The research progress of an E//B neutral particle analyzer 被引量:1
1
作者 马龙 屈玉凡 +12 位作者 罗圆 谢德豪 汪彦熹 王硕 曲国峰 任培培 罗小兵 刘星泉 韩纪锋 Roy WADA 林炜平 臧临阁 朱敬军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期10-16,共7页
An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of ... An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV. 展开更多
关键词 E//B neutral particle analyzer gas stripping lutetium-yttrium oxyorthosilicate electron cyclotron resonance ion source platform
下载PDF
Design of the stripping unit and the electromagnetic analysis unit for the E//B NPA on HL-2A/2M tokamak 被引量:1
2
作者 Linge ZANG yufan qu +1 位作者 Yuan LUO Weiping LIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第6期7-13,共7页
An E//B neutral particle analyzer is under development for fast ion diagnosis on HL-2A/2 M tokamak.The stripping unit is composed of a stripping room(equipped with two differential tubes and a gas supply bellows),a va... An E//B neutral particle analyzer is under development for fast ion diagnosis on HL-2A/2 M tokamak.The stripping unit is composed of a stripping room(equipped with two differential tubes and a gas supply bellows),a vacuum chamber and a vacuum pumping system.The stripping efficiency of the stripping room is calculated in the form of global efficiency R×f_(+1),where R is the non-scattered-away rate and f_(+1)is the fraction of charge state+1.The magnetic field of the E//B analyzer is produced with a permanent magnet.The yoke and the poles of the magnet are made of mild steel and the magnet plates are made of Nd Fe B.The magnetic poles are specially designed to focus the ion trajectories and to increase the use rate of the magnet.The shape of the magnet and the electric plates are carefully designed so that the ions are dispersed into two lines of H^(+) and D^(+) on the detector plane.For each line,the energy increases from 10 to 200 ke V from one side to another. 展开更多
关键词 fast ion stripping room particle trajectory neutral particle analysis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部