A new multi-channel motional Stark effect(MSE)diagnostic system has been developed on the upgraded EAST tokamak,which was installed on the port C to observe a tangential neutral beam.A telecentric imaging lens was dep...A new multi-channel motional Stark effect(MSE)diagnostic system has been developed on the upgraded EAST tokamak,which was installed on the port C to observe a tangential neutral beam.A telecentric imaging lens was deployed to ensure uniform illumination from the core to the boundary.A square fiber head which contained 23 fiber bundles was mounted to this imaging lens;each fiber bundle contained 19 fibers and two of them were assigned to CXRS and BES spectrometer,respectively.The angle tuning method was used for matching the Doppler shift of theσcomponent’s wavelength which was caused by the beam voltage.At the present stage,the MSE system only contains ten channels that would be extended to 23 channels in the future,covering a measurement range from R=1.8 to R=2.27 m with a temporal resolution of 10 ms and a spatial resolution of3 cm.The polarization angle-constrained q profiles and current density profiles were reconstructed with EFIT equilibrium reconstructions.In the sawtooth discharges,the q=1 surface position was validated by the ECE signals,which further verified the rationality of the MSE measurement.展开更多
The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-to...The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved.展开更多
A pilot single-channel Motional Stark Effect(MSE) diagnostic has been developed on EAST since 2015. The dual photo-elastic modulators(PEM) were employed to encode the polarization angle into a time-varying signal....A pilot single-channel Motional Stark Effect(MSE) diagnostic has been developed on EAST since 2015. The dual photo-elastic modulators(PEM) were employed to encode the polarization angle into a time-varying signal. The pitch angle was related to the ratio of modulation amplitude at the second harmonic frequency. A digital harmonic analyzer(DHA) technique was developed for extracting the second harmonic amplitude. The results were validated with a hardware phase lock-in amplifier, and is also consistent with the software dual phase-locking algorithm.展开更多
基金supported by the National MCF Energy R&D Program of China(No.2019YFE03040000)National Natural Science Foundation of China(Nos.12075280 and 11805236)+2 种基金Anhui Provincial Natural Science Foundation(No.1908085J01)CAS President’s International Fellowship Initiative(No.2022VMB0007)Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228)。
文摘A new multi-channel motional Stark effect(MSE)diagnostic system has been developed on the upgraded EAST tokamak,which was installed on the port C to observe a tangential neutral beam.A telecentric imaging lens was deployed to ensure uniform illumination from the core to the boundary.A square fiber head which contained 23 fiber bundles was mounted to this imaging lens;each fiber bundle contained 19 fibers and two of them were assigned to CXRS and BES spectrometer,respectively.The angle tuning method was used for matching the Doppler shift of theσcomponent’s wavelength which was caused by the beam voltage.At the present stage,the MSE system only contains ten channels that would be extended to 23 channels in the future,covering a measurement range from R=1.8 to R=2.27 m with a temporal resolution of 10 ms and a spatial resolution of3 cm.The polarization angle-constrained q profiles and current density profiles were reconstructed with EFIT equilibrium reconstructions.In the sawtooth discharges,the q=1 surface position was validated by the ECE signals,which further verified the rationality of the MSE measurement.
文摘The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved.
基金supported by the National Magnetic Confinement Fusion Science Program of China under Contract Nos. 2013GB112004 and 2015GB103003National Natural Science Foundation of China under Grant Nos. 11605242, 11535013 and 11405212
文摘A pilot single-channel Motional Stark Effect(MSE) diagnostic has been developed on EAST since 2015. The dual photo-elastic modulators(PEM) were employed to encode the polarization angle into a time-varying signal. The pitch angle was related to the ratio of modulation amplitude at the second harmonic frequency. A digital harmonic analyzer(DHA) technique was developed for extracting the second harmonic amplitude. The results were validated with a hardware phase lock-in amplifier, and is also consistent with the software dual phase-locking algorithm.