A method using carboxymethyl-b-cyclodextrin (CM-b-CD) as selector for chiral separation of amino acids by capillary electrophoresis and laser-induced fluorescence detection was studied. Resolution was better than tha...A method using carboxymethyl-b-cyclodextrin (CM-b-CD) as selector for chiral separation of amino acids by capillary electrophoresis and laser-induced fluorescence detection was studied. Resolution was better than that obtained by b-CD or HP-b-CD.展开更多
This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary ele...This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary electrophoresis(CE) coupled with laser-induced fluorescence(LIF) detector.Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition.The assay had a wide range(2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL.The intra- and inter-day precisions were satisfactory with relative standard deviation(RSD) less than 10.0%and accuracy within 10.0%.This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood.展开更多
文摘A method using carboxymethyl-b-cyclodextrin (CM-b-CD) as selector for chiral separation of amino acids by capillary electrophoresis and laser-induced fluorescence detection was studied. Resolution was better than that obtained by b-CD or HP-b-CD.
基金supported by the National Natural Science Foundation of China(No30470886)
文摘This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary electrophoresis(CE) coupled with laser-induced fluorescence(LIF) detector.Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition.The assay had a wide range(2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL.The intra- and inter-day precisions were satisfactory with relative standard deviation(RSD) less than 10.0%and accuracy within 10.0%.This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood.