Experimental Study on the Effect of Humidification on the Pollution Characteristics of Particulate Matter in the Office 被引量:1
1
作者 yuefen gao Shanshan Nan +1 位作者 Guozhong Zheng Tingting gao 《Journal of Environmental Protection》 2016年第12期1791-1801,共12页
Indoor air quality has a direct impact on human health. Indoor air quality has aroused great concern. This experimental study compares the effects of different water humidification on the indoor particulate pollution ... Indoor air quality has a direct impact on human health. Indoor air quality has aroused great concern. This experimental study compares the effects of different water humidification on the indoor particulate pollution characteristics, and analyzes the mass concentration and the particulate number concentration distribution of different sizes of particulates with time under each condition of the purified water humidification, the tap water humidification and the cold boiled water humidification in the office. The results show that under the three kinds of wetting conditions, the concentration of the fine particulates is higher. More minerals are contained in the tap water and the cold boiled water, so the two kinds of humidification have more significant impact on indoor particulate matter. But the purified water humidification has nearly no significant effect on it. The calcium and magnesium ionic compounds are partly removed after the water boiled, so the cold boiled water humidification has less impact on the indoor particulate matter than the tap water humidification. The mass concentration and particulate number concentration of the particle may also be affected due to the frequency of ultrasonic vibration. 展开更多
关键词 HUMIDIFICATION Particulate Matter Pollution Characteristics Particulate Mass Concentration Particulate Number Concentration
下载PDF
Analysis of Thermodynamic Characteristic Changes in Direct Expansion Ground Source Heat Pump Using Hydrofluoroolefins (HFOs) Substituting for HFC-134a
2
作者 yuefen gao Honglei Zhao +1 位作者 Yingxin Peng Tony Roskilly 《Energy and Power Engineering》 2013年第2期11-17,共7页
HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be ... HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be beneficial to mitigating climate change. This study aims to find out the thermodynamic characteristics of the direct expansion ground source heat pump system using HFO-1234yf or HFO-1234ze[E] by theoretical calculation. The results indicate that HFO-1234yf system in an actual cycle has the highest COP. HFO-1234yf and HFO-1234ze[E] have such smaller capacity per unit of swept volume that they need larger compression capacity if providing the same heating or cooling loads. For a given unit when HFC-134a is replaced with HFO-1234yf or HFO-1234ze[E], the capacity will decrease. More refrigerant charge is required in the HFO-1234yf or HFO-1234ze[E] system. The results also present that more refrigerant charge is required in the cooling mode than in the heating mode. 展开更多
关键词 Direct EXPANSION Ground Source Heat PUMP (DXGSHP) THERMODYNAMIC Performance HFO-1234YF HFO-1234ze[E] HFC-134A
下载PDF
Comprehensive Benefit Analysis of Direct Expansion Ground Source Heat Pump System
3
作者 yuefen gao Yingxin Peng Juanjuan Liu 《Energy and Power Engineering》 2013年第2期76-81,共6页
Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary ... Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary loop Ground Couple Heat Pump (GCHP) system, it has higher energy efficiency, lower operating costs, and less environmental impact. A case study is carried out in this paper. The subject is a residential building located in Beijing, China. It is assumed that the building adopts the DXGSHP system and the GCHP system respectively. Annual loads and energy consumption are simulated and computed. Then the initial cost, operating cost and CO2 emission are calculated. The economic benefit is analyzed with the Payback Time method and the Dynamic Annual Cost Value method. The environmental benefit is discussed mainly by comparing the CO2 emission savings. The results show that the DXGSHP system has higher initial costs, but lower operating costs, and less greenhouse gas emissions. The DXGSHP system has better comprehensive benefits than the GCHP system. 展开更多
关键词 Direct EXPANSION GROUND Source Heat PUMP ECONOMIC BENEFIT ENVIRONMENTAL BENEFIT