corrected holographic grating with groove density of 600 grooves mm-1.Impurity line emissions can be observed in the wavelength range ofλ=50-700 nm,covering VUV,near ultraviolet and visible ranges.The observed vertical range is Z=-350-350 mm.The minimum sampling time can be set to 5 ms under full vertical binning(FVB)mode.VUV spectroscopy has been used to measure the edge impurity emission for the 2019 EAST experimental campaign.Impurity spectra are identified for several impurity species,i.e.,lithium(Li),carbon(C),oxygen(O),and iron(Fe).Several candidates for tungsten(W)lines are also measured but their clear identification is very difficult due to a strong overlap with Fe lines.Time evolutions of impurity carbon emissions of CⅡat 134.5 nm and CⅢat 97.7 nm are analyzed to prove the system capability of time-resolved measurement.The measurements of the VUV spectroscopy are very helpful for edge impurity transport study in the high-parameters plasma in EAST. 展开更多
关键词 EAST TOKAMAK IMPURITY tungsten vacuum ULTRAVIOLET SPECTROSCOPY EDGE IMPURITY EMISSION plasma diagnostics
下载PDF
Measurement of molybdenum ion density for L-mode and H-mode plasma discharges in the EAST tokamak 被引量:3
3
作者 yongcai shen Hongming Zhang +8 位作者 Bo Lyu Yingying Li Jia Fu Fudi Wang Qing Zang Baonian Wan Pan Pan Minyou Ye 不详 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第6期333-338,共6页
We report the measurement of total molybdenum ion density for L-mode and H-mode plasmas on EAST using spectral lines observation and calculation based on an impurity transport code.A flat-filed extreme ultraviolet spe... We report the measurement of total molybdenum ion density for L-mode and H-mode plasmas on EAST using spectral lines observation and calculation based on an impurity transport code.A flat-filed extreme ultraviolet spectrometer with some spatial resolution is used to obtain the radial profiles of molybdenum spectral line emissions.The absolute calibration for the extreme ultraviolet spectrometer is finished by comparing the calculated bremsstrahlung intensity with the readings of CCD detector.Molybdenum ion transport study is performed using the radial ion density profiles and one-dimensional impurity transport code STRAHL.The total molybdenum density profiles are determined from the transport analysis.The molybdenum density during L-mode and H-mode phases are obtained,which are about 3 and 4 orders of magnitude smaller than the electron density,respectively.An inward pinch is found during the H-mode phase that leads to the peaked profile of molybdenum density. 展开更多
关键词 EAST EUV spectroscopy molybdenum density L-mode and H-mode
下载PDF
Space-resolved vacuum-ultraviolet spectroscopy for measuring impurity emission from divertor region of EAST tokamak 被引量:2
4
作者 Liang HE yongcai shen +13 位作者 Hongming ZHANG Bo LYU Cheonho BAE Huajian JI Chaoyang LI Jia FU Xuewei DU Fudi WANG Qiuping WANG Xianghui YIN Shunkuan WAN Bin BIN Yichao LI Shuyu DAI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第6期14-22,共9页
The measurement of impurity distribution in the divertor region of tokamaks is key to studying edge impurity transport.Therefore,a space-resolved vacuum-ultraviolet(VUV)spectrometer is designed to measure impurity emi... The measurement of impurity distribution in the divertor region of tokamaks is key to studying edge impurity transport.Therefore,a space-resolved vacuum-ultraviolet(VUV)spectrometer is designed to measure impurity emission in the divertor region on EAST.For good spectral resolution,an eagle-type VUV spectrometer with 1 m long focal length with spherical holograph grating is used in the system.For light collection,a collimating mirror is installed between the EAST plasma and the VUV spectrometer to extend the observing range to cover the upper divertor region.Two types of detectors,i.e.a back-illuminated charge-coupled device detector and a photomultiplier-tube detector,are adopted for the spectral measurement and high-frequency intensity measurement for feedback control,respectively.The angle between the entrance and exit optical axis is fixed at 15°.The detector can be moved along the exit axis to maintain a good focusing position when the wavelength is scanned by rotating the grating.The profile of impurity emissions is projected through the space-resolved slit,which is set horizontally.The spectrometer is equipped with two gratings with 2400 grooves/mm and2160 grooves/mm,respectively.The overall aberration of the system is reduced by accurate detector positioning.As a result,the total spectral broadening can be reduced to about 0.013 nm.The simulated performance of the system is found to satisfy the requirement of measurement of impurity emissions from the divertor area of the EAST tokamak. 展开更多
关键词 impurity measurement vacuum-ultraviolet spectrometer EAST divertor
下载PDF
Observation and characterization of the effect of electron cyclotron waves on toroidal rotation in EAST L-mode discharges 被引量:2
5
作者 Jun CHEN Ruiji HU +17 位作者 Bo LYU Fudi WANG Xiaojie WANG Handong XU Yingying LI Jia FU Xianghui YIN Dajun WU Fukun LIU Qing ZANG Haiqing LIU Yuejiang SHI Shifeng MAO Yi YU Baonian WAN Minyou YE yongcai shen EAST team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第10期14-19,共6页
The change in the toroidal rotation of plasma caused by electron cyclotron wave(ECW) injection has been observed in EAST. It is found that the response of the rotation is similar for all possible ECW toroidal inject... The change in the toroidal rotation of plasma caused by electron cyclotron wave(ECW) injection has been observed in EAST. It is found that the response of the rotation is similar for all possible ECW toroidal injection angles. The core toroidal rotation velocity increases in the co-current direction along with a rise in the plasma temperature and stored energy. The profile of the electron temperature, ion temperature and toroidal rotation velocity gradually become peaked.The change in toroidal rotation in the core increases with the ECW injection power. Different behavior is observed when the ECWs are injected into low hybrid current drive(LHCD) target plasmas, where the electron temperature and rotation profile become peaked, while the ion temperature profile flattens after ECW injection, suggesting different transport characteristics in energy and momentum. 展开更多
关键词 ECW plasma toroidal rotation LHCD x-ray crystal spectrometer
下载PDF
Measurement of impurity lines with two-crystal x-ray spectrometers on EAST
6
作者 Xinshuai YANG Ruiji HU +7 位作者 Jun CHEN Fudi WANG Jia FU Yingying LI Hongming ZHANG yongcai shen Xianghui YIN Bo LYU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第12期1-8,共8页
To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate cry... To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate crystals with similar Bragg angles, plasma temperature in the range of 0.5 keV≤Te≤10 keV and rotation can be diagnosed based on the He-like and H-like argon spectra. However, due to the added complexity in the two-crystal assembly in which the spectra might be diffracted by two crystals, some additional impurity lines were identified. For example,tungsten(W) lines in different ionization states were diffracted by the He-like and H-like crystal.Additional molybdenum(Mo) lines in the wavelength range of He-like and H-like argon spectra lines were also summarized. The existence of these additional lines caused the fitted temperature to be different from the true values. This paper presents the identified lines through a comparison with available database, which should be included in the fitting procedure. 展开更多
关键词 plasma diagnostics x-ray two-crystal spectrometer Doppler broadening dielectronicsatellite
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部