We report a case of an asymptomatic 36-year-old man with a bronchial artery aneurysm in the right hilum. Selective angiography revealed a 25mmsaccular aneurysm and an efferent artery of the aneurysm forming a high flo...We report a case of an asymptomatic 36-year-old man with a bronchial artery aneurysm in the right hilum. Selective angiography revealed a 25mmsaccular aneurysm and an efferent artery of the aneurysm forming a high flow bronchial artery-pulmonary artery fistula. Because of dilatation and tortuosity of the bronchial artery, the microcatheter could reach the efferent artery but not the fistula. Therefore, we embolized the fistula by sending microcoils through the bloodstream from the efferent artery to the fistula (the “flow-dependent” coil embolization technique), and further embolized the aneurysm by coil isolation and packing technique.展开更多
The optically based technique of electro-optic (EO) sampling has been used for diagnosing the internal high-speed signals of integrated circuits.One of the features that make the EO sampling technique very promising i...The optically based technique of electro-optic (EO) sampling has been used for diagnosing the internal high-speed signals of integrated circuits.One of the features that make the EO sampling technique very promising is a minimal probe: the EO sampling technique does not require an electrode and ground plane incorporated as part of a probe so that, compared with conventional metal probes, the invasiveness of an EO probe is minimal.展开更多
文摘We report a case of an asymptomatic 36-year-old man with a bronchial artery aneurysm in the right hilum. Selective angiography revealed a 25mmsaccular aneurysm and an efferent artery of the aneurysm forming a high flow bronchial artery-pulmonary artery fistula. Because of dilatation and tortuosity of the bronchial artery, the microcatheter could reach the efferent artery but not the fistula. Therefore, we embolized the fistula by sending microcoils through the bloodstream from the efferent artery to the fistula (the “flow-dependent” coil embolization technique), and further embolized the aneurysm by coil isolation and packing technique.
文摘The optically based technique of electro-optic (EO) sampling has been used for diagnosing the internal high-speed signals of integrated circuits.One of the features that make the EO sampling technique very promising is a minimal probe: the EO sampling technique does not require an electrode and ground plane incorporated as part of a probe so that, compared with conventional metal probes, the invasiveness of an EO probe is minimal.