期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Methods for obtaining characteristic γ-ray net peak count from interlaced overlap peak in HPGe γ-ray spectrometer system 被引量:2
1
作者 yue-li song Feng-Qun Zhou +2 位作者 Yong Li Xiao-Jun Sun Peng-Fei Ji 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第1期73-78,共6页
For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, t... For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, two new methods are proposed herein to obtain the γ-ray net peak count from the interlaced overlap peak in the HPGe cray spectrometer system, of which one is the symmetric conversion method based on Gaussian distribution and the other is where the energy average value of two close γ-rays is regarded as the γ-ray energy. The experimental results indicate that the two methods mentioned above are reliable and credible. This study is significant for the development of better γ-ray spectrum processing software for measuring complex γ-ray spectra concerning the nuclear reaction cross section, neutron activation analysis, and analysis of transuranium elements, using an HPGe detector. 展开更多
关键词 PEAK COUNT Interlaced OVERLAP PEAK Highpurity germanium (HPGe)γ-ray SPECTROMETER system
下载PDF
Exciton emissions of CdS nanowire array fabricated on Cd foil by the solvothermal method
2
作者 李勇 姬鹏飞 +3 位作者 郝亚娟 宋月丽 周丰群 袁书卿 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第1期369-373,共5页
Nanowires have recently attracted more attention because of their low-dimensional structure, tunable optical and electrical properties for next-generation nanoscale optoelectronic devices. Cd S nanowire array, which i... Nanowires have recently attracted more attention because of their low-dimensional structure, tunable optical and electrical properties for next-generation nanoscale optoelectronic devices. Cd S nanowire array, which is(002)-orientation growth and approximately perpendicular to Cd foil substrate, has been fabricated by the solvothermal method. In the temperature-dependent photoluminescence, from short wavelength to long wavelength, four peaks can be ascribed to the emissions from the bandgap, the transition from the holes being bound to the donors or the electrons being bound to the acceptors, the transition from Cd interstitials to Cd vacancies, and the transition from S vacancies to the valence band,respectively. In the photoluminescence of 10 K, the emission originated from the bandgap appears in the form of multiple peaks. Two stronger peaks and five weaker peaks can be observed. The energy differences of the adjacent peaks are close to 38 me V, which is ascribed to the LO phonon energy of Cd S. For the multiple peaks of bandgap emission, from low energy to high energy, the first, second, and third peaks are contributed to the third-order, second-order, and first-order phonon replica of the free exciton A, respectively;the fourth peak is originated from the free exciton A;the fifth peak is contributed to the first-order phonon replica of the excitons bound to neutral donors;the sixth and seventh peaks are originated from the excitons bound to neutral donors and the light polarization parallel to the c axis of hexagonal Cd S, respectively. 展开更多
关键词 CdS nanowires array solvothermal method PHOTOLUMINESCENCE exciton emissions
下载PDF
CdS/Si nanofilm heterojunctions based on amorphous silicon films:Fabrication,structures,and electrical properties
3
作者 李勇 姬鹏飞 +3 位作者 宋月丽 周丰群 黄宏春 袁书卿 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期385-389,共5页
Shortening the distance between the depletion region and the electrodes to reduce the trapped probability of carriers is a useful approach for improving the performance of heterojunction.The CdS/Si nanofilm heterojunc... Shortening the distance between the depletion region and the electrodes to reduce the trapped probability of carriers is a useful approach for improving the performance of heterojunction.The CdS/Si nanofilm heterojunctions are fabricated by using the radio frequency magnetron sputtering method to deposit the amorphous silicon nanofilms and Cd S nanofilms on the ITO glass in turn.The relation of current density to applied voltage(I-V)shows the obvious rectification effect.From the analysis of the double logarithm I-V curve it follows that below~2.73 V the electron behaviors obey the Ohmic mechanism and above~2.73 V the electron behaviors conform to the space charge limited current(SCLC)mechanism.In the SCLC region part of the traps between the Fermi level and conduction band are occupied,and with the increase of voltage most of the traps are occupied.It is believed that Cd S/Si nanofilm heterojunction is a potential candidate in the field of nano electronic and optoelectronic devices by optimizing its fabricating procedure. 展开更多
关键词 magnetron sputtering CdS/Si nanofilm heterojunctions electron behaviors SCLC mechanisms
下载PDF
Measurements of the Cross-sections of Produced Short-Lived Nuclei Induced by Neutrons around 14 MeV on Isotopes of Tungsten
4
作者 孙小军 周丰群 +3 位作者 宋月丽 李勇 姬鹏飞 畅心怡 《Chinese Physics Letters》 SCIE CAS CSCD 2019年第11期10-13,共4页
New experimental cross-section data for the^180 W(n,2 n)^179 mW,^186 W(n,2 n)185 mW and186 W(n,p)186 Ta reactions at the neutron energies of 13.5 and 14.4 MeV are obtained by the activation technique. The neutron beam... New experimental cross-section data for the^180 W(n,2 n)^179 mW,^186 W(n,2 n)185 mW and186 W(n,p)186 Ta reactions at the neutron energies of 13.5 and 14.4 MeV are obtained by the activation technique. The neutron beams are produced by means of the3 H(d,n)4 He reaction. The gamma activities of the product nuclei are measured by a high-resolution gamma-ray spectrometer with a coaxial high-purity germanium detector. The neutron fluence is determined using the monitor reaction^93 Nb(n,2 n)^92 mNb. The results in the current work are discussed and compared with the measurement results found in the literature. It is shown that these higher accuracy experimental cross-section data around the neutron energy of 14 MeV agree with some previous experimental values from the literature within experimental uncertainties. 展开更多
关键词 technique. reaction. PURITY
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部