期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
磁控胶囊内镜在儿童再发性腹痛中的诊断价值 被引量:1
1
作者 程伟伟 顾竹珺 +3 位作者 汪星 冯玉灵 张海军 刘海峰 《中国内镜杂志》 2023年第1期71-76,共6页
目的探讨磁控胶囊内镜在儿童再发性腹痛(RAP)中的应用价值。方法回顾性分析2021年1月-2021年6月上海交通大学医学院附属儿童医院内镜中心125例行磁控胶囊内镜检查的RAP患儿的临床资料,分析镜下病变检出情况和胶囊内镜在消化道各部位运... 目的探讨磁控胶囊内镜在儿童再发性腹痛(RAP)中的应用价值。方法回顾性分析2021年1月-2021年6月上海交通大学医学院附属儿童医院内镜中心125例行磁控胶囊内镜检查的RAP患儿的临床资料,分析镜下病变检出情况和胶囊内镜在消化道各部位运行时间等。结果125例患者中,35例拟行全小肠检查(1例因吞服失败而未完成),90例在磁控条件下行食管及胃部检查。磁控胶囊内镜在食管内的中位运行时间为8.5 (5.3,12.5) s,在胃内的中位运行时间为49.0 (17.7,94.0) min,行全小肠检查的患儿,胶囊内镜在小肠内的中位运行时间为252.0 (192.5,340.0) min,全小肠检查完成率为97.1%(34/35),检查完成后所有胶囊内镜均顺利排出体外。上消化道病变检出率为71.8%(89/124),小肠病变检出率为68.6%(24/35)。磁控胶囊内镜对儿童RAP的总体病变检出率为73.4%(91/124)。结论磁控胶囊内镜在RAP患儿胃肠道病变检查中有较高的病变检出率,且安全无痛苦,具有一定的临床应用价值。 展开更多
关键词 磁控胶囊内镜 腹痛 小肠 诊断
下载PDF
Association between late gadolinium enhancement and outcome in dilated cardiomyopathy:A meta-analysis
2
作者 Xin-Yi feng Wen-feng He +5 位作者 Tian-Yue Zhang Ling-Li Wang Fan Yang yu-ling feng Chun-Ping Li Rui Li 《World Journal of Radiology》 2023年第11期324-337,共14页
BACKGROUND The prognostic value of late gadolinium enhancement(LGE)derived from cardiovascular magnetic resonance(CMR)is well studied,and several new metrics of LGE have emerged.However,some controversies remain;there... BACKGROUND The prognostic value of late gadolinium enhancement(LGE)derived from cardiovascular magnetic resonance(CMR)is well studied,and several new metrics of LGE have emerged.However,some controversies remain;therefore,further discussion is needed,and more precise risk stratification should be explored.AIM To investigate the associations between the positivity,extent,location,and pattern of LGE and multiple outcomes in dilated cardiomyopathy(DCM).METHODS PubMed,Ovid MEDLINE,and Cochrane Library were searched for studies that investigated the prognostic value of LGE in patients with DCM.Pooled hazard ratios(HRs)and 95%confidence intervals were calculated to assess the role of LGE in the risk stratification of DCM.RESULTS Nineteen studies involving 7330 patients with DCM were included in this metaanalysis and covered a wide spectrum of DCM,with a mean left ventricular ejection fraction between 21%and 50%.The meta-analysis revealed that the presence of LGE was associated with an increased risk of multiple adverse outcomes(all-cause mortality,HR:2.14;arrhythmic events,HR:5.12;and composite endpoints,HR:2.38;all P<0.001).Furthermore,every 1%increment in the extent of LGE was associated with an increased risk of all-cause mortality.Analysis of a subgroup revealed that the prognostic value varied based on different location and pattern of LGE.Additionally,we found that LGE was a stronger predictor of arrhythmic events in patients with greater left ventricular ejection fraction.CONCLUSION LGE by CMR in patients with DCM exhibited a substantial value in predicting adverse outcomes,and the extent,location,and pattern of LGE could provide additional information for risk stratification. 展开更多
关键词 Cardiac magnetic resonance Dilated cardiomyopathy Late gadolinium enhancement META-ANALYSIS Myocardial fibrosis PROGNOSIS
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部